In Situ Measurement of Tissue Impedance Using an Inductive Coupling Interface Circuit

In this work, a method of an inductive coupling impedance measurement (ICIM) is proposed for measuring the nerve impedance of a dorsal root ganglion (DRG) under PRF stimulation. ICIM provides a contactless interface for measuring the reflected impedance by an impedance analyzer with a low excitation voltage of 7 mV. The paper develops a calibration procedure involving a 50-Ω reference resistor to calibrate the reflected resistance for measuring resistance of the nerve in the test. A de-embedding technique to build the equivalent transformer circuit model for the ICIM circuit is also presented. A batteryless PRF stimulator with ICIM circuit demonstrated good accuracy for the acute measurement of DRG impedance both in situ and in vivo. Besides, an in vivo animal experiment was conducted to show that the effectiveness of pulsed radiofrequency (PRF) stimulation in relieving pain gradually declined as the impedance of the stimulated nerve increased. The experiment also revealed that the excitation voltage for measuring impedance below 25 mV can prevent the excitation of a nonlinear response of DRG.

[1]  T. Yaksh,et al.  Quantitative assessment of tactile allodynia in the rat paw , 1994, Journal of Neuroscience Methods.

[2]  Z. Bajwa,et al.  Response to pulsed and continuous radiofrequency lesioning of the dorsal root ganglion and segmental nerves in patients with chronic lumbar radicular pain. , 2008, Pain physician.

[3]  C. Lau,et al.  Intrathoracic Impedance Monitoring in Patients With Heart Failure: Correlation With Fluid Status and Feasibility of Early Warning Preceding Hospitalization , 2005, Circulation.

[4]  Maysam Ghovanloo,et al.  Design and Optimization of a 3-Coil Inductive Link for Efficient Wireless Power Transmission , 2011, IEEE Transactions on Biomedical Circuits and Systems.

[5]  Y. Tai,et al.  Wireless Intraocular Pressure Sensing Using Microfabricated Minimally Invasive Flexible-Coiled LC Sensor Implant , 2010, Journal of Microelectromechanical Systems.

[6]  Mart Min,et al.  Improvement of Lock-in Electrical Bio-Impedance Analyzer for Implantable Medical Devices , 2007, IEEE Transactions on Instrumentation and Measurement.

[7]  W. Tang,et al.  Measuring impedance in congestive heart failure: current options and clinical applications. , 2009, American heart journal.

[8]  Maysam Ghovanloo,et al.  A compact large Voltage-compliance high output-impedance programmable current source for implantable microstimulators , 2005, IEEE Transactions on Biomedical Engineering.

[9]  Mart Min,et al.  An implantable analyzer of bio-impedance dynamics: mixed signal approach [telemetric monitors] , 2002, IEEE Trans. Instrum. Meas..

[10]  Timothy G. Constandinou,et al.  A partial-current-steering biphasic stimulation driver for neural prostheses , 2008, 2008 IEEE International Symposium on Circuits and Systems.

[11]  Maysam Ghovanloo,et al.  Design and Optimization of Printed Spiral Coils for Efficient Transcutaneous Inductive Power Transmission , 2007, IEEE Transactions on Biomedical Circuits and Systems.

[12]  Bernhard Fahn,et al.  Device-based impedance measurement is a useful and accurate tool for direct assessment of intrathoracic fluid accumulation in heart failure. , 2010, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[13]  Jin Mo Chung,et al.  An experimental model for peripheral neuropathy produced by segmental spinal nerve ligation in the rat , 1992, PAIN.

[14]  M P Mintchev,et al.  Design, implementation and testing of an implantable impedance-based feedback-controlled neural gastric stimulator , 2011, Physiological measurement.

[15]  Jean Delbeke,et al.  Time course of tissue remodelling and electrophysiology in the rat sciatic nerve after spiral cuff electrode implantation , 2007, Journal of Neuroimmunology.

[16]  Andreas Demosthenous,et al.  A Stimulator ASIC Featuring Versatile Management for Vestibular Prostheses , 2011, IEEE Transactions on Biomedical Circuits and Systems.

