Point of Care Technologies for HIV

Effective prevention of HIV/AIDS requires early diagnosis, initiation of therapy, and regular plasma viral load monitoring of the infected individual. In addition, incidence estimation using accurate and sensitive assays is needed to facilitate HIV prevention efforts in the public health setting. Therefore, more affordable and accessible point-of-care (POC) technologies capable of providing early diagnosis, HIV viral load measurements, and CD4 counts in settings where HIV is most prevalent are needed to enable appropriate intervention strategies and ultimately stop transmission of the virus within these populations to achieve the future goal of an AIDS-free generation. This review discusses the available and emerging POC technologies for future application to these unmet public health needs.

[1]  D. Malamud,et al.  Detection of Human Immunodeficiency Virus Antibodies in Oral Fluids , 1998, Clinical Diagnostic Laboratory Immunology.

[2]  M. Pandori,et al.  Assessment of the Ability of a Fourth-Generation Immunoassay for Human Immunodeficiency Virus (HIV) Antibody and p24 Antigen To Detect both Acute and Recent HIV Infections in a High-Risk Setting , 2009, Journal of Clinical Microbiology.

[3]  Shuqi Chen,et al.  A rapid and automated sample-to-result HIV load test for near-patient application. , 2010, The Journal of infectious diseases.

[4]  R. Abramson,et al.  Detection of specific polymerase chain reaction product by utilizing the 5'----3' exonuclease activity of Thermus aquaticus DNA polymerase. , 1991, Proceedings of the National Academy of Sciences of the United States of America.

[5]  Z. Fox,et al.  Comparative Evaluation of the ExaVir Load Version 3 Reverse Transcriptase Assay for Measurement of Human Immunodeficiency Virus Type 1 Plasma Load , 2009, Journal of Clinical Microbiology.

[6]  Obi L. Griffith,et al.  HIV Sequence Database , 2014 .

[7]  A. Fire,et al.  Rolling replication of short DNA circles. , 1995, Proceedings of the National Academy of Sciences of the United States of America.

[8]  A. Taratorin,et al.  Magnetic Information Storage Technology , 1999 .

[9]  B. Weber Screening of HIV infection: role of molecular and immunological assays , 2006, Expert review of molecular diagnostics.

[10]  P. Chavez,et al.  Evaluation of the performance of the Abbott ARCHITECT HIV Ag/Ab Combo Assay. , 2011, Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology.

[11]  P. Lizardi,et al.  Mutation detection and single-molecule counting using isothermal rolling-circle amplification , 1998, Nature Genetics.

[12]  Charles Poole,et al.  Rethinking the heterosexual infectivity of HIV-1: a systematic review and meta-analysis. , 2008, The Lancet. Infectious diseases.

[13]  Yi Guan,et al.  Sensitive and inexpensive molecular test for falciparum malaria: detecting Plasmodium falciparum DNA directly from heat-treated blood by loop-mediated isothermal amplification. , 2006, Clinical chemistry.

[14]  David E. Williams,et al.  Point of care diagnostics: status and future. , 2012, Analytical chemistry.

[15]  R. Holzman,et al.  Human Immunodeficiency Virus (HIV) Reverse Transcriptase Activity Correlates with HIV RNA Load: Implications for Resource-Limited Settings , 2005, Journal of Clinical Microbiology.

[16]  C. Brennan,et al.  Evaluation of the sensitivity and specificity of six HIV combined p24 antigen and antibody assays. , 2004, Journal of virological methods.

[17]  T. Notomi,et al.  Loop-mediated isothermal amplification of DNA. , 2000, Nucleic acids research.

[18]  Yoshihide Hayashizaki,et al.  Tail variation of the folding primer affects the SmartAmp2 process differently. , 2009, Biochemical and biophysical research communications.

[19]  L. Laursen Point-of-care tests poised to alter course of HIV treatment , 2012, Nature Medicine.

[20]  J. Justin Gooding,et al.  Recent Advances in Paper-Based Sensors , 2012, Sensors.

[21]  Bo Liedberg,et al.  Silane-dextran chemistry on lateral flow polymer chips for immunoassays. , 2008, Lab on a chip.

[22]  S. Buttò,et al.  Laboratory diagnostics for HIV infection. , 2010, Annali dell'Istituto superiore di sanita.

