Performance assessment of a Solid Desiccant Based on Dehumidifier System Coupled with Air Conditioning System in a Tropical Climate

A comprehensive ventilation approach requires not only air exchange but also in many cases indoor humidity control. High humidity levels decrease occupant comfort and increase the likelihood of problems, such as mold growth. Occupants presently use air-conditioning systems or dehumidifiers in order to reduce the indoor moisture levels. These systems use large amounts of electricity and are expensive. Desiccant systems have shown several advantages, compared to conventional cooling and dehumidification systems. Therefore, their use is also spreading for restaurant and supermarket buildings, especially when the regeneration of the desiccant can be obtained by using available waste heat. When these systems are combined with vapor compression air conditioning systems, air -dry before entering the environment. In this paper Performance assessment of a Solid Desiccant Based on Dehumidifier System Coupled with Air Conditioning in a tropical climate Zone of IRAN have been evaluated. Results indicate that when the hybrid system is used, the efficiency increases 0.76 and energy consumption reduce 3.034kw.

[1]  Edward Allan Vineyard,et al.  Parametric analysis of variables that affect the performance of a desiccant dehumidification system , 2000 .

[2]  Carlo Roselli,et al.  Effect of rotational speed on the performances of a desiccant wheel , 2013 .

[3]  William M. Worek,et al.  Analysis of heat and mass transfer in porous sorbents used in rotary regenerators , 2004 .

[4]  Fatemeh Esfandiari Nia,et al.  Modeling and simulation of desiccant wheel for air conditioning , 2006 .

[5]  Avadhesh Yadav Optimization of Operating Parameters of Desiccant Wheel for Rotation Speed , 2011 .

[6]  Francesco Minichiello,et al.  Desiccant HVAC systems for commercial buildings , 2002 .

[7]  Tianshu Ge,et al.  Technical development of rotary desiccant dehumidification and air conditioning: A review , 2010 .

[8]  Ruzhu Wang,et al.  Use of liquid desiccant cooling to improve the performance of vapor compression air conditioning , 2001 .

[9]  William M. Worek,et al.  NUMERICAL SIMULATION OF COMBINED HEAT AND MASS TRANSFER PROCESSES IN A ROTARY DEHUMIDIFIER , 1993 .

[10]  Wasim Saman,et al.  Comparative study of different desiccant wheel designs , 2011 .

[11]  K. Daou,et al.  Desiccant cooling air conditioning : a review , 2006 .

[12]  Tianshu Ge,et al.  A mathematical model for predicting the performance of a compound desiccant wheel (A model of compound desiccant wheel) , 2010 .

[13]  Rosenberg J. Romero,et al.  Experimental thermodynamic evaluation for a single stage heat transformer prototype build with commercial PHEs , 2015 .

[14]  Ruzhu Wang,et al.  Experimental comparison of two honeycombed desiccant wheels fabricated with silica gel and composite desiccant material , 2006 .

[15]  Stefano De Antonellis,et al.  Simulation, performance analysis and optimization of desiccant wheels , 2010 .

[16]  Wigdan M.H.Kisha,et al.  Experimental Investigation of the performance of a Desiccant Wheel , 2012 .

[17]  Dae-Young Lee,et al.  Optimization of desiccant wheel speed and area ratio of regeneration to dehumidification as a function of regeneration temperature , 2009 .

[18]  S. E. Aly,et al.  Combined absorption-desiccant solar powered air conditioning system , 1988 .