Disaggregation process for dynamic multidimensional heat flux in building simulation

Heat transfer across envelopes (facade, roof, glazed areas) represents a big share of the energy flow within the heat balance of buildings. This paper focuses on areas of the envelope where multi-dimensional heat transfer occurs. These areas are commonly defined as thermal bridges, due to a localized reduction of thermal resistance of constructions in these places. This paper reviews common standardized methods to assess heat transfer in buildings, under various modelling assumptions: one-dimensional, multi-dimensional, steady state and dynamic. Within presently developed modelling and assessment methods, a need for improvement has been identified over existing methods for the thermal assessment of multi-dimensional heat transfer under dynamic conditions. A phasorial approach to differential heat transfer in thermal bridges has been developed, which serves as the dynamic extension of steady-state thermal bridge coefficients. This formulation is applied to the junction of a masonry wall with a concrete slab.

[1]  A. Ben Larbi Statistical modelling of heat transfer for thermal bridges of buildings , 2005 .

[2]  D. G. Stephenson,et al.  Room thermal response factors , 1967 .

[3]  Daniel R. Rousse,et al.  Experimental and numerical characterization of thermal bridges in prefabricated building walls , 2010 .

[4]  I. Simões,et al.  Simulation of dynamic linear thermal bridges using a boundary element method model in the frequency , 2011 .

[5]  Paul Strachan,et al.  IEA Annex 58: Full-scale Empirical Validation of Detailed Thermal Simulation Programs , 2015 .

[6]  Jan Kosny,et al.  Two-Step Procedure for Determining Three-Dimensional Conduction Z-Transfer Function Coefficients for Complex Building Envelope Assemblies , 2004 .

[7]  Luis Pérez-Lombard,et al.  A review on buildings energy consumption information , 2008 .

[8]  Björn Berggren,et al.  Calculation of thermal bridges in (Nordic) building envelopes - Risk of performance failure due to inconsistent use of methodology , 2013 .

[9]  Joseph Andrew Clarke,et al.  Energy Simulation in Building Design , 1985 .

[10]  Theodoros Theodosiou,et al.  The impact of thermal bridges on the energy demand of buildings with double brick wall constructions , 2008 .

[11]  José María Sala,et al.  Methodology for the calculation of response factors through experimental tests and validation with simulation , 2010 .

[12]  Hua Ge,et al.  Impact of balcony thermal bridges on the overall thermal performance of multi-unit residential buildings: A case study , 2013 .

[13]  S. A. Al-Sanea,et al.  Finite-volume thermal analysis of building roofs under two-dimensional periodic conditions , 2003 .

[14]  Kevan A. C. Martin,et al.  Problems in the calculation of thermal bridges in dynamic conditions , 2011 .

[15]  Natale Arcuri,et al.  Dynamic Thermal Characteristics of Opaque Building Components. A Proposal for the Extension of EN ISO 13786 , 2015 .

[16]  Laurent Mora,et al.  Comparison of different methods for calculating thermal bridges: Application to wood-frame buildings , 2015 .

[17]  Jan Kosny,et al.  Three-dimensional conduction z-transfer function coefficients determined from the response factors , 2005 .