Speckle suppression in medical ultrasound images through Schur decomposition

A technique based on Schur decomposition to supress the multiplicative (speckle) noise from medical ultrasound images is presented in this study. An image which carries the speckle noise is divided into small overlapping segments, size of these segments depends on the nature of speckle carried by the image and a global covariance matrix is calculated for the whole image by averaging the covariances of all segments. The global covariance matrix is decomposed through Schur decomposition to obtain the orthogonal vectors. A subset of these orthogonal vectors that correspond to largest magnitudes of eigenvalues are selected to filter out the speckle noise from the image. The proposed approach is compared with four benchmark filtering techniques, homomorphic wavelet despeckling, Wiener, Frost and Gamma. Two types of simulated ultrasound images and five types of real ultrasound images of foetal neck, left kidney, right kidney, musculo skeletal nerve and lymph node are tested. The proposed approach performed maximum suppression of speckle noise in all types of the images with optimal resolution and edge detection. The despeckling performance of the proposed approach is even better compared with the benchmark schemes once the speckle noise is rough, which is usually the case for soft tissue.

[1]  J. Goodman Some fundamental properties of speckle , 1976 .

[2]  Kaifu Wang,et al.  A switching median–mean filter for removal of high-density impulse noise from digital images , 2015 .

[3]  J. Jensen,et al.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  K. Boone,et al.  Effect of skin impedance on image quality and variability in electrical impedance tomography: a model study , 1996, Medical and Biological Engineering and Computing.

[5]  A. Tannenbaum,et al.  Despeckling of medical ultrasound images , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  Xiaorong Gao,et al.  Multi-Scale Nonlinear Thresholding for Ultrasonic Speckle Suppression , 1999, IEEE Trans. Medical Imaging.

[7]  Gail ter Haar,et al.  Thermal ablation of uterine fibroids using MR-guided focused ultrasound-a truly non-invasive treatment modality , 2007, European Radiology.

[8]  Nupur Saxena,et al.  A Review on Speckle Noise Filtering Techniques for SAR Images , 2013 .

[9]  H. M. Salinas,et al.  Comparison of PDE-Based Nonlinear Diffusion Approaches for Image Enhancement and Denoising in Optical Coherence Tomography , 2007, IEEE Transactions on Medical Imaging.

[10]  João Manuel R. S. Tavares,et al.  Smoothing of ultrasound images using a new selective average filter , 2016, Expert Syst. Appl..

[11]  Victor S. Frost,et al.  A Model for Radar Images and Its Application to Adaptive Digital Filtering of Multiplicative Noise , 1982, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[12]  S C Saxena,et al.  Homomorphic wavelet thresholding technique for denoising medical ultrasound images , 2005, Journal of medical engineering & technology.

[13]  D. Downey,et al.  Three-dimensional ultrasound imaging , 1995, Medical Imaging.

[14]  Alin Achim,et al.  Novel Bayesian multiscale method for speckle removal in medical ultrasound images , 2001, IEEE Transactions on Medical Imaging.

[16]  William K. Pratt,et al.  Generalized Wiener Filtering Computation Techniques , 1972, IEEE Transactions on Computers.