Pressure Generation Beneath a New Thermoplastic Cast

A new cast immobilizer that is heat-shrunk to conform to an injured extremity was examined. The purpose of these studies was to compare pressures beneath the thermoplastic cast with those beneath fiberglass casts on a laboratory model and on the forearms of human volunteers. Pressures measured beneath fiberglass casts on metal cylinders averaged 36 mm Hg. Thermoplastic casts on the smaller cylinder that allowed 42% shrinkage produced a mean pressure of 25 mm Hg; those placed on the larger cylinder that allowed 17% shrinkage produced a mean pressure of 39 mm Hg. Pressures measured on the forearms of healthy volunteers averaged 22 mm Hg beneath fiberglass casts and 31 mm Hg beneath the thermoplastic casts. These pressures were considerably less than pressures that have been shown to occlude the microcirculation of the skin. Acute compartment syndromes result from swelling within a limited space and remain a serious concern clinically when swelling is anticipated under any type of constraining cast. The results of these studies indicate that the new cast should not produce a greater risk of circulatory compromise to the limb than previously used fiberglass materials.

[1]  M. Keenan,et al.  Skin Surface Pressures Under Short Leg Casts , 1993, Journal of orthopaedic trauma.

[2]  G. Bowyer,et al.  Pressure in plaster backslabs after surgery for ankle fractures. , 1993, Injury.

[3]  D. Wardlaw,et al.  Intracast pressure measurements in Colles' fractures. , 1991, Injury.

[4]  R. Wytch,et al.  Interface pressures in below elbow casts. , 1991, Clinical biomechanics.

[5]  R. Kenedi Biomechanical highlights--the personal miscellany of a decade. , 1988, Journal of biomedical engineering.

[6]  W. Akeson,et al.  Local compression patterns beneath pneumatic tourniquets applied to arms and thighs of human cadavera , 1987, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[7]  P. Rolfe,et al.  Skin surface PO2 and blood flow measurements over the ischial tuberosity. , 1982, Archives of physical medicine and rehabilitation.

[8]  R. Daniel,et al.  Etiologic factors in pressure sores: an experimental model. , 1981, Archives of physical medicine and rehabilitation.

[9]  B. Levack,et al.  A study of pressures beneath forearm plasters. , 1981, Injury.

[10]  L. Bennett,et al.  Shear vs pressure as causative factors in skin blood flow occlusion. , 1979, Archives of physical medicine and rehabilitation.

[11]  N. Lassen,et al.  On the pathogenesis of bedsores. Skin blood flow cessation by external pressure on the back. , 1979, Scandinavian journal of plastic and reconstructive surgery.