Flexible cardiac T1 mapping using a modified look–locker acquisition with saturation recovery

A modified Look–Locker acquisition using saturation recovery (MLLSR) for breath‐held myocardial T1 mapping is presented. Despite its reduced dynamic range, saturation recovery enables substantially higher imaging efficiency than conventional inversion recovery T1 mapping because it does not require time for magnetization to relax to equilibrium. Therefore, MLLSR enables segmented readouts, shorter data acquisition windows, and shorter breath holds compared with inversion recovery. T1 measurements in phantoms using MLLSR showed a high correlation with conventional single‐point inversion recovery spin echo. In vivo T1 measurements from normal and infarcted myocardium in 41 volunteers and patients were consistent with previously reported values. Twenty subjects were also scanned with MLLSR using an accelerated sampling scheme that required half the scan time (eight vs. 16 heartbeats) but yielded equivalent results. The flexibility afforded by the improved imaging efficiency of MLLSR allows the acquisition to be tailored to particular clinical needs and to individual patient's breath‐holding abilities. Magn Reson Med, 2012. © 2011 Wiley Periodicals, Inc.

[1]  Stefan Neubauer,et al.  Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold , 2010, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[2]  E. Fleck,et al.  The influence of myocardial blood flow and volume of distribution on late Gd‐DTPA kinetics in ischemic heart failure , 2004, Journal of magnetic resonance imaging : JMRI.

[3]  A. Crawley,et al.  A comparison of one‐shot and recovery methods in T1 imaging , 1988, Magnetic resonance in medicine.

[4]  David M Higgins,et al.  Modified Look‐Locker inversion recovery (MOLLI) for high‐resolution T1 mapping of the heart , 2004, Magnetic resonance in medicine.

[5]  Katherine C. Wu,et al.  Infarct Tissue Heterogeneity by Magnetic Resonance Imaging Identifies Enhanced Cardiac Arrhythmia Susceptibility in Patients With Left Ventricular Dysfunction , 2007, Circulation.

[6]  Prediction of myocardial signal during CINE balanced SSFP imaging , 2010, Magnetic Resonance Materials in Physics, Biology and Medicine.

[7]  Sandeep N. Gupta,et al.  Evaluation of diffuse myocardial fibrosis in heart failure with cardiac magnetic resonance contrast-enhanced T1 mapping. , 2008, Journal of the American College of Cardiology.

[8]  V. Ho,et al.  Contrast agents: innovations and potential applications for body MR angiography. , 2005, Magnetic resonance imaging clinics of North America.

[9]  Andreas Greiser,et al.  Optimization and validation of a fully‐integrated pulse sequence for modified look‐locker inversion‐recovery (MOLLI) T1 mapping of the heart , 2007, Journal of magnetic resonance imaging : JMRI.

[10]  F S Prato,et al.  A novel fast T1‐mapping method , 1994, Journal of magnetic resonance imaging : JMRI.

[11]  M. Griswold,et al.  Inversion recovery TrueFISP: Quantification of T1, T2, and spin density , 2004, Magnetic resonance in medicine.

[12]  R. Falk,et al.  Cardiovascular magnetic resonance in cardiac amyloidosis. , 2005, Circulation.

[13]  David M Higgins,et al.  Human myocardium: single-breath-hold MR T1 mapping with high spatial resolution--reproducibility study. , 2006, Radiology.

[14]  R. Kim,et al.  Reproducibility of Chronic Infarct Size Measurement by Contrast-Enhanced Magnetic Resonance Imaging , 2002, Circulation.

[15]  J. Schulz-Menger,et al.  T1 mapping in patients with acute myocardial infarction. , 2003, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[16]  Quantitative breath‐hold monitoring of myocardial gadolinium enhancement using inversion recovery TrueFISP , 2005, Magnetic resonance in medicine.

[17]  M. Friedrich There is more than shape and function. , 2008, Journal of the American College of Cardiology.

[18]  A. Haase,et al.  Quantification of regional blood volumes by rapid T1 mapping , 1993, Magnetic resonance in medicine.

[19]  Mark Griswold,et al.  Rapid T1 mapping of mouse myocardium with saturation recovery look‐locker method , 2010, Magnetic resonance in medicine.

[20]  J. Ridgway,et al.  Myocardial T1 mapping for detection of left ventricular myocardial fibrosis in chronic aortic regurgitation: pilot study. , 2006, AJR. American journal of roentgenology.

[21]  Klaus Scheffler,et al.  On the transient phase of balanced SSFP sequences , 2003, Magnetic resonance in medicine.

[22]  M. Bock,et al.  Changes in myocardial oxygenation and perfusion under pharmacological stress with dipyridamole: Assessment using T*2 and T1 measurements , 1999, Magnetic resonance in medicine.

[23]  Reza Razavi,et al.  Interleaved T1 and T2 relaxation time mapping for cardiac applications , 2009, Journal of magnetic resonance imaging : JMRI.

[24]  N. Oesingmann,et al.  Single breath‐hold T1 measurement using low flip angle TrueFISP , 2006, Magnetic resonance in medicine.

[25]  P L Carson,et al.  Determination of sample time for T1 measurement , 1998, Journal of magnetic resonance imaging : JMRI.

[26]  S. Plein,et al.  Myocardial T1 mapping: Application to patients with acute and chronic myocardial infarction , 2007, Magnetic resonance in medicine.

[27]  J Hennig,et al.  T1 quantification with inversion recovery TrueFISP , 2001, Magnetic resonance in medicine.