[23]  Piia von Lode,et al.  Point-of-care immunotesting: approaching the analytical performance of central laboratory methods. , 2005, Clinical biochemistry.

[24]  R. Salamon,et al.  Field Evaluation of an Improved Assay Using a Heat‐Dissociated p24 Antigen for Adults Mainly Infected With HIV‐1 CRF02_AG Strains in Côte d’Ivoire, West Africa , 2003, Journal of acquired immune deficiency syndromes.

[25]  G. Learn,et al.  HIV-1 Nomenclature Proposal , 2000, Science.

[26]  B. Deiman,et al.  Characteristics and applications of nucleic acid sequence-based amplification (NASBA) , 2002, Molecular biotechnology.

[27]  Mehmet Toner,et al.  A Microchip Approach for Practical Label-Free CD4+ T-Cell Counting of HIV-Infected Subjects in Resource-Poor Settings , 2007, Journal of acquired immune deficiency syndromes.

[28]  R Zachariah,et al.  Viewpoint: Why do we need a point‐of‐care CD4 test for low‐income countries? , 2011, Tropical medicine & international health : TM & IH.

[29]  Feng Xu,et al.  Advances in developing HIV-1 viral load assays for resource-limited settings. , 2010, Biotechnology advances.

[30]  Chong H. Ahn,et al.  Potential of a simple lab-on-a-tube for point-of-care measurements of multiple analytes. , 2010, Lab on a chip.

[31]  Olaf Piepenburg,et al.  DNA Detection Using Recombination Proteins , 2006, PLoS biology.

[32]  S. Crowe,et al.  Evaluation of the Cavidi ExaVir Load Assay (Version 3) for Plasma Human Immunodeficiency Virus Type 1 Load Monitoring , 2009, Journal of Clinical Microbiology.

[33]  B. Branson The Future of HIV Testing , 2010, Journal of acquired immune deficiency syndromes.

[34]  Paul LaBarre,et al.  Isothermal Amplification Using a Chemical Heating Device for Point-of-Care Detection of HIV-1 , 2012, PloS one.

[35]  Carsten O. Daub,et al.  Optimization of turn-back primers in isothermal amplification , 2011, 2011 IEEE International Conference on Bioinformatics and Biomedicine Workshops (BIBMW).

[36]  Yongqiang Cheng,et al.  Ultrasensitive detection of microRNAs by exponential isothermal amplification. , 2010, Angewandte Chemie.

[37]  H. Craighead,et al.  Micro- and nanomechanical sensors for environmental, chemical, and biological detection. , 2007, Lab on a chip.

[38]  S. Kalichman,et al.  Approaching "HIV elimination": Interventions for acute HIV infection , 2006, Current HIV/AIDS reports.

[39]  M. Zaman,et al.  Low-cost tools for diagnosing and monitoring HIV infection in low-resource settings. , 2012, Bulletin of the World Health Organization.

[40]  D. Shank,et al.  Isothermal in vitro amplification of DNA by a restriction enzyme/DNA polymerase system. , 1992, Proceedings of the National Academy of Sciences of the United States of America.

[41]  S. Liska,et al.  Performance evaluation of the Bio-Rad Laboratories GS HIV Combo Ag/Ab EIA, a 4th generation HIV assay for the simultaneous detection of HIV p24 antigen and antibodies to HIV-1 (groups M and O) and HIV-2 in human serum or plasma. , 2011, Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology.

[42]  Alex Rhee,et al.  Facile and rapid one-step mass preparation of quantum-dot barcodes. , 2008, Angewandte Chemie.

[43]  Daniel Malamud,et al.  An isothermal amplification reactor with an integrated isolation membrane for point-of-care detection of infectious diseases. , 2011, The Analyst.

[44]  T. Notomi,et al.  Accelerated reaction by loop-mediated isothermal amplification using loop primers. , 2002, Molecular and cellular probes.

[45]  P. Hartigan,et al.  Changes in plasma HIV-1 RNA and CD4+ lymphocyte counts and the risk of progression to AIDS. Veterans Affairs Cooperative Study Group on AIDS. , 1996, The New England journal of medicine.

[46]  Cassandra Willyard Simpler tests for immune cells could transform AIDS care in Africa , 2007, Nature Medicine.

