Detection of respiratory tumour motion using intrinsic list mode-driven gating in positron emission tomography

PurposeRespiratory motion of organs during PET scans is known to degrade PET image quality, potentially resulting in blurred images, attenuation artefacts and erroneous tracer quantification. List mode-based gating has been shown to reduce these pitfalls in cardiac PET. This study evaluates these intrinsic gating methods for tumour PET scans.MethodsA total of 34 patients with liver or lung tumours (14 liver tumours and 27 lung tumours in all) underwent a 15-min single-bed list mode PET scan of the tumour region. Of these, 15 patients (8 liver and 11 lung tumours in total) were monitored by a video camera registering a marker on the patient’s abdomen, thus capturing the respiratory motion for PET gating (video method). Further gating information was deduced by dividing the list mode stream into 200-ms frames, determining the number of coincidences (sensitivity method) and computing the axial centre of mass of the measured count rates in the same frames (centre of mass method). Additionally, these list mode-based methods were evaluated using only coincidences originating from the tumour region by segmenting the tumour in sinogram space (segmented sensitivity/centre of mass method). Measured displacement of the tumours between end-expiration and end-inspiration and the increase in apparent uptake in the gated images served as a measure for the exactness of gating. To estimate the accuracy, a thorax phantom study with moved activity sources simulating small tumours was also performed.ResultsAll methods resolved the respiratory motion with varying success. The best results were seen in the segmented centre of mass method, on average leading to larger displacements and uptake values than the other methods. The simple centre of mass method performed worse in terms of displacements due to activities moving into the field of view during the respiratory cycle. Both sensitivity- and video-based methods lead to similar results.ConclusionList mode-driven PET gating, especially the segmented centre of mass method, is feasible and accurate in PET scans of liver and lung tumours.

[1]  George T. Y. Chen,et al.  Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion. , 2005, International journal of radiation oncology, biology, physics.

[2]  O. Schober,et al.  Respiratory gating in positron emission tomography: a quantitative comparison of different gating schemes. , 2007, Medical physics.

[3]  Jianfeng He,et al.  Evaluation of Geometrical Sensitivity for Respiratory Motion Gating by GATE and NCAT Simulation , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[4]  C. Ling,et al.  Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancer. , 2002, Medical physics.

[5]  K. Lam,et al.  Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing. , 1996, International journal of radiation oncology, biology, physics.

[6]  M.H. Ho,et al.  Real-time system for respiratory-cardiac gating in positron tomography , 1997, 1997 IEEE Nuclear Science Symposium Conference Record.

[7]  Paul Kinahan,et al.  A combined PET/CT scanner for clinical oncology. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[8]  Matthias Guckenberger,et al.  Is a single respiratory correlated 4D-CT study sufficient for evaluation of breathing motion? , 2007, International journal of radiation oncology, biology, physics.

[9]  James M Balter,et al.  Evaluation of the influence of breathing on the movement and modeling of lung tumors. , 2002, International journal of radiation oncology, biology, physics.

[10]  P. Keall 4-dimensional computed tomography imaging and treatment planning. , 2004, Seminars in radiation oncology.

[11]  S. Nekolla,et al.  Postacquisition Detection of Tumor Motion in the Lung and Upper Abdomen Using List-Mode PET Data: A Feasibility Study , 2007, Journal of Nuclear Medicine.

[12]  Jose Belderbos,et al.  Acute esophageal toxicity in non-small cell lung cancer patients after high dose conformal radiotherapy. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[13]  C. Koch,et al.  In regard to Vordermark et al. (Int J Radiat Oncol Biol Phys 2004;58:1242-1250). , 2004, International journal of radiation oncology, biology, physics.

[14]  Timothy D. Solberg,et al.  Phase versus amplitude sorting of 4D‐CT data , 2006, Journal of applied clinical medical physics.

[15]  Paul Kinahan,et al.  Attenuation correction for a combined 3D PET/CT scanner. , 1998, Medical physics.

[16]  M. Daube-Witherspoon,et al.  Treatment of axial data in three-dimensional PET. , 1987, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[17]  C. Ling,et al.  Effect of respiratory gating on quantifying PET images of lung cancer. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[18]  Andrea Lupi,et al.  The effect of 18F-FDG-PET/CT respiratory gating on detected metabolic activity in lung lesions , 2009, Annals of nuclear medicine.

[19]  George Starkschall,et al.  Evaluation of internal lung motion for respiratory-gated radiotherapy using MRI: Part I--correlating internal lung motion with skin fiducial motion. , 2004, International journal of radiation oncology, biology, physics.

[20]  P. Marsden,et al.  Retrospective data-driven respiratory gating for PET/CT , 2008, Physics in medicine and biology.

[21]  O. Schober,et al.  List Mode–Driven Cardiac and Respiratory Gating in PET , 2009, Journal of Nuclear Medicine.

[22]  Florian Büther,et al.  Organ movement reduction in PET/CT using dual-gated list-mode acquisition. , 2006, Zeitschrift fur medizinische Physik.