A Data-Driven Modeling Strategy for Smart Grid Power Quality Coupling Assessment Based on Time Series Pattern Matching

This study introduces a data-driven modeling strategy for smart grid power quality (PQ) coupling assessment based on time series pattern matching to quantify the influence of single and integrated disturbance among nodes in different pollution patterns. Periodic and random PQ patterns are constructed by using multidimensional frequency-domain decomposition for all disturbances. A multidimensional piecewise linear representation based on local extreme points is proposed to extract the patterns features of single and integrated disturbance in consideration of disturbance variation trend and severity. A feature distance of pattern (FDP) is developed to implement pattern matching on univariate PQ time series (UPQTS) and multivariate PQ time series (MPQTS) to quantify the influence of single and integrated disturbance among nodes in the pollution patterns. Case studies on a 14-bus distribution system are performed and analyzed; the accuracy and applicability of the FDP in the smart grid PQ coupling assessment are verified by comparing with other time series pattern matching methods.

[1]  Trapti Jain,et al.  Visualizing time-varying power quality indices using generalized empirical wavelet transform , 2017 .

[2]  Mihai Sanduleac,et al.  Syncretic Use of Smart Meters for Power Quality Monitoring in Emerging Networks , 2017, IEEE Transactions on Smart Grid.

[3]  G. Ye,et al.  Harmonic disturbance location by applying Bayesian inference , 2016 .

[4]  Haiyan Dong,et al.  PQ state space representation and its application to electromagnetic compatibility/incompatibility degree, influence degree, and PQ performance assessment , 2016 .

[5]  Jianmin Li,et al.  Detection and Classification of Power Quality Disturbances Using Double Resolution S-Transform and DAG-SVMs , 2016, IEEE Transactions on Instrumentation and Measurement.

[6]  Rongcun Wang,et al.  Empirical Study of the Effects of Different Similarity Measures on Test Case Prioritization , 2016 .

[7]  B. Berg Least square fitting with one explicit parameter less , 2015, Comput. Phys. Commun..

[8]  P. K. Dash,et al.  Robust estimation of power quality disturbances using unscented H∞ filter , 2015 .

[9]  Xiaoqun Ding,et al.  Opposition-Based Improved PSO for Optimal Reactive Power Dispatch and Voltage Control , 2015 .

[10]  D. Mahinda Vilathgamuwa,et al.  A Statistical Evaluation of the Capability of Distributed Renewable Generator-Energy-Storage System in Providing Load Low-Voltage Ride-Through , 2015, IEEE Transactions on Power Delivery.

[11]  Sazali Yaacob,et al.  Improved Emotion Recognition Using Gaussian Mixture Model and Extreme Learning Machine in Speech and Glottal Signals , 2015 .

[12]  Qu Guanglon A Correlation Mining Method for Power Quality Data Based on Trapezoidal Cloud Model , 2015 .

[13]  L. Nayak,et al.  An estimate of the rate of convergence of Fourier series in the generalized Hölder metric by Deferred Cesàro Mean , 2014 .

[14]  Hongsheng Yin,et al.  Generalized Framework for Similarity Measure of Time Series , 2014 .

[15]  Ing-Jr Ding,et al.  An HMM-Like Dynamic Time Warping Scheme for Automatic Speech Recognition , 2014 .

[16]  Mostafa F. Shaaban,et al.  Accommodating High Penetrations of PEVs and Renewable DG Considering Uncertainties in Distribution Systems , 2014, IEEE Transactions on Power Systems.

[17]  Yasser Abdel-Rady I. Mohamed,et al.  Modeling, Analysis, and Stabilization of Converter-Fed AC Microgrids With High Penetration of Converter-Interfaced Loads , 2012, IEEE Transactions on Smart Grid.

[18]  Li Ke-wu Research on pattern matching method for multivariate time series , 2011 .

[19]  Peter Minns,et al.  Power quality disturbance source identification using self-organising maps , 2010 .

[20]  Richard S. White,et al.  Design, Analysis, and Operation of the Electrical Distribution System for a Modern Electric Arc Furnace and Ladle Melt Furnace , 2010 .

[21]  Walid Morsi,et al.  Fuzzy-Wavelet-Based Electric Power Quality Assessment of Distribution Systems Under Stationary and Nonstationary Disturbances , 2009, IEEE Transactions on Power Delivery.

[22]  Qingshan Jiang,et al.  Pattern Matching Method Based on Point Distribution for Multivariate Time Series: Pattern Matching Method Based on Point Distribution for Multivariate Time Series , 2009 .

[23]  Guan He Pattern Matching Method Based on Point Distribution for Multivariate Time Series , 2009 .

[24]  Dale E. Seborg,et al.  Evaluation of a pattern matching method for the Tennessee Eastman challenge process , 2006 .

[25]  J.V. Milanovic,et al.  Sensitivity of personal computers to voltage sags and short interruptions , 2005, IEEE Transactions on Power Delivery.

[26]  Math Bollen,et al.  Analysis of voltage tolerance of AC adjustable-speed drives for three-phase balanced and unbalanced sags , 1999, 1999 IEEE Industrial and Commercial Power Systems Technical Conference (Cat. No.99CH36371).