[47]  Bernard P. Puc,et al.  An integrated semiconductor device enabling non-optical genome sequencing , 2011, Nature.

[48]  Utkan Demirci,et al.  Efficient on-chip isolation of HIV subtypes. , 2012, Lab on a chip.

[49]  B. Castelnuovo,et al.  Evaluation of Portable Point-of-Care CD4 Counter with High Sensitivity for Detecting Patients Eligible for Antiretroviral Therapy , 2012, PloS one.

[50]  Adam L. Washburn,et al.  Quantitative, label-free detection of five protein biomarkers using multiplexed arrays of silicon photonic microring resonators. , 2010, Analytical chemistry.

[51]  Organización Mundial de la Salud,et al.  Towards universal access: scaling up priority HIV/AIDS interventions in the health sector. Progress report 2009 , 2009 .

[52]  Marco Schito,et al.  Opportunities and challenges for cost-efficient implementation of new point-of-care diagnostics for HIV and tuberculosis. , 2012, The Journal of infectious diseases.

[53]  Ronald Laborde,et al.  Rapid detection of HIV-1 p24 antigen using magnetic immuno-chromatography (MICT). , 2009, Journal of virological methods.

[54]  Molly M Stevens,et al.  Plasmonic ELISA for the ultrasensitive detection of disease biomarkers with the naked eye. , 2012, Nature nanotechnology.

[55]  Evan R Hirst,et al.  Bond-rupture immunosensors--a review. , 2008, Biosensors & bioelectronics.

[56]  Gi Hun Seong,et al.  Microfluidic chips for immunoassays. , 2013, Annual review of analytical chemistry.

[57]  Eiichi Honda,et al.  Colorimetric detection of loop-mediated isothermal amplification reaction by using hydroxy naphthol blue. , 2009, BioTechniques.

[58]  D. D'Souza,et al.  Multiplex Nucleic Acid Sequence-Based Amplification for Simultaneous Detection of Several Enteric Viruses in Model Ready-To-Eat Foods , 2004, Applied and Environmental Microbiology.

[59]  H. Kong,et al.  Application of isothermal helicase-dependent amplification with a disposable detection device in a simple sensitive stool test for toxigenic Clostridium difficile. , 2008, The Journal of molecular diagnostics : JMD.

[60]  U. Unicef,et al.  Global HIV/AIDS response: epidemic update and health sector progress towards universal access: progress report 2011. , 2011 .

[61]  Investigation of the molecular mechanism of ICAN, a novel gene amplification method. , 2007, Journal of biochemistry.

[62]  Yasuyoshi Mori,et al.  Sequence specific visual detection of LAMP reactions by addition of cationic polymers. , 2006, BMC biotechnology.

[63]  Jacques Schrenzel,et al.  Robustness of a loop-mediated isothermal amplification reaction for diagnostic applications. , 2011, FEMS immunology and medical microbiology.

[64]  Mats Nilsson,et al.  Homogeneous amplified single-molecule detection: Characterization of key parameters. , 2007, Analytical biochemistry.

[65]  Stephen R Cole,et al.  Timing of initiation of antiretroviral therapy in AIDS-free HIV-1-infected patients: a collaborative analysis of 18 HIV cohort studies , 2009, The Lancet.

[66]  L. van Damme,et al.  Performance of a Rapid and Simple HIV Testing Algorithm in a Multicenter Phase III Microbicide Clinical Trial , 2011, Clinical and Vaccine Immunology.

[67]  K. Sepkowitz,et al.  AIDS--the first 20 years. , 2001, The New England journal of medicine.

[68]  R. Gascoyne,et al.  A novel method of amplification of FFPET-derived RNA enables accurate disease classification with microarrays. , 2010, The Journal of molecular diagnostics : JMD.

[69]  T. Peter,et al.  Accurate CD4 T-cell enumeration and antiretroviral drug toxicity monitoring in primary healthcare clinics using point-of-care testing , 2011, AIDS.

[70]  Yoshihide Hayashizaki,et al.  Rapid SNP diagnostics using asymmetric isothermal amplification and a new mismatch-suppression technology , 2007, Nature Methods.

