Chest Tomosynthesis: Technical and Clinical Perspectives

The recent implementation of chest tomosynthesis is built on the availability of large, dose-efficient, high-resolution flat panel detectors, which enable the acquisition of the necessary number of projection radiographs to allow reconstruction of section images of the chest within one breath hold. A chest tomosynthesis examination obtains the increased diagnostic information provided by volumetric imaging at a radiation dose comparable to that of conventional chest radiography. There is evidence that the sensitivity of chest tomosynthesis may be at least three times higher than for conventional chest radiography for detection of pulmonary nodules. The sensitivity increases with increasing nodule size and attenuation and decreases for nodules with subpleural location. Differentiation between pleural and subpleural lesions is a known pitfall due to the limited depth resolution in chest tomosynthesis. Studies on different types of pathology report increased detectability in favor of chest tomosynthesis in comparison to chest radiography. The technique provides improved diagnostic accuracy and confidence in the diagnosis of suspected pulmonary lesions on chest radiography and facilitates the exclusion of pulmonary lesions in a majority of patients, avoiding the need for computed tomography (CT). However, motion artifacts can be a cumbersome limitation and breathing during the tomosynthesis image acquisition may result in severe artifacts significantly affecting the detectability of pathology. In summary, chest tomosynthesis has been shown to be superior to chest conventional radiography for many tasks and to be able to replace CT in selected cases. In our experience chest tomosynthesis is an efficient problem solver in daily clinical work.

[1]  James T Dobbins,et al.  The effect of averaging adjacent planes for artifact reduction in matrix inversion tomosynthesis. , 2013, Medical physics.

[2]  Santiago Martinez-Jimenez,et al.  Digital tomosynthesis of the chest for lung nodule detection: interim sensitivity results from an ongoing NIH-sponsored trial. , 2008, Medical physics.

[3]  Joseph Y. Lo,et al.  Gaussian frequency blending algorithm with matrix inversion tomosynthesis (MITS) and filtered back projection (FBP) for better digital breast tomosynthesis reconstruction , 2006, SPIE Medical Imaging.

[4]  Haruhiko Machida,et al.  Optimizing parameters for flat-panel detector digital tomosynthesis. , 2010, Radiographics : a review publication of the Radiological Society of North America, Inc.

[5]  Antoine Flahault,et al.  Baseline results of the Depiscan study: a French randomized pilot trial of lung cancer screening comparing low dose CT scan (LDCT) and chest X-ray (CXR). , 2007, Lung cancer.

[6]  D. Godfrey,et al.  Optimization of the matrix inversion tomosynthesis (MITS) impulse response and modulation transfer function characteristics for chest imaging. , 2006, Medical physics.

[7]  Andrea Viti,et al.  Lung Cancer Detection with Digital Chest Tomosynthesis: Baseline Results from the Observational Study SOS , 2013, Journal of thoracic oncology : official publication of the International Association for the Study of Lung Cancer.

[8]  M Båth,et al.  Effect of clinical experience of chest tomosynthesis on detection of pulmonary nodules , 2009, Acta radiologica.

[9]  Magnus Båth,et al.  Nodule detection in digital chest radiography: part of image background acting as pure noise. , 2005, Radiation protection dosimetry.

[10]  J. Geitung,et al.  Clinical utility of chest roentgenograms , 1999, European Radiology.

[11]  M Båth,et al.  Overview of two years of clinical experience of chest tomosynthesis at Sahlgrenska University Hospital. , 2010, Radiation protection dosimetry.

[12]  M. Maher,et al.  Radiologic imaging in cystic fibrosis: cumulative effective dose and changing trends over 2 decades. , 2012, Chest.

[13]  Jonas Ivarsson,et al.  Learning aspects and potential pitfalls regarding detection of pulmonary nodules in chest tomosynthesis and proposed related quality criteria , 2011, Acta radiologica.

[14]  David Rodman,et al.  Cystic fibrosis adult care: consensus conference report. , 2004, Chest.

[15]  Anders Tingberg,et al.  Nodule detection in digital chest radiography: summary of the RADIUS chest trial. , 2005, Radiation protection dosimetry.

[16]  Hiroaki Sugiura,et al.  Fast Scanning Tomosynthesis for the Detection of Pulmonary Nodules: Diagnostic Performance Compared With Chest Radiography, Using Multidetector-Row Computed Tomography as the Reference , 2011, Investigative radiology.

[17]  Emilio Quaia,et al.  Digital tomosynthesis as a problem-solving imaging technique to confirm or exclude potential thoracic lesions based on chest X-ray radiography. , 2013, Academic radiology.

