Vaginocutaneous fistula: A rare long-term complication of transobturator tape procedure for stress urinary incontinence

Introduction: Synthetic mid-urethral slings are currently the most common performed surgical procedure for the treatment of female stress urinary incontinence. The transobturator mid-urethral sling technique has been widely accepted owing to its high success and low complication rates. Although complications are rarely seen, it may cause significant morbidity. Case presentation: We report a case of vaginocutaneous fistula following transobturator mid-urethral sling procedure and a successful reconstruction with transvaginal sling excision and fistula closure. Conclusion: Vaginocutaneous fistula is a known but rarely seen long-term complication of transobturator tape. With an increased use of mesh, various delayed complications can be seen in the long-term follow-up. This case showed us the need for longer and detailed studies that evaluate the effectiveness and safety of the transobturator tape procedure.