[71]  G. Whitesides,et al.  Diagnostics for the developing world: microfluidic paper-based analytical devices. , 2010, Analytical chemistry.

[72]  Niko Hildebrandt,et al.  Toward sensitive, quantitative point-of-care testing (POCT) of protein markers: miniaturization of a homogeneous time-resolved fluoroimmunoassay for prostate-specific antigen detection. , 2011, The Analyst.

[73]  Martina Blažková,et al.  Development of a nucleic acid lateral flow immunoassay for simultaneous detection of Listeria spp. and Listeriamonocytogenes in food , 2009 .

[74]  Haluk Kulah,et al.  CMOS Cell Sensors for Point-of-Care Diagnostics , 2012, Sensors.

[75]  Thomas Schalkhammer,et al.  From Lateral Flow Devices to a Novel Nano-Color Microfluidic Assay , 2009, Sensors.

[76]  G. Schochetman,et al.  Seven Human Immunodeficiency Virus (HIV) Antigen-Antibody Combination Assays: Evaluation of HIV Seroconversion Sensitivity and Subtype Detection , 2001, Journal of Clinical Microbiology.

[77]  David J. Galas,et al.  Isothermal reactions for the amplification of oligonucleotides , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[78]  Xiaowei Guo Surface plasmon resonance based biosensor technique: A review , 2012, Journal of biophotonics.

[79]  T. Yoshikawa,et al.  Heat denaturation increases the sensitivity of the cytomegalovirus loop‐mediated isothermal amplification method , 2010, Microbiology and immunology.

[80]  B. Stilwell,et al.  Antiretroviral therapy for HIV infection in adults and adolescents: recommendations for a public health approach. 2006 revision. , 2006 .

[81]  Chao Ma,et al.  A self-powered, one-step chip for rapid, quantitative and multiplexed detection of proteins from pinpricks of whole blood. , 2010, Lab on a chip.

[82]  S. Luchters,et al.  Evaluation of two commercially available alternatives for HIV-1 viral load testing in resource-limited settings. , 2007, Journal of virological methods.

[83]  Andrea Vidali,et al.  Improved multiple displacement amplification with phi29 DNA polymerase for genotyping of single human cells. , 2008, BioTechniques.

[84]  P. Craw,et al.  Isothermal nucleic acid amplification technologies for point-of-care diagnostics: a critical review. , 2012, Lab on a chip.

[85]  Ronald F Renzi,et al.  An integrated microfluidic platform for sensitive and rapid detection of biological toxins. , 2008, Lab on a chip.

[86]  Thomas Otto,et al.  Highly-integrated lab-on-chip system for point-of-care multiparameter analysis. , 2012, Lab on a chip.

[87]  A. Berger,et al.  Multicenter Evaluation of a New Automated Fourth-Generation Human Immunodeficiency Virus Screening Assay with a Sensitive Antigen Detection Module and High Specificity , 2002, Journal of Clinical Microbiology.

[88]  B. Chohan,et al.  Evaluation of a single round polymerase chain reaction assay using dried blood spots for diagnosis of HIV-1 infection in infants in an African setting , 2011, BMC pediatrics.

[89]  Carlo Petrini,et al.  Informed consent in experimentation involving mentally impaired persons: ethical issues. , 2010, Annali dell'Istituto superiore di sanita.

[90]  B. Branson State of the art for diagnosis of HIV infection. , 2007, Clinical infectious diseases : an official publication of the Infectious Diseases Society of America.

[91]  I. Kato,et al.  Highly efficient isothermal DNA amplification system using three elements of 5'-DNA-RNA-3' chimeric primers, RNaseH and strand-displacing DNA polymerase. , 2007, Journal of biochemistry.

[92]  Veronica Leautaud,et al.  A Lateral Flow Assay for Quantitative Detection of Amplified HIV-1 RNA , 2012, PloS one.

[93]  H Tanke,et al.  Use of up-converting phosphor reporters in lateral-flow assays to detect specific nucleic acid sequences: a rapid, sensitive DNA test to identify human papillomavirus type 16 infection. , 2001, Clinical chemistry.

[94]  P. Volberding,et al.  Antiretroviral therapy and management of HIV infection , 2010, The Lancet.

[95]  U. Landegren,et al.  Signal amplification of padlock probes by rolling circle replication. , 1998, Nucleic acids research.