[18]  H. C. Kim,et al.  Digital tomosynthesis of the chest: utility for detection of lung metastasis in patients with colorectal cancer. , 2012, Clinical radiology.

[19]  Magnus Båth,et al.  Nodule detection in digital chest radiography: effect of nodule location. , 2005, Radiation protection dosimetry.

[20]  P. Ehrlich,et al.  Should helical CT scanning of the thoracic cavity replace the conventional chest x-ray as a primary assessment tool in pediatric trauma? An efficacy and cost analysis. , 2003, Journal of pediatric surgery.

[21]  G. Enríquez,et al.  Low-dose high-resolution CT of the chest in children and young adults: dose, cooperation, artifact incidence, and image quality. , 2000, AJR. American journal of roentgenology.

[22]  Magnus Båth,et al.  Monte Carlo simulations of the dosimetry of chest tomosynthesis. , 2010, Radiation protection dosimetry.

[23]  James T. Dobbins,et al.  Chest tomosynthesis: technical principles and clinical update. , 2009, European journal of radiology.

[24]  James T. Dobbins,et al.  Digital tomosynthesis of the chest. , 2008, Journal of thoracic imaging.

[25]  L. Greco,et al.  Cystic fibrosis: when should high-resolution computed tomography of the chest Be obtained? , 1998, Pediatrics.

[26]  Kyung Soo Lee,et al.  Digital tomosynthesis of the thorax: the influence of respiratory motion artifacts on lung nodule detection , 2013, Acta radiologica.

[27]  Anders Tingberg,et al.  X-ray tomosynthesis: a review of its use for breast and chest imaging. , 2010, Radiation protection dosimetry.

[28]  K I Kim,et al.  Comparison of chest digital tomosynthesis and chest radiography for detection of asbestos-related pleuropulmonary disease. , 2013, Clinical radiology.

[29]  A. Flinck,et al.  Comparison of chest tomosynthesis and chest radiography for detection of pulmonary nodules: human observer study of clinical cases. , 2008, Radiology.

[30]  Kyung Soo Lee,et al.  Pulmonary mycobacterial disease: diagnostic performance of low-dose digital tomosynthesis as compared with chest radiography. , 2010, Radiology.

[31]  Emilio Quaia,et al.  The value of digital tomosynthesis in the diagnosis of suspected pulmonary lesions on chest radiography: analysis of diagnostic accuracy and confidence. , 2010, Academic radiology.

[32]  J. Dobbins Tomosynthesis imaging: at a translational crossroads. , 2009, Medical physics.

[33]  Jonas Ivarsson,et al.  Rediscovering radiology: New technologies and remedial action at the worksite , 2011, Social studies of science.

[34]  A. Stromberg,et al.  Surveillance after surgical treatment of melanoma: futility of routine chest radiography. , 2010, Surgery.

[35]  Magnus Båth,et al.  Effective dose to patients from chest examinations with tomosynthesis. , 2010, Radiation protection dosimetry.

[36]  Magnus Båth,et al.  Pulmonary nodule size evaluation with chest tomosynthesis. , 2012, Radiology.

[37]  Kenji Ogawa,et al.  Tomosynthesis for the early detection of pulmonary emphysema: diagnostic performance compared with chest radiography, using multidetector computed tomography as reference , 2013, European Radiology.

[38]  J. Payne CT radiation dose and image quality. , 2005, Radiologic clinics of North America.

[39]  W. Huda,et al.  Effective doses in radiology and diagnostic nuclear medicine: a catalog. , 2008, Radiology.

[40]  M Båth,et al.  A phantom study of nodule size evaluation with chest tomosynthesis and computed tomography. , 2010, Radiation protection dosimetry.

[41]  D. Naidich,et al.  Overview and Strategic Management of Subsolid Pulmonary Nodules , 2012, Journal of thoracic imaging.

[42]  John M. Sabol,et al.  A Monte Carlo estimation of effective dose in chest tomosynthesis. , 2009, Medical physics.

[43]  T. Robinson Imaging of the chest in cystic fibrosis. , 2007, Clinics in chest medicine.

[44]  Arno W Hoes,et al.  Chest radiography in general practice: indications, diagnostic yield and consequences for patient management. , 2006, The British journal of general practice : the journal of the Royal College of General Practitioners.

[45]  O. M. Arıyürek,et al.  High resolution CT in children with cystic fibrosis: correlation with pulmonary functions and radiographic scores. , 2001, European journal of radiology.

