Investigation of viability of plant tissue in the environmental scanning electron microscopy

The advantages of environmental scanning electron microscopy (ESEM) make it a suitable technique for studying plant tissue in its native state. There have been few studies on the effects of ESEM environment and beam damage on the viability of plant tissue. A simple plant tissue, Allium cepa (onion) upper epidermal tissue was taken as the model for study. The change of moisture content of samples was studied at different relative humidities. Working with the electron beam on, viability tests were conducted for samples after exposure in the ESEM under different operating conditions to investigate the effect of electron beam dose on the viability of samples. The results suggested that without the electron beam, the ESEM chamber itself can prevent the loss of initial moisture if its relative humidity is maintained above 90%. With the electron beam on, the viability of Allium cepa (onion) cells depends both on the beam accelerating voltage and the electron dose/unit area hitting the sample. The dose can be controlled by several of the ESEM instrumental parameters. The detailed process of beam damage on cuticle-down and cuticle-up samples was investigated and compared. The results indicate that cuticular adhesion to the cell wall is relatively weak, but highly resistant to electron beam damage. Systematic study on the effect of ESEM operation parameters has been done. Results qualitatively support the intuitive expectations, but demonstrate quantitatively that Allium cepa epidermal cells are able to be kept in a hydrated and viable state under relevant operation condition inside ESEM, providing a basis for further in situ experiments on plant tissues.

[1]  D E H Tee,et al.  Book Review: Culture of Animal Cells: A Manual of Basic Technique , 1984 .

[2]  W. M. Haynes CRC Handbook of Chemistry and Physics , 1990 .

[3]  A. Donald,et al.  Amplification measurements of alternative imaging gases in environmental SEM , 1997 .

[4]  Antonio Giordano,et al.  A critical overview of ESEM applications in the biological field , 2005, Journal of cellular physiology.

[5]  A. Donald,et al.  Fracture of plant tissues and walls as visualized by environmental scanning electron microscopy. , 2003, Annals of botany.

[6]  V. Robinson,et al.  Principles of scanning electron microscopy at high specimen chamber pressures , 1979 .

[7]  A. Donald,et al.  The use of environmental scanning electron microscopy for imaging wet and insulating materials , 2003, Nature Materials.

[8]  W. Bonfield,et al.  Electron microscopy of mammalian cells in the absence of fixing, freezing, dehydration, or specimen coating. , 2006, Scanning.

[9]  A. Donald,et al.  In situ Mechanical Testing of Fully Hydrated Carrots (Daucus carota) in the Environmental SEM , 1998 .

[10]  G. W. Tautfest,et al.  Faraday-Cup Monitors for High-Energy Electron Beams , 1956 .

[11]  A. Donald,et al.  Use of the environmental scanning electron microscope for the observation of the swelling behaviour of cellulosic fibres , 2006 .

[12]  G. Danilatos Introduction to the ESEM instrument , 1993, Microscopy research and technique.

[13]  Debbie J Stokes,et al.  Recent advances in electron imaging, image interpretation and applications: environmental scanning electron microscopy , 2003, Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences.

[14]  B. Thiel,et al.  Radiation damage of water in environmental scanning electron microscopy , 2001, Journal of microscopy.

[15]  G. Danilatos Foundations of Environmental Scanning Electron Microscopy , 1988 .

[16]  Benjamin Geiger,et al.  Organization and adhesive properties of the hyaluronan pericellular coat of chondrocytes and epithelial cells. , 2003, Biophysical journal.

[17]  Kitching,et al.  Beam damage of polypropylene in the environmental scanning electron microscope: an FTIR study , 1998 .

[18]  W. Horwitz Official Methods of Analysis , 1980 .

[19]  R. C. Weast CRC Handbook of Chemistry and Physics , 1973 .

[20]  D. Sandberg,et al.  Material damage due to electron beam during testing in the environmental scanning electron microscope (ESEM). , 2000 .