[96]  P. Mercié,et al.  [AIDS--the first 20 years]. , 2001, La Revue de medecine interne.

[97]  C. Aitken,et al.  HIV testing--the perspective from across the pond. , 2011, Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology.

[98]  D. Rudolph,et al.  Sequence‐specific detection method for reverse transcription, loop‐mediated isothermal amplification of HIV‐1 , 2009, Journal of medical virology.

[99]  Takehiko Kitamori,et al.  A micro-ELISA system for the rapid and sensitive measurement of total and specific immunoglobulin E and clinical application to allergy diagnosis. , 2009, Lab on a chip.

[100]  J. L. Raina,et al.  Factors underlying spontaneous inactivation and susceptibility to neutralization of human immunodeficiency virus. , 1992, Virology.

[101]  J. Fox,et al.  Low rates of p24 antigen detection using a fourth-generation point of care HIV test , 2010, Sexually Transmitted Infections.

[102]  Guo-Jun Zhang,et al.  Silicon nanowire biosensor and its applications in disease diagnostics: a review. , 2012, Analytica chimica acta.

[103]  K Watanabe,et al.  Loop-mediated isothermal amplification reaction using a nondenatured template. , 2001, Clinical chemistry.

[104]  Ke Chen,et al.  An electrochemical stripping metalloimmunoassay based on silver-enhanced gold nanoparticle label. , 2005, Biosensors & bioelectronics.

[105]  H. Lang,et al.  Multiple label-free biodetection and quantitative DNA-binding assays on a nanomechanical cantilever array , 2002, Proceedings of the National Academy of Sciences of the United States of America.

[106]  [Development of the detection system for Mycobacterium tuberculosis DNA by using the isothermal DNA amplification method ICAN]. , 2002, Rinsho byori. The Japanese journal of clinical pathology.

[107]  Adriano Lazzarin,et al.  Offer of rapid testing and alternative biological samples as practical tools to implement HIV screening programs. , 2009, The new microbiologica.

[108]  S. Laperche,et al.  Could the new HIV combined p24 antigen and antibody assays replace p24 antigen specific assays? , 2007, Journal of virological methods.

[109]  Marc Madou,et al.  Present technology and future trends in point-of-care microfluidic diagnostics. , 2013, Methods in molecular biology.

[110]  Y. Mori,et al.  Detection of loop-mediated isothermal amplification reaction by turbidity derived from magnesium pyrophosphate formation. , 2001, Biochemical and biophysical research communications.

[111]  C. Beck-Sague,et al.  Diagnosis of Human Immunodeficiency Virus Type 1 Infection in Infants by Use of Dried Blood Spots and an Ultrasensitive p24 Antigen Assay , 2008, Journal of Clinical Microbiology.

[112]  K. Fransen,et al.  Evaluation of a rapid and simple fourth-generation HIV screening assay for qualitative detection of HIV p24 antigen and/or antibodies to HIV-1 and HIV-2. , 2010, Journal of virological methods.

[113]  C. Fossum,et al.  Development of an in situ assay for simultaneous detection of the genomic and replicative form of PCV2 using padlock probes and rolling circle amplification , 2011, Virology Journal.

[114]  Michael P Busch,et al.  Challenges for rapid molecular HIV diagnostics. , 2010, The Journal of infectious diseases.

[115]  C. Rouzioux,et al.  The measurement of HIV-1 viral load in resource-limited settings: how and where? , 2007, Clinical laboratory.

[116]  D. Rudolph,et al.  Rapid detection of HIV-1 by reverse-transcription, loop-mediated isothermal amplification (RT-LAMP). , 2008, Journal of virological methods.

[117]  Haitao Yu,et al.  Nanogram per milliliter-level immunologic detection of alpha-fetoprotein with integrated rotating-resonance microcantilevers for early-stage diagnosis of heptocellular carcinoma , 2009, Biomedical microdevices.

[118]  Julio S. G. Montaner,et al.  CD4+ T-Cell Count Monitoring Does Not Accurately Identify HIV-Infected Adults With Virologic Failure Receiving Antiretroviral Therapy , 2008, Journal of acquired immune deficiency syndromes.