[46]  C. Schaefer-Prokop,et al.  Pulmonary infections in the late period after allogeneic bone marrow transplantation: chest radiography versus computed tomography. , 2005, European journal of radiology.

[47]  C. McCollough,et al.  CT dose reduction and dose management tools: overview of available options. , 2006, Radiographics : a review publication of the Radiological Society of North America, Inc.

[48]  E Samei,et al.  Detection of subtle lung nodules: relative influence of quantum and anatomic noise on chest radiographs. , 1999, Radiology.

[49]  J. Rakowski,et al.  A comparison of reconstruction algorithms for C-arm mammography tomosynthesis. , 2006, Medical physics.

[50]  H. Zonderland,et al.  Limited value of chest radiography in predicting aetiology of lower respiratory tract infection in general practice. , 2008, The British journal of general practice : the journal of the Royal College of General Practitioners.

[51]  Lubomir M. Hadjiiski,et al.  A comparative study of limited-angle cone-beam reconstruction methods for breast tomosynthesis. , 2006, Medical physics.

[52]  L. Kuhns,et al.  Use of computerized tomography and chest X‐rays in evaluating efficacy of aerosolized recombinant human DNase in cystic fibrosis patients younger than age 5 years: A preliminary study * , 2001, Pediatric pulmonology.

[53]  M. Chung,et al.  Digital Tomosynthesis of the Chest: Comparison of Patient Exposure Dose and Image Quality between Standard Default Setting and Low Dose Setting , 2013, Korean journal of radiology.

[54]  Masaki Katsura,et al.  Model-Based Iterative Reconstruction Technique for Ultralow-Dose Chest CT: Comparison of Pulmonary Nodule Detectability With the Adaptive Statistical Iterative Reconstruction Technique , 2013, Investigative radiology.

[55]  H. Ohmatsu,et al.  Peripheral lung cancer: screening and detection with low-dose spiral CT versus radiography. , 1996, Radiology.

[56]  N. Gürmen,et al.  Lung parenchymal injury and its frequency in blunt thoracic trauma: the diagnostic value of chest radiography and thoracic CT. , 2007, Diagnostic and interventional radiology.

[57]  Filippo Cademartiri,et al.  Predictive value of chest CT in patients with cystic fibrosis: a single-center 10-year experience. , 2008, AJR. American journal of roentgenology.

[58]  Mats Geijer,et al.  Tomosynthesis in pulmonary cystic fibrosis with comparison to radiography and computed tomography: a pictorial review , 2011, Insights into Imaging.

[59]  Anders Tingberg,et al.  Nodule detection in digital chest radiography: introduction to the RADIUS chest trial. , 2005, Radiation protection dosimetry.

[60]  遠藤 幸男,et al.  Digital Tomosynthesis における臨床応用への課題 , 1994 .

[61]  David Price,et al.  Earlier diagnosis and earlier treatment of COPD in primary care. , 2010, Primary care respiratory journal : journal of the General Practice Airways Group.

[62]  J. Mayo,et al.  Radiation exposure at chest CT: a statement of the Fleischner Society. , 2003, Radiology.

[63]  Magnus Båth,et al.  Simulation of dose reduction in tomosynthesis. , 2009, Medical physics.

[64]  James T Dobbins,et al.  Digital x-ray tomosynthesis: current state of the art and clinical potential. , 2003, Physics in medicine and biology.

[65]  Christoph Hoeschen,et al.  Nodule detection in digital chest radiography: effect of anatomical noise. , 2005, Radiation protection dosimetry.

[66]  Emilio Quaia,et al.  Analysis of the impact of digital tomosynthesis on the radiological investigation of patients with suspected pulmonary lesions on chest radiography , 2012, European Radiology.

[67]  B. van Ginneken,et al.  Pulmonary perifissural nodules on CT scans: rapid growth is not a predictor of malignancy. , 2012, Radiology.

[68]  Jonas Ivarsson,et al.  Application of a computed tomography based cystic fibrosis scoring system to chest tomosynthesis , 2013, Medical Imaging.

[69]  Magnus Båth,et al.  Nodule detection in digital chest radiography: effect of system noise. , 2005, Radiation protection dosimetry.

[70]  Tao Wu,et al.  A comparison of reconstruction algorithms for breast tomosynthesis. , 2004, Medical physics.

[71]  Devon J Godfrey,et al.  Stochastic noise characteristics in matrix inversion tomosynthesis (MITS). , 2009, Medical physics.