Impact of air velocity, temperature, humidity, and air on long-term voc emissions from building products

Abstract The emissions of two volatile organic compounds (VOCs) of concern from five building products (BPs) were measured in the field and laboratory emission cell (FLEC) up to 250 d. The BPs (VOCs selected on the basis of abundance and low human odor thresholds) were: nylon carpet with latex backing (2-ethylhexanol, 4-phenylcyclohexene), PVC flooring (2-ethylhexanol, phenol), floor varnish on pretreated beechwood parquet (butyl acetate, N-methylpyrrolidone), sealant (hexane, dimethyloctanols), and waterborne wall paint on gypsum board (1,2-propandiol, Texanol). Ten different climate conditions were tested: four different air velocities from ca. 1 cm s -1 to ca. 9 cm s -1 , three different temperatures (23, 35, and 60°C), two different relative humidities (0% and 50% RH), and pure nitrogen instead of clean air supply. Additionally, two sample specimen and two different batches were compared for repeatability and homogeneity. The VOCs were sampled on Tenax TA and determined by thermal desorption and gas chromatography (FID). Quantification was carried out by individual calibration of each VOC of concern. Concentration/time profiles of the selected VOCs (i.e. their concentration decay curves over time) in a standard room were used for comparison. Primary source emissions were not affected by the air velocity after a few days to any great extent. Both the temperature and relative humidity affected the emission rates, but depended strongly on the type of BP and type of VOC. Secondary (oxidative) source emissions were only observed for the PVC and for dimethyloctanols from the sealant. The time to reach a given concentration (emission rate) appears to be a good approach for future interlaboratory comparisons of BP’s VOC emissions.

[1]  Peder Wolkoff,et al.  An emission cell for measurement of volatile organic compounds emitted from building materials for indoor use - the field and laboratory emission cell FLEC , 1996 .

[2]  Peder Wolkoff,et al.  A new approach for indoor climate labeling of building materials—emission testing, modeling, and comfort evaluation☆ , 1996 .

[3]  Zhishi Guo,et al.  Considerations on revisions of emissions testing protocols , 1996 .

[4]  Peder Wolkoff Volatile Organic Compounds Sources, Measurements, Emissions, and the Impact on Indoor Air Quality , 1995 .

[5]  Chris Netten,et al.  Temperature and humidity dependence of formaldehyde release from selected building materials , 1989, Bulletin of environmental contamination and toxicology.

[6]  Per Axel Clausen,et al.  Long‐term Emission of Volatile Organic Compounds from Waterborne Paints – Methods of Comparison , 1991 .

[7]  Peder Wolkoff,et al.  Design and characterization of the CLIMPAQ, chamber for laboratory investigations of materials, pollution and air quality , 1994 .

[8]  Sinks,et al.  Characterizing sources of indoor air pollution and related sink effects , 1996 .

[9]  Van P. Carey,et al.  The properties of gases & liquids: 4th Edition. Robert C. Reid, John M. Prausnitz, and Bruce E. Poling, McGraw-Hill Book Company, New York, NY, 1987, 741 pages, $49.50. , 1988 .

[10]  J. Wal,et al.  The Influence of Temperature on the Emission of Volatile Organic Compounds from PVC flooring, Carpet, and Paint , 1997 .

[11]  J O Westgard,et al.  A multi-rule Shewhart chart for quality control in clinical chemistry. , 1981, Clinical chemistry.

[12]  Charles J. Weschler,et al.  Indoor chemistry. Ozone, volatile organic compounds, and carpets , 1992 .

[13]  Jari Nobrega Cardosa Health Buildings '94: Budapest, Hungary, August 22-25, 1994 , 1994 .

[14]  I. Andersen,et al.  Indoor air pollution due to chipboard used as a construction material , 1975 .

[15]  Peder Wolkoff,et al.  Health-related evaluation of building products based on climate chamber tests , 1994 .

[16]  P. Koutrakis,et al.  Ozone reactive chemistry on interior latex paint. , 1995, Environmental science & technology.

[17]  Peder Wolkoff,et al.  Documentation Of Field And Laboratory Emission Cell “FLEC”: Identification Of Emission Processes From Carpet, Linoleum, Paint, And Sealant By Modeling , 1993 .

[18]  S. Sollinger,et al.  Indoor pollution by organic emissions from textile floor coverings: Climate test chamber studies under static conditions , 1994 .

[19]  Per Axel Clausen,et al.  Application of the Field and Laboratory Emission Cell “FLEC” ‐ Performance Study, Intercomparison Study, and Case Study of Damaged Linoleum in an Office , 1995 .

[20]  N. Irving Sax,et al.  Dangerous properties of industrial materials , 1957 .

[21]  Karsten Levsen,et al.  Indoor air pollution by organic emissions from textile floor coverings. Climate chamber studies under dynamic conditions , 1993 .

[22]  Dermal sensitization potential and inhalation toxicological evaluation of 4-phenylcyclohexene. , 1991, American Industrial Hygiene Association journal.

[23]  Peder Wolkoff,et al.  Field and Laboratory Emission Cell: FLEC , 1991 .

[24]  Peder Wolkoff,et al.  Chemical and Biological Evaluation of Building Material Emissions. II. Approaches for Setting Indoor Air Standards or Guidelines for Chemicals , 1997 .

[25]  N Radin The multi-rule Shewhart chart for quality control. , 1984, Clinical chemistry.

[26]  Peder Wolkoff,et al.  Characterization of Linoleum: Identification of Oxidative Emission Processes , 1996 .

[27]  J. Girman,et al.  Volatile organic compounds and building bake-out. , 1989, Occupational medicine.