Implementation and test of on-line embedded grid impedance estimation for PV-inverters

New and stronger power quality requirements are issued due to the increase amount of photovoltaic (PV) installations. In this paper different methods are used for continuous grid monitoring. By injecting a noncharacteristic harmonic current and measuring the grid voltage response it is possible to evaluate the grid impedance directly by the PV-inverter, providing a fast and low cost implementation. This principle theoretically provides a correct result of the grid impedance but when using it into the context of PV integration, different implementation issues strongly affect the quality of the results. This paper presents a new impedance estimation method including typical implementation problems encountered and it also presents adopted solutions for on-line grid impedance measurement. Practical tests on an existing PV-inverter validate the chosen solutions.

[1]  Z. Staroszczyk Problems in real-time wide band identification of power systems , 1998, IMTC/98 Conference Proceedings. IEEE Instrumentation and Measurement Technology Conference. Where Instrumentation is Going (Cat. No.98CH36222).

[2]  Z. Staroszczyk,et al.  Real-time power system linear model identification: instrumentation and algorithms , 2000, Proceedings of the 17th IEEE Instrumentation and Measurement Technology Conference [Cat. No. 00CH37066].

[3]  F. Blaabjerg,et al.  A new method of on-line grid impedance estimation for PV inverter , 2004, Nineteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2004. APEC '04..

[4]  Niels Kjølstad Poulsen,et al.  Short-circuit impedance measurement , 2003 .

[5]  Mark Sumner,et al.  System impedance measurement for use with active filter control , 2000 .

[6]  Neville R. Watson,et al.  Power System Quality Assessment , 2000 .

[7]  Keiju Matsui,et al.  On-line impedance meter to measure the impedance of a distribution line using inverter , 2001, IECON'01. 27th Annual Conference of the IEEE Industrial Electronics Society (Cat. No.37243).

[8]  J. P. Rhode,et al.  Complete characterization of utilization-voltage power system impedance using wideband measurement , 1996, Proceedings of 1996 IAS Industrial and Commercial Power Systems Technical Conference.

[9]  M. Baran,et al.  Instrumentation for measurement of line impedance , 1994, Proceedings of 1994 IEEE Applied Power Electronics Conference and Exposition - ASPEC'94.

[10]  Keiju Matsui,et al.  Development of an on-line impedance meter to measure the impedance of a distribution line , 2001, ISIE 2001. 2001 IEEE International Symposium on Industrial Electronics Proceedings (Cat. No.01TH8570).

[11]  Leszek S. Czarnecki,et al.  On-line measurement of equivalent parameters of distribution system and its load for harmonic frequencies , 1995, Proceedings of 1995 IEEE Instrumentation and Measurement Technology Conference - IMTC '95.

[12]  Mark Sumner,et al.  Power system impedance measurement using a power electronic converter , 2000, Ninth International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.00EX441).