[119]  M F Burritt,et al.  Point-of-care testing. , 1995, Mayo Clinic proceedings.

[120]  Aart van Amerongen,et al.  Molecular diagnosis of malaria in the field: development of a novel 1-step nucleic acid lateral flow immunoassay for the detection of all 4 human Plasmodium spp. and its evaluation in Mbita, Kenya. , 2008, Diagnostic microbiology and infectious disease.

[121]  P. Hsieh,et al.  Identification and Characterization of a Thermostable MutS Homolog from Thermus aquaticus(*) , 1996, The Journal of Biological Chemistry.

[122]  Yan Xu,et al.  Helicase‐dependent isothermal DNA amplification , 2004, EMBO reports.

[123]  Yasuyoshi Mori,et al.  Real-time turbidimetry of LAMP reaction for quantifying template DNA. , 2004, Journal of biochemical and biophysical methods.

[124]  Indira Hewlett,et al.  Nanoparticle-based immunoassays for sensitive and early detection of HIV-1 capsid (p24) antigen. , 2010, The Journal of infectious diseases.

[125]  M. Fowler,et al.  Infant human immunodeficiency virus diagnosis in resource-limited settings: issues, technologies, and country experiences. , 2007, American journal of obstetrics and gynecology.

[126]  S. Reynolds,et al.  OraQuick® ADVANCE Rapid HIV-1/2 antibody test , 2004, Expert review of molecular diagnostics.

[127]  Gyu-Hyeong Cho,et al.  An autonomous CMOS hysteretic sensor for the detection of desorption-free DNA hybridization. , 2011, Biosensors & bioelectronics.

[128]  D. Cliffel,et al.  Electrochemical sensors and biosensors. , 2012, Analytical chemistry.

[129]  María-Isabel Rocha-Gaso,et al.  Surface Generated Acoustic Wave Biosensors for the Detection of Pathogens: A Review , 2009, Sensors.

[130]  Trevor Peter,et al.  Evaluation of the PIMA Point-of-Care CD4 Analyzer in VCT Clinics in Zimbabwe , 2010, Journal of acquired immune deficiency syndromes.

[131]  G. Leroux-Roels,et al.  Vaccine-induced HIV seropositivity: a problem on the rise. , 2011, Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology.

[132]  Michael A. Brook,et al.  Design of Gold Nanoparticle‐Based Colorimetric Biosensing Assays , 2008, Chembiochem : a European journal of chemical biology.

[133]  Aydogan Ozcan,et al.  Integrated rapid-diagnostic-test reader platform on a cellphone. , 2012, Lab on a chip.

[134]  R. Holzman,et al.  Monitoring Virologic Responses to Antiretroviral Therapy in HIV-Infected Adults in Kenya: Evaluation of a Low-Cost Viral Load Assay , 2009, PloS one.

[135]  David S Boyle,et al.  Emerging technologies for point-of-care CD4 T-lymphocyte counting. , 2012, Trends in biotechnology.

[136]  R. Elghanian,et al.  p24 Antigen Rapid Test for Diagnosis of Acute Pediatric HIV Infection , 2010, Journal of acquired immune deficiency syndromes.

[137]  L. Gervais,et al.  Toward one-step point-of-care immunodiagnostics using capillary-driven microfluidics and PDMS substrates. , 2009, Lab on a chip.

[138]  W. Seitz,et al.  Immunoassay labels based on chemiluminescence and bioluminescence. , 1984, Clinical biochemistry.

[139]  Mehmet Toner,et al.  Cell detection and counting through cell lysate impedance spectroscopy in microfluidic devices. , 2007, Lab on a chip.

[140]  Bo Mattiasson,et al.  Ultrasensitive detection of HIV-1 p24 antigen using nanofunctionalized surfaces in a capacitive immunosensor. , 2010, Analytical chemistry.

[141]  W. Stevens,et al.  Performance evaluation of the Pima™ point-of-care CD4 analyser using capillary blood sampling in field tests in South Africa , 2012, Journal of the International AIDS Society.

[142]  Alberto Escarpa,et al.  Electrochemical immunosensing on board microfluidic chip platforms , 2012 .

[143]  G. Walker,et al.  Strand displacement amplification--an isothermal, in vitro DNA amplification technique. , 1992, Nucleic acids research.