Fast temperature optimization of multi-source hyperthermia applicators with reduced-order modeling of ‘virtual sources’

The goal of this work is to build the foundation for facilitating real-time magnetic resonance image guided patient treatment for heating systems with a large number of physical sources (e.g. antennas). Achieving this goal requires knowledge of how the temperature distribution will be affected by changing each source individually, which requires time expenditure on the order of the square of the number of sources. To reduce computation time, we propose a model reduction approach that combines a smaller number of predefined source configurations (fewer than the number of actual sources) that are most likely to heat tumor. The source configurations consist of magnitude and phase source excitation values for each actual source and may be computed from a CT scan based plan or a simplified generic model of the corresponding patient anatomy. Each pre-calculated source configuration is considered a 'virtual source'. We assume that the actual best source settings can be represented effectively as weighted combinations of the virtual sources. In the context of optimization, each source configuration is treated equivalently to one physical source. This model reduction approach is tested on a patient upper-leg tumor model (with and without temperature-dependent perfusion), heated using a 140 MHz ten-antenna cylindrical mini-annular phased array. Numerical simulations demonstrate that using only a few pre-defined source configurations can achieve temperature distributions that are comparable to those from full optimizations using all physical sources. The method yields close to optimal temperature distributions when using source configurations determined from a simplified model of the tumor, even when tumor position is erroneously assumed to be approximately 2.0 cm away from the actual position as often happens in practical clinical application of pre-treatment planning. The method also appears to be robust under conditions of changing, nonlinear, temperature-dependent perfusion. The proposed approach of using virtual sources reduces the number of variables that must be optimized to achieve a tumor-focused temperature distribution, thereby reducing the calculation time required in real-time control applications to about 1/3 to 1/4 of that required for full optimization.

[1]  H. H. Pennes Analysis of tissue and arterial blood temperatures in the resting human forearm. 1948. , 1948, Journal of applied physiology.

[2]  S K Das,et al.  Computational techniques for fast hyperthermia temperature optimization. , 1999, Medical physics.

[3]  P Wust,et al.  Comparison of MR-thermography and planning calculations in phantoms. , 2006, Medical physics.

[4]  Amir Boag,et al.  Optimal excitation of multiapplicator systems for deep regional hyperthermia , 1988, 1988., IEEE MTT-S International Microwave Symposium Digest.

[5]  R Vanderby,et al.  Temperature-dependent versus constant-rate blood perfusion modelling in ferromagnetic thermoseed hyperthermia: results with a model of the human prostate. , 1994, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[6]  J A de Zwart,et al.  On‐line correction and visualization of motion during MRI‐controlled hyperthermia , 2001, Magnetic resonance in medicine.

[7]  C Gabriel,et al.  The dielectric properties of biological tissues: I. Literature survey. , 1996, Physics in medicine and biology.

[8]  G. Raaphorst,et al.  Changes in muscle blood flow distribution during hyperthermia. , 1997, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[9]  P. Wust,et al.  Methods and potentials of magnetic resonance imaging for monitoring radiofrequency hyperthermia in a hybrid system , 2005, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[10]  H C Charles,et al.  1H MRI phase thermometry in vivo in canine brain, muscle, and tumor tissue. , 1996, Medical physics.

[11]  R. W. Lau,et al.  The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. , 1996, Physics in medicine and biology.

[12]  R Felix,et al.  Evaluation of segmentation algorithms for generation of patient models in radiofrequency hyperthermia , 1998, Physics in medicine and biology.

[13]  K. Hynynen,et al.  MRI guided and monitored focused ultrasound thermal ablation methods: a review of progress , 2004, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[14]  J. Rhee,et al.  Implication of Blood Flow in Hyperthermic Treatment of Tumors , 1984, IEEE Transactions on Biomedical Engineering.

[15]  J A de Zwart,et al.  Local hyperthermia with MR‐guided focused ultrasound: Spiral trajectory of the focal point optimized for temperature uniformity in the target region , 2000, Journal of magnetic resonance imaging : JMRI.

[16]  A. Taflove,et al.  Initial results for automated computational modeling of patient-specific electromagnetic hyperthermia , 1992, IEEE Transactions on Biomedical Engineering.

[17]  Peter Wust,et al.  Thermal monitoring: Invasive, minimal-invasive and non-invasive approaches , 2006, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[18]  Kung-Shan Cheng,et al.  Blood perfusion and thermal conduction effects in Gaussian beam, minimum time single-pulse thermal therapies. , 2005, Medical physics.

[19]  K. M. Sekins,et al.  Local muscle blood flow and temperature responses to 915MHz diathermy as simultaneously measured and numerically predicted. , 1984, Archives of physical medicine and rehabilitation.

[20]  M. Seebass,et al.  Impact of nonlinear heat transfer on temperature control in regional hyperthermia , 1999, IEEE Transactions on Biomedical Engineering.

[21]  Robert Griffin,et al.  Cytotoxicity of perillyl alcohol against cancer cells is potentiated by hyperthermia. , 2003, International journal of radiation oncology, biology, physics.

[22]  P R Stauffer,et al.  Introduction: Thermal ablation therapy , 2004, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[23]  Kullervo Hynynen,et al.  MR monitoring of focused ultrasonic surgery of renal cortex: Experimental and simulation studies , 1995, Journal of magnetic resonance imaging : JMRI.

[24]  Bruce J. Tromberg,et al.  Addition of ionizing radiation or hyperthermia enhances PDT efficacy in glioma spheroids , 2005, SPIE BiOS.

[25]  R. W. Lau,et al.  The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. , 1996, Physics in medicine and biology.