[17]  John L. Wyatt,et al.  A Power-Efficient Neural Tissue Stimulator With Energy Recovery , 2011, IEEE Transactions on Biomedical Circuits and Systems.

[18]  Mohamad Sawan,et al.  Exponential Current Pulse Generation for Efficient Very High-Impedance Multisite Stimulation , 2011, IEEE Transactions on Biomedical Circuits and Systems.

[19]  Maysam Ghovanloo,et al.  Modeling and Optimization of Printed Spiral Coils in Air, Saline, and Muscle Tissue Environments , 2009, IEEE Transactions on Biomedical Circuits and Systems.

[20]  Jun Ohta,et al.  Development and in vivo Demonstration of CMOS-Based Multichip Retinal Stimulator With Simultaneous Multisite Stimulation Capability , 2010, IEEE Transactions on Biomedical Circuits and Systems.

[21]  David H. S. Cheng The Reflected Impedance of a Circular Coil in the Proximity of a Semi-Infinite Medium , 1965 .

[22]  R. Meyer,et al.  Mechanical hyperalgesia after an L5 spinal nerve lesion in the rat is not dependent on input from injured nerve fibers , 2000, Pain.

[23]  H. Cho,et al.  A three-step method for the de-embedding of high-frequency S-parameter measurements , 1991 .

[24]  Luigi Raffo,et al.  Peripheral Neural Activity Recording and Stimulation System , 2011, IEEE Transactions on Biomedical Circuits and Systems.

[25]  Esther Rodríguez-Villegas,et al.  A tissue impedance measurement chip for myocardial ischemia detection , 2005, IEEE Transactions on Circuits and Systems I: Regular Papers.

[26]  S. Rapoport,et al.  AC impedance of the perineurium of the frog sciatic nerve. , 1984, Biophysical journal.

[27]  Seulki Lee,et al.  A Wirelessly Powered Electro-Acupuncture Based on Adaptive Pulsewidth Monophase Stimulation , 2011, IEEE Transactions on Biomedical Circuits and Systems.

[28]  Andreas Demosthenous,et al.  High-Power Integrated Stimulator Output Stages With Floating Discharge Over a Wide Voltage Range for Nerve Stimulation , 2010, IEEE Transactions on Biomedical Circuits and Systems.

[29]  K. Arabi,et al.  A new technique to monitor the electrode and lead failures in implantable microstimulators and sensors , 1996, Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[30]  Shahriar Mirabbasi,et al.  Design and Optimization of Resonance-Based Efficient Wireless Power Delivery Systems for Biomedical Implants , 2011, IEEE Transactions on Biomedical Circuits and Systems.

[31]  Maurits Ortmanns,et al.  An Active Approach for Charge Balancing in Functional Electrical Stimulation , 2010, IEEE Transactions on Biomedical Circuits and Systems.

[32]  Thermpon Ativanichayaphong,et al.  An implantable batteryless wireless impedance sensor for gastroesophageal reflux diagnosis , 2010, 2010 IEEE MTT-S International Microwave Symposium.

[33]  Chii-Wann Lin,et al.  Pain Control on Demand Based on Pulsed Radio-Frequency Stimulation of the Dorsal Root Ganglion Using a Batteryless Implantable CMOS SoC. , 2010, IEEE transactions on biomedical circuits and systems.

[34]  U. Oron,et al.  Three-dimensional endocardial impedance mapping: a new approach for myocardial infarction assessment. , 2001, American journal of physiology. Heart and circulatory physiology.

[35]  Ramon Bragós,et al.  Transmural versus nontransmural in situ electrical impedance spectrum for healthy, ischemic, and healed myocardium , 2004, IEEE Transactions on Biomedical Engineering.

[36]  Daryl R Kipke,et al.  Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants , 2007, Journal of neural engineering.

[37]  T. Brennan,et al.  Immediate early genes after pulsed radiofrequency treatment: neurobiology in need of clinical trials. , 2005, Anesthesiology.

[38]  Reid R. Harrison,et al.  A Wireless Integrated Circuit for 100-Channel Charge-Balanced Neural Stimulation , 2009, IEEE Transactions on Biomedical Circuits and Systems.