Economic Evaluation of ESS in Urban Railway Substation for Peak Load Shaving Based on Net Present Value

In this paper, we estimate the economic benefits of Energy Storage Systems (ESSs) for peak load shaving in an urban railway substation using the annual cost. The annual investment cost of ESSs is estimated using Net Present Value (NPV) and compared with the cost reduction of electricity by the ESS. The optimal capacities of the battery and Power Converting System (PCS) are determined for peak load shaving. The optimal capacity of the ESS and the peak load shaving is determined to maximize the profit by the ESS. The proposed method was applied to real load data in an urban railway substation, and the results show that electric power costs can be reduced. Other aspects of the ESS, such as the lifetime and unit price of the battery, are also investigated economically.

[1]  Shuaixun Chen,et al.  Sizing of energy storage for microgrids , 2012, 2012 IEEE Power and Energy Society General Meeting.

[2]  A·佩斯,et al.  Method for operating energy storage system , 2009 .

[3]  Hyungchul Kim,et al.  Capacity Determination of ESS for Peak Load Shaving Based on the Actual Measurement of Loads in the Substation of Urban Railway , 2014 .

[4]  A. Oudalov,et al.  Sizing and Optimal Operation of Battery Energy Storage System for Peak Shaving Application , 2007, 2007 IEEE Lausanne Power Tech.

[5]  Y. M. Atwa,et al.  Optimal Allocation of ESS in Distribution Systems With a High Penetration of Wind Energy , 2010, IEEE Transactions on Power Systems.

[6]  H. Bludszuweit,et al.  A Probabilistic Method for Energy Storage Sizing Based on Wind Power Forecast Uncertainty , 2011, IEEE Transactions on Power Systems.

[7]  Seddik Bacha,et al.  Battery Storage System sizing in distribution feeders with distributed photovoltaic systems , 2009, 2009 IEEE Bucharest PowerTech.

[8]  Magnus Korpaas,et al.  Operation and sizing of energy storage for wind power plants in a market system , 2003 .

[9]  G. Joos,et al.  A Stochastic Optimization Approach to Rating of Energy Storage Systems in Wind-Diesel Isolated Grids , 2009, IEEE Transactions on Power Systems.

[10]  Rong-Ceng Leou An economic analysis model for the energy storage system applied to a distribution substation , 2012 .

[11]  G. F. Reed,et al.  Economic analysis of grid level energy storage for the application of load leveling , 2012, 2012 IEEE Power and Energy Society General Meeting.

[12]  Bangyin Liu,et al.  Optimal Allocation and Economic Analysis of Energy Storage System in Microgrids , 2011, IEEE Transactions on Power Electronics.

[13]  P. Bastard,et al.  Impact of energy storage costs on economical performance in a distribution substation , 2005, IEEE Transactions on Power Systems.