Kinematic analysis of a 5-DOF hybrid-driven MR compatible robot for minimally invasive prostatic interventions

This paper introduces the design and kinematic analysis of a 5-DOF (multiple degree of freedom) hybrid-driven MR (Magnetic Resonance) compatible robot for prostate brachytherapy. It can slip the leash of template and rely on the high precise of MR imaging. After a brief introduction on design requirements of MR compatible robot, a description of our robot structure, material selection, hybrid-driven, and control architecture are presented. Secondly, the forward kinematics equations are obtained according to the equivalent diagram of this robot, and the actual workspace can be outlined. This will help the designer to determine whether this robot can be operated in the MR core without intervention with patient. And then, the inverse kinematics equations combined with trajectory planning are used to calculate the actuators movement. This will help the control system to manipulate the robotic accurately. Finally, vision based experiments on phantoms are used to verify the mechanism precision. As the results shown, the needle tip precision of mechanism is 0.9 mm in the general lab environment.

[1]  B. Carey,et al.  Imaging for prostate cancer. , 2005, Clinical oncology (Royal College of Radiologists (Great Britain)).

[2]  Robert Chasnov,et al.  Design and Optimization , 2013 .

[3]  G.S. Fischer,et al.  Design of a Robot for Transperineal Prostate Needle Placement in MRI Scanner , 2006, 2006 IEEE International Conference on Mechatronics.

[4]  Jian S. Dai Surgical robotics and its development and progress , 2010, Robotica.

[5]  Alexandru Patriciu,et al.  “MRI Stealth” robot for prostate interventions , 2007, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.

[6]  A. Tornes,et al.  A new brachytherapy seed design for improved ultrasound visualization , 2003, IEEE Symposium on Ultrasonics, 2003.

[7]  Ching-Shiow Tseng,et al.  Development of an image-guided robotic system for surgical positioning and drilling , 2007, Robotica.

[8]  Michael A. Meltsner Design and optimization of a brachytherapy robot , 2007 .

[9]  Septimiu E. Salcudean,et al.  A robotic needle guide for prostate brachytherapy , 2008, 2008 IEEE International Conference on Robotics and Automation.

[10]  N. Hata,et al.  Needle Insertion Simulation for Image-Guided Brachytherapy of Prostate Cancer , 2008, 2008 2nd International Conference on Bioinformatics and Biomedical Engineering.

[11]  Robert J. Wood,et al.  Towards a 3g crawling robot through the integration of microrobot technologies , 2006, Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006..

[12]  Yongde Zhang,et al.  Robot-Assisted Prostate Brachytherapy , 2006, MICCAI.

[13]  A. Jemal,et al.  Cancer Statistics, 2009 , 2009, CA: a cancer journal for clinicians.

[14]  Nobuhiko Hata,et al.  Magnetic Resonance-guided Prostate Interventions , 2005, Topics in magnetic resonance imaging : TMRI.

[15]  Rajnikant V. Patel,et al.  A Novel Manipulator for 3D Ultrasound Guided Percutaneous Needle Insertion , 2007, Proceedings 2007 IEEE International Conference on Robotics and Automation.

[16]  Masoom A. Haider,et al.  Robot-assisted MRI-guided prostatic interventions , 2009, Robotica.

[17]  H. Hricak,et al.  Imaging prostate cancer. , 1999, The Journal of urology.

[18]  R. Taschereau,et al.  Seed misplacement and stabilizing needles in transperineal permanent prostate implants. , 2000, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[19]  Gabor Fichtinger,et al.  Development of a pneumatic robot for MRI-guided transperineal prostate biopsy and brachytherapy: New approaches , 2010, 2010 IEEE International Conference on Robotics and Automation.

[20]  Kenneth Y. Goldberg,et al.  Sensorless Motion Planning for Medical Needle Insertion in Deformable Tissues , 2009, IEEE Transactions on Information Technology in Biomedicine.

[21]  Gabor Fichtinger,et al.  Design of a novel MRI compatible manipulator for image guided prostate interventions , 2005, IEEE Transactions on Biomedical Engineering.

[22]  Tianmiao Wang,et al.  A hybrid robot system for CT-guided surgery , 2010, Robotica.

[23]  Qiang Huang,et al.  An ultrasound-directed robotic system for microwave ablation of liver cancer , 2009, Robotica.

[24]  N. Dubrawsky Cancer statistics , 1989, CA: a cancer journal for clinicians.

[25]  Liyong Lin,et al.  The use of directional interstitial sources to improve dosimetry in breast brachytherapy. , 2007, Medical physics.

[26]  Cho-Pei Jiang,et al.  Investigation on Occlusion Effect of Tumor Vessel in HIFU Surgery , 2009, 2009 2nd International Conference on Biomedical Engineering and Informatics.

[27]  Xiaoyan Liu,et al.  3D Trajectory Planning Based on FEM with Application of Brachytherapy , 2009, 2009 2nd International Conference on Biomedical Engineering and Informatics.