Reliability and Agreement of 3D Trunk and Lower Extremity Movement Analysis by Means of Inertial Sensor Technology for Unipodal and Bipodal Tasks

This study evaluates the reliability and agreement of the 3D range of motion (ROM) of trunk and lower limb joints, measured by inertial measurement units (MVN BIOMECH Awinda, Xsens Technologies), during a single leg squat (SLS) and sit to stand (STS) task. Furthermore, distinction was made between movement phases, to discuss the reliability and agreement for different phases of both movement tasks. Twenty healthy participants were measured on two testing days. On day one, measurements were conducted by two operators to determine the within-session and between-operator reliability and agreement. On day two, measurements were conducted by the same operator, to determine the between-session reliability and agreement. The SLS task had lower within-session reliability and agreement compared with between-session and between-operator reliability and agreement. The reliability and agreement of the hip, knee, and ankle ROM in the sagittal plane were good for both phases of the SLS task. For both phases of STS task, within-session reliability and agreement were good, and between-session and between-operator reliability and agreement were lower in all planes. As both tasks are physically demanding, differences may be explained by inconsistent movement strategies. These results show that inertial sensor systems show promise for use in further research to investigate (mal)adaptive movement strategies.

[1]  P. Veltink,et al.  Estimating orientation with gyroscopes and accelerometers. , 1999, Technology and health care : official journal of the European Society for Engineering and Medicine.

[2]  Michael A Hunt,et al.  Gait modification strategies for altering medial knee joint load: A systematic review , 2011, Arthritis care & research.

[3]  Peter H. Veltink,et al.  Ambulatory Position and Orientation Tracking Fusing Magnetic and Inertial Sensing , 2007, IEEE Transactions on Biomedical Engineering.

[4]  Thomas Seel,et al.  User-Adaptive Inertial Sensor Network for Feedback-Controlled Gait Support Systems , 2016 .

[5]  Katia Turcot,et al.  Sit-to-stand alterations in advanced knee osteoarthritis. , 2012, Gait & posture.

[6]  A Forner-Cordero,et al.  Study of the motion artefacts of skin-mounted inertial sensors under different attachment conditions , 2008, Physiological measurement.

[7]  Andrew J Harrison,et al.  Functional data analysis of running kinematics in chronic Achilles tendon injury. , 2008, Medicine and science in sports and exercise.

[8]  Hartmut Witte,et al.  ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion--part I: ankle, hip, and spine. International Society of Biomechanics. , 2002, Journal of biomechanics.

[9]  Carlos Dias Maciel,et al.  Test-retest reliability of three-dimensional kinematics using an electromagnetic tracking system during single-leg squat and stepping maneuver. , 2014, Gait & posture.

[10]  I Jonkers,et al.  Mobile assessment of the lower limb kinematics in healthy persons and in persons with degenerative knee disorders: A systematic review. , 2018, Gait & posture.

[11]  Thomas Seel,et al.  Exploiting kinematic constraints to compensate magnetic disturbances when calculating joint angles of approximate hinge joints from orientation estimates of inertial sensors , 2017, 2017 International Conference on Rehabilitation Robotics (ICORR).

[12]  Bertram Taetz,et al.  Towards self-calibrating inertial body motion capture , 2016, 2016 19th International Conference on Information Fusion (FUSION).

[13]  Christian Larue,et al.  Accuracy and repeatability of single-pose calibration of inertial measurement units for whole-body motion analysis. , 2017, Gait & posture.

[14]  N Verdonschot,et al.  How to quantify knee function after total knee arthroplasty? , 2008, The Knee.

[15]  D. Roetenberg,et al.  Xsens MVN: Full 6DOF Human Motion Tracking Using Miniature Inertial Sensors , 2009 .

[16]  Johan Bellemans,et al.  Functional movement assessment by means of inertial sensor technology to discriminate between movement behaviour of healthy controls and persons with knee osteoarthritis , 2020, Journal of NeuroEngineering and Rehabilitation.

[17]  J. Weir Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM. , 2005, Journal of strength and conditioning research.

[18]  Christian Larue,et al.  Validation of inertial measurement units with an optoelectronic system for whole-body motion analysis , 2017, Medical & Biological Engineering & Computing.

[19]  Kate Button,et al.  Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity , 2018, Sensors.

[20]  Ilse Jonkers,et al.  Reliability of 3D Lower Extremity Movement Analysis by Means of Inertial Sensor Technology during Transitional Tasks , 2018, Sensors.

[21]  Corina Nüesch,et al.  Measuring joint kinematics of treadmill walking and running: Comparison between an inertial sensor based system and a camera-based system. , 2017, Journal of biomechanics.

[22]  Cornie Scheffer,et al.  Repeatability of an off-the-shelf, full body inertial motion capture system during clinical gait analysis , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[23]  Thomas Seel,et al.  Alignment-free, self-calibrating elbow angles measurement using inertial sensors , 2017, 2016 IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI).

[24]  Cara L Lewis,et al.  NOT ALL SINGLE LEG SQUATS ARE EQUAL: A BIOMECHANICAL COMPARISON OF THREE VARIATIONS. , 2016, International journal of sports physical therapy.

[25]  Annick Timmermans,et al.  Within/between-session reliability and agreement of lumbopelvic kinematics in the sagittal plane during functional movement control tasks in healthy persons. , 2017, Musculoskeletal science & practice.

[26]  I Jonkers,et al.  Discriminant validity of 3D joint kinematics and centre of mass displacement measured by inertial sensor technology during the unipodal stance task , 2020, PloS one.

[27]  Thomas B. Schön,et al.  An optimization-based approach to human body motion capture using inertial sensors , 2014 .

[28]  J. Fleiss,et al.  Intraclass correlations: uses in assessing rater reliability. , 1979, Psychological bulletin.