A new protocol to compare successful versus failed patients using the electromyographic diaphragm signal in extubation process

In clinical practice, when a patient is undergoing mechanical ventilation, it is important to identify the optimal moment for extubation, minimizing the risk of failure. However, this prediction remains a challenge in the clinical process. In this work, we propose a new protocol to study the extubation process, including the electromyographic diaphragm signal (diaEMG) recorded through 5–channels with surface electrodes around the diaphragm muscle. First channel corresponds to the electrode on the right. A total of 40 patients in process of withdrawal of mechanical ventilation, undergoing spontaneous breathing tests (SBT), were studied. According to the outcome of the SBT, the patients were classified into two groups: successful (SG: 19 patients) and failure (FG: 21 patients) groups. Parameters extracted from the envelope of each channel of diaEMG in time and frequency domain were studied. After analyzing all channels, the second presented maximum differences when comparing the two groups of patients, with parameters related to root mean square (p = 0.005), moving average (p = 0.001), and upward slope (p = 0.017). The third channel also presented maximum differences in parameters as the time between maximum peak (p = 0.004), and the skewness (p = 0.027). These results suggest that diaphragm EMG signal could contribute to increase the knowledge of the behaviour of respiratory system in these patients and improve the extubation process.Clinical Relevance—This establishes the characterization of success and failure patients in the extubation process.

[1]  Jair A. Villanueva,et al.  Surface respiratory electromyography and dyspnea in acute heart failure patients , 2020, PloS one.

[2]  Miguel A. Labrador,et al.  Use of Wearable Sensor Technology in Gait, Balance, and Range of Motion Analysis , 2019, Applied Sciences.

[3]  Javier Rodriguez,et al.  A Novel Artifact Reconstruction Method Applied to Blood Pressure Signals , 2018, 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[4]  Marco E. Benalcázar,et al.  Hand gesture recognition using machine learning and the Myo armband , 2017, 2017 25th European Signal Processing Conference (EUSIPCO).

[5]  Xi Zhu,et al.  Weaning critically ill patients from mechanical ventilation: A prospective cohort study. , 2015, Journal of critical care.

[6]  M. Polkey,et al.  Neural respiratory drive predicts clinical deterioration and safe discharge in exacerbations of COPD , 2015, Thorax.

[7]  Sahar Moghimi,et al.  SEMG-based prediction of masticatory kinematics in rhythmic clenching movements , 2015 .

[8]  P. Caminal,et al.  Classification of patients undergoing weaning from mechanical ventilation using the coherence between heart rate variability and respiratory flow signal , 2015, Physiological measurement.

[9]  C. Chung,et al.  Differences in Clinical Outcomes According to Weaning Classifications in Medical Intensive Care Units , 2015, PloS one.

[10]  H. Ellis,et al.  The Respiratory Pathway, Lungs, Thoracic Wall and Diaphragm , 2014 .

[11]  Sergio Herrera,et al.  Study of the oscillatory breathing pattern in elderly patients , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[12]  Abdulhamit Subasi,et al.  Classification of EMG signals using PSO optimized SVM for diagnosis of neuromuscular disorders , 2013, Comput. Biol. Medicine.

[13]  F. Hug,et al.  Dyspnea and surface inspiratory electromyograms in mechanically ventilated patients , 2013, Intensive Care Medicine.

[14]  Gokay Gungor,et al.  Depressive disorders during weaning from prolonged mechanical ventilation , 2010, Intensive Care Medicine.

[15]  Nissan Kunju,et al.  EMG Signal Analysis for Identifying Walking Patterns of Normal Healthy Individuals , 2009 .

[16]  Jacques Duchêne,et al.  Reliability of muscle fibre conduction velocity distribution estimation from surface EMG , 2008, Biomed. Signal Process. Control..

[17]  Shih-Tsang Tang,et al.  A bionic hand controlled by hand gesture recognition based on surface EMG signals: A preliminary study , 2018 .