Cardiorespiratory system monitoring using a developed acoustic sensor

This Letter proposes a wireless acoustic sensor for monitoring heartbeat and respiration rate based on phonocardiogram (PCG). The developed sensor comprises a processor, a transceiver which operates at industrial, scientific and medical band and the frequency of 2.54 GHz as well as two capacitor microphones which one for recording the heartbeat and another one for respiration rate. To evaluate the precision of the presented sensor in estimating heartbeat and respiration rate, the sensor is tested on the different volunteers and the obtained results are compared with a gold standard as a reference. The results reveal that root-mean-square error are determined <2.27 beats/min and 0.92 breaths/min for the heartbeat and respiration rate in turn. While the standard deviation of the error is obtained <1.26 and 0.63 for heartbeat and respiration rate, respectively. Also, the sensor estimate sounds of \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{upgreek} \usepackage{mathrsfs} \setlength{\oddsidemargin}{-69pt} \begin{document} }{}$S_1$\end{document}S1 to \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{upgreek} \usepackage{mathrsfs} \setlength{\oddsidemargin}{-69pt} \begin{document} }{}$S_4$\end{document}S4 obtained PCG signal with sensitivity and specificity 98.1% and 98.3% in turn that make 3% improvement than previous works. The results prove that the sensor can be appropriate candidate for recognising abnormal condition in the cardiorespiratory system.

[1]  Maria Romano,et al.  Monitoring of respiration, seismocardiogram and heart sounds by a PVDF piezo film sensor , 2014 .

[2]  Marian Haescher,et al.  A study on measuring heart- and respiration-rate via wrist-worn accelerometer-based seismocardiography (SCG) in comparison to commonly applied technologies , 2015, iWOAR.

[3]  Jianfeng Wang,et al.  Applications, challenges, and prospective in emerging body area networking technologies , 2010, IEEE Wireless Communications.

[4]  Kouhyar Tavakolian,et al.  Ballistocardiography and Seismocardiography: A Review of Recent Advances , 2015, IEEE Journal of Biomedical and Health Informatics.

[5]  Hamidreza Memarzadeh-Tehran,et al.  Technique to estimate human reaction time based on visual perception , 2017, Healthcare technology letters.

[6]  Ahmed Hammouch,et al.  Detection and identification algorithm of the S1 and S2 heart sounds , 2016, 2016 International Conference on Electrical and Information Technologies (ICEIT).

[7]  Nikolaos G. Bourbakis,et al.  A Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis , 2010, IEEE Transactions on Systems, Man, and Cybernetics, Part C (Applications and Reviews).

[8]  Daniel Beckman,et al.  Textile sensor system for electrocardiogram monitoring , 2015, 2015 IEEE Virtual Conference on Applications of Commercial Sensors (VCACS).

[9]  Justin R. Boyle,et al.  Automatic Detection of Respiration Rate From Ambulatory Single-Lead ECG , 2009, IEEE Transactions on Information Technology in Biomedicine.

[10]  A. Nikfarjam,et al.  A mini wearable wireless sensor for rehabilitation applications , 2015, 2015 3rd RSI International Conference on Robotics and Mechatronics (ICROM).

[11]  Uttam M. Chaskar,et al.  FM based eletronic digital stethoscope using DSP , 2014, 2014 International Conference on Control, Instrumentation, Communication and Computational Technologies (ICCICCT).

[12]  R Arathy,et al.  PC based Heart Sound Monitoring System , 2013 .

[13]  Lorenzo Scalise,et al.  Heart Rate assessment by means of a novel approach applied to signals of different nature , 2017 .

[14]  Abbas K. Abbas,et al.  Phonocardiography Signal Processing , 2009, Phonocardiography Signal Processing.

[15]  D. Salerno,et al.  Seismocardiography for monitoring changes in left ventricular function during ischemia. , 1991, Chest.

[16]  Kin Fun Li,et al.  Smart home technology for telemedicine and emergency management , 2012, Journal of Ambient Intelligence and Humanized Computing.

[17]  Reza Abbasi-Kesbi,et al.  A heartbeat and respiration rate sensor based on phonocardiogram for healthcare applications , 2017, 2017 Iranian Conference on Electrical Engineering (ICEE).

[18]  Lionel Tarassenko,et al.  Robust heart rate estimation from noisy phonocardiograms , 2014, Computing in Cardiology 2014.

[19]  J. Habetha,et al.  Detection of S1 and S2 Heart Sounds by High Frequency Signatures , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[20]  H. Naseri,et al.  Detection and Boundary Identification of Phonocardiogram Sounds Using an Expert Frequency-Energy Based Metric , 2012, Annals of Biomedical Engineering.

[21]  G Atkinson,et al.  Statistical Methods For Assessing Measurement Error (Reliability) in Variables Relevant to Sports Medicine , 1998, Sports medicine.

[22]  H. Nazeran,et al.  Digital phonocardiography: a PDA-based approach , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[23]  Hamidreza Memarzadeh-Tehran,et al.  A Patient-Centric Sensory System for In-Home Rehabilitation , 2017, IEEE Sensors Journal.

[24]  Peadar Gilligan,et al.  Telemedicine in pre-hospital care: a review of telemedicine applications in the pre-hospital environment , 2014, International Journal of Emergency Medicine.

[25]  Reza Abbasi-Kesbi,et al.  Denoising MEMS accelerometer sensors based on L2-norm total variation algorithm , 2017 .