Spectral detector CT-derived virtual non-contrast images: comparison of attenuation values with unenhanced CT

PurposeTo assess virtual non-contrast (VNC) images obtained on a detection-based spectral detector CT scanner and determine how attenuation on VNC images derived from various phases of enhanced CT compare to those obtained from true unenhanced images.MethodsIn this HIPAA compliant, IRB approved prospective multi-institutional study, 46 patients underwent pre- and post-contrast imaging on a prototype dual-layer spectral detector CT between October 2013 and November 2015, yielding 84 unenhanced and VNC pairs (25 arterial, 39 portal venous/nephrographic, 20 urographic). Mean attenuation was measured by one of three readers in the liver, spleen, kidneys, psoas muscle, abdominal aorta, and subcutaneous fat. Equivalence testing was used to determine if the mean difference between unenhanced and VNC attenuation was less than 5, 10, or 15 HU. VNC image quality was assessed on a 5 point scale.ResultsMean difference between unenhanced and VNC attenuation was <15 HU in 92.6%, <10 HU in 75.2%, and <5 HU in 44.4% of all measurements. Unenhanced and VNC attenuation were equivalent in all tissues except fat using a threshold of <10 HU difference (p < 0.05). No significant variation was seen between phases. In fat, VNC overestimated the HU relative to unenhanced images. VNC image quality was rated as excellent or good in 84% of arterial phase and 85% of nephrographic phase cases, but only 40% of urographic phase.ConclusionVNC images derived from novel dual layer spectral detector CT demonstrate attenuation values similar to unenhanced images in all tissues evaluated except for subcutaneous fat. Further study is needed to determine if attenuation thresholds currently used clinically for common pathology should be adjusted, particularly for lesions containing fat.

[1]  P. Choyke ACR Appropriateness Criteria on incidentally discovered adrenal mass. , 2006, Journal of the American College of Radiology : JACR.

[2]  C. Claussen,et al.  Tin-filter enhanced dual-energy-CT: image quality and accuracy of CT numbers in virtual noncontrast imaging. , 2013, Academic radiology.

[3]  B. K. Park,et al.  Adenoma characterization: adrenal protocol with dual-energy CT. , 2013, Radiology.

[4]  S. Silverman,et al.  Virtual unenhanced CT images acquired from dual-energy CT urography: accuracy of attenuation values and variation with contrast material phase. , 2013, Clinical radiology.

[5]  R. Brooks,et al.  Split-detector computed tomography: a preliminary report. , 1978, Radiology.

[6]  M. Rengo,et al.  Dual energy CT (DECT) of the liver: conventional versus virtual unenhanced images , 2010, European Radiology.

[7]  Florian Wolf,et al.  Virtual non-contrast in second-generation, dual-energy computed tomography: reliability of attenuation values. , 2012, European journal of radiology.

[8]  C. McCollough,et al.  Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications. , 2015, Radiology.

[9]  Christoph Thomas,et al.  Virtual nonenhanced dual-energy CT urography with tin-filter technology: determinants of detection of urinary calculi in the renal collecting system. , 2012, Radiology.

[10]  James A Brink,et al.  Managing incidental findings on abdominal CT: white paper of the ACR incidental findings committee. , 2010, Journal of the American College of Radiology : JACR.

[11]  Christianne Leidecker,et al.  Dual-energy CT in patients suspected of having renal masses: can virtual nonenhanced images replace true nonenhanced images? , 2009, Radiology.

[12]  K. Stierstorfer,et al.  First performance evaluation of a dual-source CT (DSCT) system , 2006, European Radiology.

[13]  Evaluation of virtual unenhanced CT obtained from dual-energy CT urography for detecting urinary stones. , 2012, The British journal of radiology.

[14]  A. Macovski,et al.  Energy-selective reconstructions in X-ray computerised tomography , 1976, Physics in medicine and biology.

[15]  X. Montet,et al.  Incidental adrenal lesions detected on enhanced abdominal dual-energy CT: can the diagnostic workup be shortened by the implementation of virtual unenhanced images? , 2014, European journal of radiology.

[16]  G. Hounsfield Computerized transverse axial scanning (tomography): Part I. Description of system. 1973. , 1973, The British journal of radiology.

[17]  G. Hounsfield Computerized transverse axial scanning (tomography). 1. Description of system. , 1973, The British journal of radiology.