LQXB05 test report
暂无分享,去创建一个
In the first test cycle, MQXB11 quenched at 12236 A (221 T/m{sup 1}) and at 12974 A (233T/m). MQXB08 quenched at 12922 (233 T/m) Quench training results are compared to previous magnets in Fig. 1. Table 1 is a list of quenches executed as part of quench current studies. Additional quenches were done to study the ramp rated dependence of the quench current.