Linearity of high‐Tc dc superconducting quantum interference device operated in a flux‐locked loop

Measurements have been made of the linearity of a high transition temperature dc superconducting quantum interference device (SQUID) operated at 77 K with 130 kHz flux modulation in a flux‐locked loop. The degree of nonlinearity was determined from harmonic generation. A sinusoidal magnetic flux with harmonic content less than −130 dB was applied to the SQUID, which was cooled in a magnetic field below 10−7 T, and the harmonics at the output of the flux‐locked loop were measured with a spectrum analyzer. For input signals at frequencies up to 248 Hz and amplitudes up to 20Φ0 rms (Φ0 is the flux quantum), the second, third, and fourth harmonics were each at least 115 dB below the fundamental. At higher frequencies the harmonic content began to increase because of the reduction in the open‐loop gain of the flux‐locked loop. The magnitude of the harmonics was not measurably changed when the SQUID was cooled in a field of 100 μT. The amplitudes of the even harmonics depended critically on the amplitude of the...

[1]  John Clarke,et al.  Addendum: ‘‘Low noise YBa2Cu3O7−x‐SrTiO3‐YBa2Cu3O7−x multilayers for improved superconducting magnetometers’’ [Appl. Phys. Lett. 66, 373 (1995)] , 1995 .

[2]  D. Drung,et al.  A 5‐MHz bandwidth SQUID magnetometer with additional positive feedback , 1995 .

[3]  R. Cantor,et al.  Low‐noise YBa2Cu3O7−δ direct‐current superconducting quantum interference device magnetometer with direct signal injection , 1995 .

[4]  E. Sodtke,et al.  Single layer YBa2Cu3O7 radio frequency SQUID magnetometers with direct‐coupled pickup coils and flip‐chip flux transformers , 1994 .

[5]  C. Heiden,et al.  A YBa/sub 2/Cu/sub 3/O/sub 7/ thin film SQUID gradiometer for measurements in unshielded space , 1993, IEEE Transactions on Applied Superconductivity.

[6]  Dietmar Drung,et al.  Low‐noise high‐speed dc superconducting quantum interference device magnetometer with simplified feedback electronics , 1990 .

[7]  John Clarke,et al.  Integrated dc SQUID magnetometer with a high slew rate , 1984 .

[8]  John Clarke,et al.  Flicker (1/f) noise in tunnel junction dc SQUIDS , 1983 .

[9]  J. Waldram,et al.  Superconducting Quantum Interference Devices and their Applications , 1982 .

[10]  John Clarke,et al.  Tunnel junction dc SQUID: Fabrication, operation, and performance , 1976 .

[11]  J. Zimmerman,et al.  MINIATURE ULTRASENSITIVE SUPERCONDUCTING MAGNETIC GRADIOMETER AND ITS USE IN CARDIOGRAPHY AND OTHER APPLICATIONS. , 1971 .

[12]  A. Warnick,et al.  Digital‐Analog Magnetometer Utilizing Superconducting Sensor , 1967 .

[13]  D. Pascal,et al.  Effect of noise on the performance of rf SQUID magnetometers , 1979 .