Compensation of spectral and RF errors in swept-source OCT for high extinction complex demodulation.

We provide a framework for compensating errors within passive optical quadrature demodulation circuits used in swept-source optical coherence tomography (OCT). Quadrature demodulation allows for detection of both the real and imaginary components of an interference fringe, and this information separates signals from positive and negative depth spaces. To achieve a high extinction (∼60 dB) between these positive and negative signals, the demodulation error must be less than 0.1% in amplitude and phase. It is difficult to construct a system that achieves this low error across the wide spectral and RF bandwidths of high-speed swept-source systems. In a prior work, post-processing methods for removing residual spectral errors were described. Here, we identify the importance of a second class of errors originating in the RF domain, and present a comprehensive framework for compensating both spectral and RF errors. Using this framework, extinctions >60 dB are demonstrated. A stability analysis shows that calibration parameters associated with RF errors are accurate for many days, while those associated with spectral errors must be updated prior to each imaging session. Empirical procedures to derive both RF and spectral calibration parameters simultaneously and to update spectral calibration parameters are presented. These algorithms provide the basis for using passive optical quadrature demodulation circuits with high speed and wide-bandwidth swept-source OCT systems.

[1]  Joseph A. Izatt,et al.  Instantaneous complex conjugate resolved spectral domain OCT using 3⨉3 fiber couplers , 2004 .

[2]  Instantaneous quadrature components or Jones vector retrieval using the Pancharatnam-Berry phase in frequency domain low-coherence interferometry. , 2012, Optics letters.

[3]  R. Leitgeb,et al.  High speed full range complex spectral domain optical coherence tomography. , 2005, Optics express.

[4]  Zhongping Chen,et al.  Real-time phase-resolved functional optical coherence tomography by use of optical Hilbert transformation. , 2002, Optics Letters.

[5]  Benjamin J Vakoc,et al.  A rapid, dispersion-based wavelength-stepped and wavelength-swept laser for optical coherence tomography. , 2014, Optics express.

[6]  A. Fercher,et al.  Full range complex spectral optical coherence tomography technique in eye imaging. , 2002, Optics letters.

[7]  Maciej Wojtkowski,et al.  Complex spectral OCT in human eye imaging in vivo , 2004 .

[8]  S. Yun,et al.  High-speed optical frequency-domain imaging. , 2003, Optics express.

[9]  S. Yun,et al.  Phase-resolved optical frequency domain imaging. , 2005, Optics express.

[10]  S. Yun,et al.  Removing the depth-degeneracy in optical frequency domain imaging with frequency shifting. , 2004, Optics express.

[11]  B E Bouma,et al.  Elimination of depth degeneracy in optical frequency-domain imaging through polarization-based optical demodulation. , 2006, Optics letters.

[12]  A. Fercher,et al.  Phase-shifting algorithm to achieve high-speed long-depth-range probing by frequency-domain optical coherence tomography. , 2003, Optics letters.