A prospective, multicenter trial of the VentrAssist left ventricular assist device for bridge to transplant: safety and efficacy.

BACKGROUND The increasing prevalence of chronic heart failure has stimulated the ongoing development of left ventricular assist devices (LVADs) for both bridge-to-transplant (BTT) and destination therapy (DT). The aim of this prospective, multicenter clinical trial was to determine the efficacy and safety of a third-generation LVAD, the VentrAssist, in a BTT cohort. METHODS Patients (n = 33) with end-stage chronic heart failure who required circulatory support as BTT therapy were implanted with a VentrAssist device. The primary outcome was survival until transplant or transplant eligibility with the device in situ at trial end-point (Day 154 after implant). The secondary outcomes were pump flow index and end-organ function. Safety, patient functional status and resource use were also assessed. RESULTS At trial end-point, the success rate was 82% (39.4% transplanted, 42.4% transplant-eligible). The LVAD pump flow index (median >or=2.7 liters/min/m(2)) was sufficient to maintain an adequate circulation and significantly improve end-organ function. Of the 77 protocol-defined serious adverse events, most occurred within 30 days of implantation. No patients died as a direct result of pump failure or malfunction. After implantation, patient functional status improved, with 70% of patients achieving hospital discharge, and resource use was reduced. CONCLUSIONS This trial demonstrated a favorable efficacy and safety profile for use of the VentrAssist LVAD in BTT patients.

[1]  L. Miller,et al.  Candidate selection for long-term left ventricular assist device therapy for refractory heart failure. , 2006, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[2]  L. Sharples,et al.  Evaluation of the clinical effectiveness of the Ventricular Assist Device Program in the United Kingdom (EVAD UK). , 2007, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[3]  J. Kirklin,et al.  Mechanical circulatory support therapy as a bridge to transplant or recovery (new advances) , 2006, Current opinion in cardiology.

[4]  R. Kormos,et al.  Mechanical circulatory support device database of the International Society for Heart and Lung Transplantation: third annual report--2005. , 2005, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[5]  David Kaye,et al.  First clinical implant of the VentrAssist left ventricular assist system as destination therapy for end-stage heart failure. , 2005, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[6]  S. Yusuf,et al.  A lifetime of prevention: the case of heart failure. , 2002, Circulation.

[7]  Christoph Schmidt,et al.  Long-term support of 9 patients with the DeBakey VAD for more than 200 days. , 2005, The Journal of thoracic and cardiovascular surgery.

[8]  R. Kormos,et al.  Mechanical Circulatory Support Device Database of the International Society for Heart and Lung Transplantation: Third Annual Report—2005⁎ ⁎All figures and tables from this report, and a more comprehensive set of ISHLT registry slides are available at www.ishlt.org/registries/ , 2005 .

[9]  O H Frazier,et al.  Use of a continuous-flow device in patients awaiting heart transplantation. , 2007, The New England journal of medicine.

[10]  F. Oliva,et al.  Bridge to transplantation with the MicroMed DeBakey ventricular assist device axial pump: a single centre report , 2006, Journal of cardiovascular medicine.

[11]  John Woodard,et al.  VentrAssist left ventricular assist device: clinical trial results and Clinical Development Plan update. , 2007, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[12]  P. Royle,et al.  Clinical effectiveness and cost-effectiveness of immediate angioplasty for acute myocardial infarction: systematic review and economic evaluation. , 2005, Health technology assessment.

[13]  Andrew J. Martin,et al.  A cardiovascular extension of the Health Measurement Questionnaire. , 1999, Journal of epidemiology and community health.

[14]  Roland Hetzer,et al.  Does total implantability reduce infection with the use of a left ventricular assist device? The LionHeart experience in Europe. , 2007, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[15]  P. Royle,et al.  The clinical and cost-effectiveness of left ventricular assist devices for end-stage heart failure: a systematic review and economic evaluation. , 2005, Health technology assessment.

[16]  M. Redfield,et al.  Heart failure--an epidemic of uncertain proportions. , 2002, The New England journal of medicine.

[17]  Heinrich Schima,et al.  The DuraHeart VAD, a magnetically levitated centrifugal pump: the University of Vienna bridge-to-transplant experience. , 2006, Circulation journal : official journal of the Japanese Circulation Society.

[18]  Robert L. Kormos,et al.  Mechanical Circulatory Support device database of the International Society for Heart and Lung Transplantation: first annual report--2003. , 2003, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[19]  M C Oz,et al.  Long-term use of a left ventricular assist device for end-stage heart failure. , 2001, The New England journal of medicine.

[20]  O. Frazier,et al.  Is bridging to transplantation with a left ventricular assist device a risk factor for transplant coronary artery disease? , 2005, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[21]  D. Goldstein,et al.  Worldwide Experience With the MicroMed DeBakey Ventricular Assist Device® as a Bridge to Transplantation , 2003, Circulation.

[22]  C. Gudex,et al.  The QALY toolkit , 1988 .

[23]  K C Cain,et al.  Charts for the early stopping of pilot studies. , 1984, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.