Deactivated hydrocarbonaceous silica and immobilized artificial membrane stationary phases in high-performance liquid chromatographic determination of hydrophobicities of organic bases: relationship to log P and CLOGP.

Retention parameters for a series of 29 organic base drugs (including 17 phenothiazine derivatives) were measured by reversed-phase high-performance liquid chromatography (HPLC) employing new columns of distinctive partition properties. One column was a deactivated alkyl-bonded silica and two others were packed with lecithin-bonded propylamino-silica, i.e. the immobilized artificial membrane (IAM) columns; one of the IAM stationary phases had the unreacted propylamine moieties additionally end-capped with methylglycolate. The highly deactivated hydrocarbonaceous silica column showed regular rectilinear relationships between logarithms of chromatographic capacity factors and the content of organic modifier in aqueous eluent; it is suitable for generating a chromatographic scale of hydrophobicity. Such a scale (hydrocarbonaceous) is different from that provided by measurement of partitioning of solutes between n-octanol and water (alkanol log P scale). The relative hydrophobicity parameters determined by HPLC on the IAM columns were different from both log P scale and from the hydrocarbonaceous chromatographic hydrophobicity scale. The hydrophobicity parameter, CLOGP, theoretically calculated by the fragmental methods, correlated better than log P with chromatographic hydrophobicity parameters. It has been postulated that each hydrophobicity measuring system reveals some specific aspects of the hydrophobicity phenomenon and that the nature of hydrophobic binding sites on receptors and plasma proteins may require different hydrophobicity models than drug permeation through biological membranes. By means of HPLC, diverse hydrophobicity measures can readily be determined, among which those most suitable for specific QSAR applications can be identified.

[1]  C. Hansch,et al.  p-σ-π Analysis. A Method for the Correlation of Biological Activity and Chemical Structure , 1964 .

[2]  H. Terada,et al.  Phosphatidylcholine-coated silica as a useful stationary phase for high-performance liquid chromatographic determination of partition coefficients between octanol and water , 1987 .

[3]  C. Hansch,et al.  SUBSTITUENT CONSTANTS FOR ALIPHATIC FUNCTIONS OBTAINED FROM PARTITION COEFFICIENTS. , 1965, Journal of medicinal chemistry.

[4]  L. Snyder,et al.  Characterization of silica-based reversed-phase columns with respect to retention selectivity : Solvophobic effects , 1985 .

[5]  E. Tomlinson Chromatographic hydrophobic parameters in correlation analysis of structure-activity relationships. , 1975, Journal of chromatography.

[6]  R. Kaliszan,et al.  Chromatographic data for pharmacological classification of imidazol(in)e drugs. , 1991, Journal of chromatography.

[7]  T. Ascah,et al.  Novel, highly deactivated reversed-phase for basic compounds , 1990 .

[8]  C. Eadsforth Application of reverse-phase h.p.l.c. for the determination of partition coefficients† , 1986 .

[9]  A. Leo,et al.  Some advantages of calculating octanol-water partition coefficients. , 1987, Journal of pharmaceutical sciences.

[10]  W. P. Purcell,et al.  Mechanism of retention of benzodiazepines in affinity, reversed-phase and adsorption high-performance liquid chromatography in view of quantitative structure retention relationships , 1992 .

[11]  R. Kaliszan Chromatography in studies of quantitative structure-activity relationships. , 1981, Journal of chromatography.

[12]  C. Pidgeon,et al.  Immobilized artificial membrane chromatography: supports composed of membrane lipids. , 1989, Analytical biochemistry.

[13]  R. Kaliszan High Performance Liquid Chromatographic Methods and Procedures of Hydrophobicity Determination , 1990 .

[14]  J. Knox,et al.  Theory of solvent disturbance peaks and experimentaldetermination of thermodynamic dead-volume in column liquid chromatography , 1985 .