Corrosion monitoring in archives by the electrical resistance technique

Abstract It is essential that corrosion monitoring of indoor atmospheres should be highly sensitive, especially, when corrosion rates corresponding to the lowest standard corrosivity categories are supposed to be identified within one or a few days. The electrical resistance technique in combination with high-sensitivity electrical resistance sensors enabled detection of a corrosion loss on an atomic scale. Case studies have demonstrated the sensors’ ability to timely inform the users about changes in the atmosphere quality. In confrontation with quartz crystal microbalance technique, resistometric sensors provided better explainable data.

[1]  M. McKenzie,et al.  Use of weight loss coupons and electrical resistance probes in atmospheric corrosion tests , 1985 .

[2]  A. Pacheco,et al.  An investigation of the dependence of atmospheric corrosion rate on temperature using printed-circuit iron cells , 1994 .

[3]  M. Kouřil,et al.  Real time corrosion monitoring in atmosphere using automated battery driven corrosion loggers , 2008 .

[4]  Carl Johan Bergsten,et al.  Atmospheric corrosion of historical organ pipes: The influence of environment and materials , 2008 .

[5]  C. Leygraf,et al.  Studies of Corrosion Kinetics on Electrical Contact Materials by Means of Quartz Crystal Microbalance and XPS , 1986 .

[6]  T. Shinohara,et al.  Evaluation of Corrosivity in Atmospheric Environment by ACM (Atmospheric Corrosion Monitor) Type Corrosion Sensor , 2005 .

[7]  C. Watt,et al.  Acetic and formic acids emitted from wood samples and their effect on selected materials in museum environments , 2010 .

[8]  Michel Dubus,et al.  Monitoring Copper and Silver Corrosion in Different Museum Environments by Electrical Resistance Measurement , 2010 .

[9]  Wataru Oshikawa,et al.  Fractal behavior of galvanic current of dual electrode type of atmospheric corrosion monitor , 1999 .

[10]  E. Sacchi,et al.  Air Quality Monitoring at Historic Sites: Redefining an Environmental Classification System for Gaseous Pollution , 2005 .

[11]  T. Prošek,et al.  Application of automated corrosion sensors for monitoring the rate of corrosion during accelerated corrosion tests , 2014 .

[12]  M. Ryhl-Svendsen Corrosivity measurements of indoor museum environments using lead coupons as dosimeters , 2008 .

[13]  M. Itagaki,et al.  Three-electrode type micro-electrochemical cell fabricated by screen-printing , 2011 .

[14]  Christofer Leygraf Atmospheric corrosion , 2000 .