Simulation and performance analysis of a new LVRT and damping control scheme for DFIG wind turbines

Doubly-Fed Induction Generator (DFIG) Wind Turbine (WT) is rather sensitive to power system faults and requires specific power converter protection, namely a crowbar. When the crowbar is triggered, the rotor is short circuited over the crowbar impedance, the rotor-side converter (RSC) is incapacitated and therefore the DFIG operates as a squirrel-cage induction generator (SCIG) that tends to drain large amount of reactive power from the grid during fault, potentially causing a voltage drop. Therefore, in order to enhance the transient stability and damping of the electro-mechanical oscillations of a grid-connected DFIG wind farm, in this paper we propose the use of DFIG based Low-voltage Ride Through (LVRT) scheme including crowbar, RSC, GSC (Grid-side converter) and PSS (Power System Stabilizers).

[1]  Luis Marroyo,et al.  Doubly Fed Induction Machine : Modeling and Control for Wind Energy Generation , 2011 .

[2]  S. Mishra,et al.  Improving Stability of a DFIG-Based Wind Power System With Tuned Damping Controller , 2009, IEEE Transactions on Energy Conversion.

[3]  Francesco Grimaccia,et al.  Performance analysis of grid-connected wind turbines , 2014 .

[4]  Yongdong Li,et al.  Improved Crowbar Control Strategy of DFIG Based Wind Turbines for Grid Fault Ride-Through , 2009, 2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition.

[5]  C. W. Taylor,et al.  Model validation for the August 10, 1996 WSCC system outage , 1999 .

[6]  Graham Rogers,et al.  Power System Oscillations , 1999 .

[7]  Francesco Grimaccia,et al.  Improving LVRT characteristics in variable-speed wind power generation by means of fuzzy logic , 2014, 2014 IEEE International Conference on Fuzzy Systems (FUZZ-IEEE).

[8]  Jens Fortmann,et al.  Fault-ride-through requirements for wind power plants in the ENTSO-E network code on requirements for generators , 2015 .

[9]  O. Anaya-Lara,et al.  A power system stabilizer for DFIG-based wind generation , 2006, IEEE Transactions on Power Systems.

[10]  Jon Clare,et al.  Doubly fed induction generator using back-to-back PWM converters and its application to variable-speed wind-energy generation , 1996 .

[11]  Sonia Leva,et al.  Comparison of active crowbar protection schemes for DFIGs wind turbines , 2014, 2014 16th International Conference on Harmonics and Quality of Power (ICHQP).

[12]  J. Schlabbach Low voltage fault ride through criteria for grid connection of wind turbine generators , 2008, 2008 5th International Conference on the European Electricity Market.

[13]  Hortensia Amaris,et al.  Coordinated reactive power management in power networks with wind turbines and FACTS devices , 2011 .

[14]  O. Anaya-Lara,et al.  Influence of Tower Shadow and Wind Turbulence on the Performance of Power System Stabilizers for DFIG-Based Wind Farms , 2008, IEEE Transactions on Energy Conversion.

[15]  Francesco Grimaccia,et al.  Pitch angle control using hybrid controller for all operating regions of SCIG wind turbine system , 2014 .

[16]  Martin Braun,et al.  Optimizing the generator start-up sequence after a power system blackout , 2014, 2014 IEEE PES General Meeting | Conference & Exposition.