Analytical characterization of RF phase‐cycled balanced steady‐state free precession

Balanced steady-state free precession (bSSFP) techniques, commonly called True-FISP, FIESTA, or balanced FFE, are rapid, efficient, high signal-to-noise ratio sequences used in angiographic, cardiac and abdominal MR imaging. One of their major drawbacks is their sensitivity to off-resonance effects arising from Bo inhomogeneities, which can produce the familiar dark bands in the images. Radio frequency (RF) phase cycling is known to minimize this artifact. Although RF phase-cycled bSSFP is an accepted and firmly established technique, a simple and intuitive analytical signal equation has not yet been provided. Here, a complete theoretical framework is developed from which insightful characterizations such as signal uniformity, optimal flip angle, SNR efficiency, and banding effect minimization are provided. The analytical predictions and guidelines are substantiated via direct numerical simulations for clinically relevant tissues (e.g., water-like organs and lipids) using various acquisition conditions, and also verified experimentally with phantoms. We demonstrate that the banding artifact can be virtually eliminated, even for phantoms immersed in significantly nonuniform magnetic fields. © 2009 Wiley Periodicals, Inc. Concepts Magn Reson Part A 34A: 133–143, 2009.

[1]  W. Edelstein,et al.  The intrinsic signal‐to‐noise ratio in NMR imaging , 1986, Magnetic resonance in medicine.

[2]  M. L. Wood,et al.  Motion‐insensitive, steady‐state free precession imaging , 1990, Magnetic resonance in medicine.

[3]  J S Lewin,et al.  Fast T2‐weighted imaging by PSIF at 0.2 T for interventional MRI , 1999, Magnetic resonance in medicine.

[4]  K. Scheffler,et al.  Principles and applications of balanced SSFP techniques , 2003, European Radiology.

[5]  P. Choyke,et al.  MR angiography using steady‐state free precession , 2002, Magnetic resonance in medicine.

[6]  J. Debatin,et al.  MRI of the liver: Can true FISP replace HASTE? , 2003, Journal of magnetic resonance imaging : JMRI.

[7]  Petra Schmalbrock,et al.  A segment‐interleaved motion‐compensated acquisition in the steady state (SIMCAST) technique for high resolution imaging of the inner ear , 1997, Journal of magnetic resonance imaging : JMRI.

[8]  K. Scheffler,et al.  Single‐breathhold 3D‐trueFISP cine cardiac imaging , 2002, Magnetic resonance in medicine.

[9]  E M Haacke,et al.  Steady-state free precession imaging in the presence of motion: application for improved visualization of the cerebrospinal fluid. , 1990, Radiology.

[10]  W. Hinshaw,et al.  Image formation by nuclear magnetic resonance: The sensitive‐point method , 1976 .

[11]  Dwight G Nishimura,et al.  Analysis of multiple‐acquisition SSFP , 2004, Magnetic resonance in medicine.

[12]  Dual-acquisition phase-sensitive fat-water separation using balanced steady-state free precession. , 2006, Magnetic resonance imaging.

[13]  Orlando P Simonetti,et al.  Cardiac function: MR evaluation in one breath hold with real-time true fast imaging with steady-state precession. , 2002, Radiology.