MRI assessment of thoracic stent grafts after emergency implantation in multi trauma patients: a feasibility study

PurposeTo evaluate the feasibility of MRI for static and dynamic assessment of the deployment of thoracic aortic stent grafts after emergency implantation in trauma patients.MethodsTwenty patients initially presenting with a rupture of the thoracic aorta were enrolled in this study. All patients underwent thoracic endovascular aortic repair (TEVAR). The deployment of the implanted stent graft was assessed by CTA and MRI, comprising the assessment of the aortic arch with and without contrast agent, and the assessment of the motion of the stent graft over the cardiac cycle.ResultsThe stent graft geometry and motion over the cardiac cycle were assessable by MRI in all patients. Flow-mediated signal variations in areas of flow acceleration could be well visualised. No statistically significant differences in stent-graft diameters were observed between CT and MRI measurements.ConclusionMRI appears to be a valuable tool for the assessment of thoracic stent grafts. It shows similar performance in the accurate assessment of stent-graft dimensions to the current gold standard CTA. Its capability of providing additional functional information and the lack of ionising radiation and nephrotoxic contrast agents may make MRI a valuable tool for monitoring patients after TEVAR.

[1]  Ron Kikinis,et al.  3D Slicer , 2012, 2004 2nd IEEE International Symposium on Biomedical Imaging: Nano to Macro (IEEE Cat No. 04EX821).

[2]  J. Carr,et al.  Dark-blood MRI of the thoracic aorta with 3D diffusion-prepared steady-state free precession: initial clinical evaluation. , 2007, AJR. American journal of roentgenology.

[3]  Koen L Vincken,et al.  Aortic Compliance following EVAR and the Influence of Different Endografts: Determination Using Dynamic MRA , 2006, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[4]  F G Shellock,et al.  Metallic stents: evaluation of MR imaging safety. , 1999, AJR. American journal of roentgenology.

[5]  J. Reekers,et al.  Emergency Endovascular Treatment of Thoracic Aortic Rupture in Three Accident Victims with Multiple Injuries , 2002, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[6]  W. Heindel,et al.  Thoracic aortic stent graft: comparison of contrast-enhanced MR angiography and CT angiography in the follow-up: initial results , 2003, European Radiology.

[7]  Y. Amano,et al.  Non–contrast‐enhanced MR angiography of the thoracic aorta using cardiac and navigator‐gated magnetization‐prepared three‐dimensional steady‐state free precession , 2008, Journal of magnetic resonance imaging : JMRI.

[8]  H. Quick,et al.  In vitro image characteristics of an abdominal aortic stent graft: CTA versus 3D MRA , 2007, Magnetic Resonance Materials in Physics, Biology and Medicine.

[9]  J. Finn,et al.  MR imaging of the thoracic aorta. , 2008, Magnetic Resonance Imaging Clinics of North America.

[10]  G. Halter,et al.  Endovascular treatment (EVT) of acute traumatic lesions of the descending thoracic aorta--7 years' experience. , 2007, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[11]  R. Günther,et al.  Artifact-Free In-Stent Lumen Visualization by Standard Magnetic Resonance Angiography Using a New Metallic Magnetic Resonance Imaging Stent , 2002, Circulation.

[12]  G. Schneider MR Angiography of the Thoracic Aorta , 2005 .

[13]  W. Heindel,et al.  3.0 Tesla Magnetic Resonance Angiography of Endovascular Aortic Stent Grafts: Phantom Measurements in Comparison With 1.5 Tesla , 2004, Investigative radiology.

[14]  J. Dehmeshki,et al.  Variability of ascending aorta diameter measurements as assessed with electrocardiography-gated multidetector computerized tomography and computer assisted diagnosis software. , 2010, Interactive Cardiovascular and Thoracic Surgery.

[15]  William E. Lorensen,et al.  The NA-MIC Kit: ITK, VTK, pipelines, grids and 3D slicer as an open platform for the medical image computing community , 2006, 3rd IEEE International Symposium on Biomedical Imaging: Nano to Macro, 2006..

[16]  M. Douglas,et al.  Immediate endovascular repair for descending thoracic aortic transection secondary to blunt trauma. , 2000, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[17]  G. Wheatley,et al.  Guidelines for credentialing of practitioners to perform endovascular stent-grafting of the thoracic aorta. , 2006, The Annals of thoracic surgery.

[18]  J. Reekers,et al.  Endovascular management of traumatic ruptures of the thoracic aorta: a retrospective multicenter analysis of 28 cases in The Netherlands. , 2006, Journal of vascular surgery.

[19]  E. Merkle,et al.  Magnetic Resonance Imaging versus Multislice Computed Tomography of Thoracic Aortic Endografts , 2002, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[20]  O. Weber,et al.  Phase contrast MR imaging to measure changes in collateral blood flow after stenting of recurrent aortic coarctation: Initial experience , 2006, Journal of magnetic resonance imaging : JMRI.

[21]  P. Weale,et al.  Unenhanced MR angiography of the thoracic aorta: initial clinical evaluation. , 2008, AJR. American journal of roentgenology.

[22]  T. Grobner Gadolinium--a specific trigger for the development of nephrogenic fibrosing dermopathy and nephrogenic systemic fibrosis? , 2006, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[23]  L. Sunder-Plassmann,et al.  Stentgrafting of the thoracic aorta-complications. , 2005, The Journal of cardiovascular surgery.

[24]  W. Eric L. Grimson,et al.  An Integrated Visualization System for Surgical Planning and Guidance Using Image Fusion and Interventional Imaging , 1999, MICCAI.

[25]  P. Hutchin,et al.  ACQUIRED ESOPHAGOBRONCHIAL FISTULA OF INFECTIOUS ORIGIN. , 1964, The Journal of thoracic and cardiovascular surgery.

[26]  H. Rousseau,et al.  Acute traumatic aortic rupture: a comparison of surgical and stent-graft repair. , 2005, The Journal of thoracic and cardiovascular surgery.

[27]  R. S. Mitchell,et al.  Expert consensus document on the treatment of descending thoracic aortic disease using endovascular stent-grafts. , 2008, The Annals of thoracic surgery.

[28]  Lone Skov,et al.  Nephrogenic systemic fibrosis: suspected causative role of gadodiamide used for contrast-enhanced magnetic resonance imaging. , 2006, Journal of the American Society of Nephrology : JASN.

[29]  E. Merkle,et al.  MR angiographic findings in patients with aortic endoprostheses. , 2002, AJR. American journal of roentgenology.

[30]  E. Larsson,et al.  Magnetic resonance imaging and MR angiography of endoluminally treated abdominal aortic aneurysms. , 1998, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[31]  E. Larsson,et al.  MR Evaluation Ex Vivo and In Vivo of a Covered Stent‐Graft for Abdominal Aortic Aneurysms: Ferromagnetism, Heating, Artifacts, and Velocity Mapping , 2000, Journal of magnetic resonance imaging : JMRI.

[32]  R. Bonser,et al.  Reproducibility of thoracic aortic diameter measurement using computed tomographic scans. , 1999, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[33]  Karen Ordovas,et al.  Velocity-encoded cine MR imaging in aortic coarctation: functional assessment of hemodynamic events. , 2008, Radiographics : a review publication of the Radiological Society of North America, Inc.

[34]  T Klemm,et al.  MR imaging in the presence of vascular stents: A systematic assessment of artifacts for various stent orientations, sequence types, and field strengths , 2000, Journal of magnetic resonance imaging : JMRI.