Effect of Hooked-End Steel Fibres Geometry on Pull-Out Behaviour of Ultra-High Performance Concrete

In this study, a comprehensive approach has been adopted to examine in detail the effect of various hook geometries on bond-slip characteristics. Extensive single fibre pull-out tests on ultra-high performance matrix with three different W/B ratios and embedded lengths have been carried out. Test results showed that the mechanical deformation of fibre hook is the main mechanism governing the pull-out behaviour. Furthermore, the quantitative analyses have been completed to compare the hook design contribution of 3D, 4D and 5D fibres to assess overall pull-out behaviour. It was also revealed that there is a strong relationship between the magnitude of hook contribution and W/B ratio (i.e. matrix strength). Reducing the W/B ratio from 0.20 to 0.11 greatly optimizes the interfacial transition zone (ITZ) and enables better mobilization, straightening of the hook and results in bond-sliphardening behaviour. Keywords—bond mechanisms, fibre-matrix interface, hook geometry, pullout behaviour and water to binder ratio.

[1]  Halit Yazici,et al.  Pull-out behavior of steel fiber embedded in flowable RPC and ordinary mortar , 2015 .

[2]  M. Fan,et al.  Anchorage Effects of Various Steel Fibre Architectures for Concrete Reinforcement , 2016 .

[3]  Antoine E. Naaman,et al.  Engineered Steel Fibers with Optimal Properties for Reinforcement of Cement Composites , 2003 .

[4]  Antoine E. Naaman,et al.  Bond-Slip Mechanisms of Steel Fibers in Concrete , 1991 .

[5]  A. Naaman,et al.  Pullout Behavior of High-Strength Steel Fibers Embedded in Ultra-High-Performance Concrete , 2012 .

[6]  Behnam Kiani,et al.  Application of different fibers to reduce plastic shrinkage cracking of concrete , 2012 .

[7]  Gilles Chanvillard,et al.  Modeling the pullout of wire-drawn steel fibers ? ? This paper was originally submitted to Advanced , 1999 .

[8]  Eray Baran,et al.  Pull-out behavior of prestressing strands in steel fiber reinforced concrete , 2012 .

[9]  Antoine E. Naaman,et al.  Bond Stress Model for Fiber Reinforced Concrete Based on Bond Stress-Slip Relationship , 1989 .

[10]  Nemkumar Banthia,et al.  A study of some factors affecting the fiber–matrix bond in steel fiber reinforced concrete , 1990 .

[11]  E. Zīle,et al.  Effect of the fiber geometry on the pullout response of mechanically deformed steel fibers , 2013 .

[12]  Luc Taerwe,et al.  A semi-analytical model to predict the pull-out behaviour of inclined hooked-end steel fibres , 2013 .

[13]  Pierre-Claude Aitcin,et al.  Pull-out behavior of corrugated steel fibers: Qualitative and statistical analysis , 1996 .

[14]  Mizi Fan,et al.  Analysis and modelling of mechanical anchorage of 4D/5D hooked end steel fibres , 2016 .

[15]  I. Marković,et al.  High-Performance Hybrid-Fibre Concrete: Development and Utilisation , 2006 .

[16]  Filipe Laranjeira de Oliveira Design-oriented constitutive model for steel fiber reinforced concrete , 2010 .

[17]  Taher Abu-Lebdeh,et al.  Effect of matrix strength on pullout behavior of steel fiber reinforced very-high strength concrete composites , 2011 .

[18]  Jin-Keun Kim,et al.  Pullout behavior of inclined steel fiber in an ultra-high strength cementitious matrix , 2010 .

[19]  Vitor M. C. F. Cunha,et al.  Steel fibre reinforced self-compacting concrete (from micromechanics to composite behavior) , 2010 .

[20]  Antoine E. Naaman,et al.  Effect of mechanical clamping on the pull-out response of hooked steel fibers embedded in cementitious matrices , 2022 .

[21]  Dong Joo Kim,et al.  Strain rate effect on high performance fiber reinforced cementitious composites using slip hardening high strength deformed steel fibers , 2009 .

[22]  Nemkumar Banthia,et al.  Concrete Reinforced with Deformed Steel Fibers, Part I: Bond-Slip Mechanisms , 1994 .

[23]  M. Shekarchi,et al.  Statistical and experimental analysis on the behavior of fiber reinforced concretes subjected to drop weight test , 2012 .