A Model of the Upper Extremity for Simulating Musculoskeletal Surgery and Analyzing Neuromuscular Control

Biomechanical models of the musculoskeletal system are frequently used to study neuromuscular control and simulate surgical procedures. To be broadly applicable, a model must be accessible to users, provide accurate representations of muscles and joints, and capture important interactions between joints. We have developed a model of the upper extremity that includes 15 degrees of freedom representing the shoulder, elbow, forearm, wrist, thumb, and index finger, and 50 muscle compartments crossing these joints. The kinematics of each joint and the force-generating parameters for each muscle were derived from experimental data. The model estimates the muscle–tendon lengths and moment arms for each of the muscles over a wide range of postures. Given a pattern of muscle activations, the model also estimates muscle forces and joint moments. The moment arms and maximum moment-generating capacity of each muscle group (e.g., elbow flexors) were compared to experimental data to assess the accuracy of the model. These comparisons showed that moment arms and joint moments estimated using the model captured important features of upper extremity geometry and mechanics. The model also revealed coupling between joints, such as increased passive finger flexion moment with wrist extension. The computer model is available to researchers at http://nmbl.stanford.edu.

[1]  A. Engin,et al.  Active muscle torques about long-bone axes of major human joints. , 1980, Aviation, space, and environmental medicine.

[2]  D. Dowson,et al.  Analysis of elbow forces due to high-speed forearm movements. , 1980, Journal of biomechanics.

[3]  J. London Kinematics of the elbow. , 1981, The Journal of bone and joint surgery. American volume.

[4]  R. L. Linscheid,et al.  Muscles across the elbow joint: a biomechanical analysis. , 1981, Journal of biomechanics.

[5]  K. An,et al.  Tendon excursion and moment arm of index finger muscles. , 1983, Journal of biomechanics.

[6]  N. Curtin,et al.  Energetic aspects of muscle contraction. , 1985, Monographs of the Physiological Society.

[7]  K. L. Moore,et al.  Clinically Oriented Anatomy , 1985 .

[8]  P. Helm Clinical mechanics of the hand , 1986 .

[9]  R. L. Linscheid,et al.  Relative motion of selected carpal bones: a kinematic analysis of the normal wrist. , 1988, The Journal of hand surgery.

[10]  John T. McConville,et al.  Anthropometric Survey of U.S. Army Personnel: Methods and Summary Statistics 1988 , 1989 .

[11]  F. Zajac Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control. , 1989, Critical reviews in biomedical engineering.

[12]  Claire C. Gordon,et al.  2012 Anthropometric Survey of U.S. Army Personnel: Methods and Summary Statistics , 2014 .

[13]  R. Lieber,et al.  Architecture of selected wrist flexor and extensor muscles. , 1990, The Journal of hand surgery.

[14]  T. Santner,et al.  Torque production in the shoulder of the normal young adult male , 1990, The American journal of sports medicine.

[15]  F.E. Zajac,et al.  An interactive graphics-based model of the lower extremity to study orthopaedic surgical procedures , 1990, IEEE Transactions on Biomedical Engineering.

[16]  R. Lieber,et al.  Architectural design of the human intrinsic hand muscles. , 1992, The Journal of hand surgery.

[17]  L. M. Myers,et al.  The axes of rotation of the thumb carpometacarpal joint , 1992, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[18]  R. Lieber,et al.  Architecture of selected muscles of the arm and forearm: anatomy and implications for tendon transfer. , 1992, The Journal of hand surgery.

[19]  J. Winters,et al.  Effect of initial upper-limb alignment on muscle contributions to isometric strength curves. , 1993, Journal of biomechanics.

[20]  F. V. D. van der Helm A finite element musculoskeletal model of the shoulder mechanism. , 1994, Journal of biomechanics.

[21]  T. Santner,et al.  Changes in the moment arms of the rotator cuff and deltoid muscles with abduction and rotation. , 1994, The Journal of bone and joint surgery. American volume.

[22]  F.C.T. van der Helm,et al.  A finite element musculoskeletal model of the shoulder mechanism. , 1994 .

[23]  L. M. Myers,et al.  The axes of rotation of the thumb interphalangeal and metacarpophalangeal joints. , 1995, Clinical orthopaedics and related research.

[24]  S L Delp,et al.  A graphics-based software system to develop and analyze models of musculoskeletal structures. , 1995, Computers in biology and medicine.

[25]  T. Buchanan Evidence that maximum muscle stress is not a constant: differences in specific tension in elbow flexors and extensors. , 1995, Medical engineering & physics.

[26]  S. Delp,et al.  Variation of muscle moment arms with elbow and forearm position. , 1995, Journal of biomechanics.

[27]  D. A. Shreeve,et al.  An evaluation of optimization techniques for the prediction of muscle activation patterns during isometric tasks. , 1996, Journal of biomechanical engineering.

[28]  S. Delp,et al.  Maximum isometric moments generated by the wrist muscles in flexion-extension and radial-ulnar deviation. , 1996, Journal of biomechanics.

[29]  J. Fridén,et al.  Human wrist motors: biomechanical design and application to tendon transfers. , 1996, Journal of biomechanics.

[30]  P. Crago,et al.  A dynamic model for simulating movements of the elbow, forearm, an wrist. , 1996, Journal of biomechanics.

[31]  P. Crago,et al.  Restoration of pronosupination control by FNS in tetraplegia--experimental and biomechanical evaluation of feasibility. , 1996, Journal of biomechanics.

[32]  K. An,et al.  Shoulder muscle moment arms during horizontal flexion and elevation. , 1997, Journal of shoulder and elbow surgery.

[33]  S. Delp,et al.  How muscle architecture and moment arms affect wrist flexion-extension moments. , 1997, Journal of biomechanics.

[34]  W. Smutz,et al.  Roles of deltoid and rotator cuff muscles in shoulder elevation. , 1997, Clinical biomechanics.

[35]  K. An,et al.  Comparison of two methods for computing abduction moment arms of the rotator cuff. , 1997, Journal of biomechanics.

[36]  S. Delp,et al.  Muscular resistance to varus and valgus loads at the elbow. , 1998, Journal of biomechanical engineering.

[37]  K. An,et al.  Mechanical advantage of the thumb muscles. , 1998, Journal of biomechanics.

[38]  A. Herrmann,et al.  Moment arm and force-generating capacity of the extensor carpi ulnaris after transfer to the extensor carpi radialis brevis. , 1999, The Journal of hand surgery.

[39]  S. Delp,et al.  The isometric functional capacity of muscles that cross the elbow. , 2000, Journal of biomechanics.

[40]  P. Crago,et al.  Intrinsic and extrinsic contributions to the passive moment at the metacarpophalangeal joint. , 2000, Journal of biomechanics.

[41]  N Hogan,et al.  Stability in Force-Production Tasks , 2001, Journal of motor behavior.

[42]  J. D. de Groot,et al.  A three-dimensional regression model of the shoulder rhythm. , 2001, Clinical biomechanics.

[43]  S J Piazza,et al.  Three-dimensional dynamic simulation of total knee replacement motion during a step-up task. , 2001, Journal of biomechanical engineering.

[44]  M G Pandy,et al.  Musculoskeletal Model of the Upper Limb Based on the Visible Human Male Dataset , 2001, Computer methods in biomechanics and biomedical engineering.

[45]  N. Fowler,et al.  A biomechanical analysis of the rheumatoid index finger after joint arthroplasty. , 2002, Clinical biomechanics.

[46]  S. Delp,et al.  Scaling of peak moment arms of elbow muscles with upper extremity bone dimensions. , 2002, Journal of biomechanics.

[47]  K. Kilgore,et al.  The Influence of Elbow Position on the Range of Motion of the Wrist Following Transfer of the Brachioradialis to the Extensor Carpi Radialis Brevis Tendon , 2002, The Journal of bone and joint surgery. American volume.

[48]  L. O’Sullivan,et al.  Upper-limb surface electro-myography at maximum supination and pronation torques: the effect of elbow and forearm angle. , 2002, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[49]  Joseph D. Towles,et al.  Towards a realistic biomechanical model of the thumb: the choice of kinematic description may be more critical than the solution method or the variability/uncertainty of musculoskeletal parameters. , 2003, Journal of biomechanics.

[50]  Katherine R. Saul,et al.  Biomechanics of the Steindler flexorplasty surgery: a computer simulation study. , 2003, The Journal of hand surgery.

[51]  D J Giurintano,et al.  A 3D biomechanical model of the hand for power grip. , 2003, Journal of biomechanical engineering.

[52]  R. Hughes,et al.  Musculoskeletal parameters of muscles crossing the shoulder and elbow and the effect of sarcomere length sample size on estimation of optimal muscle length. , 2004, Clinical biomechanics.

[53]  F. V. D. van der Helm,et al.  Effectiveness of tendon transfers for massive rotator cuff tears: a simulation study. , 2004, Clinical biomechanics.

[54]  Bryan Buchholz,et al.  ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion--Part II: shoulder, elbow, wrist and hand. , 2005, Journal of biomechanics.

[55]  Geoffrey H. Sperber,et al.  Clinically Oriented Anatomy , 2006 .