Two-dimensional photoacoustic imaging by use of Fourier-transform image reconstruction and a detector with an anisotropic response.

Theoretical and experimental aspects of two-dimensional (2D) biomedical photoacoustic imaging have been investigated. A 2D Fourier-transform-based reconstruction algorithm that is significantly faster and produces fewer artifacts than simple radial backprojection methods is described. The image-reconstruction time for a 208 x 482 pixel image is approximately 1 s. For the practical implementation of 2D photoacoustic imaging, a rectangular detector geometry was used to obtain an anisotropic detection sensitivity in order to reject out-of-plane signals, thereby permitting a tomographic image slice to be reconstructed. This approach was investigated by the numerical modeling of the broadband directional response of a rectangular detector and imaging of various spatially calibrated absorbing targets immersed in a turbid phantom. The experimental setup was based on a Q-switched Nd:YAG excitation laser source and a mechanically line-scanned Fabry-Perot polymer-film ultrasound sensor. For a 800 microm x 200 microm rectangular detector, the reconstructed image slice thickness was 0.8 mm up to a vertical distance of z = 3.5 mm from the detector, increasing thereafter to 2 mm at z = 10 mm. Horizontal and vertical spatial resolutions within the reconstructed slice were approximately 200 and 60 microm, respectively.

[1]  Stephen W. Smith,et al.  Beam Steering with Linear Arrays , 1983, IEEE Transactions on Biomedical Engineering.

[2]  Gerald J. Diebold,et al.  PROPERTIES OF PHOTOACOUSTIC WAVES IN ONE, TWO, AND THREE DIMENSIONS , 1994 .

[3]  F. D. de Mul,et al.  Three-dimensional photoacoustic imaging of blood vessels in tissue. , 1998, Optics letters.

[4]  F. Perennes,et al.  Transduction mechanisms of the Fabry-Perot polymer film sensing concept for wideband ultrasound detection , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  A. Aisen,et al.  Thermoacoustic CT with radio waves: a medical imaging paradigm. , 1999, Radiology.

[6]  P. Beard,et al.  Characterization of a polymer film optical fiber hydrophone for use in the range 1 to 20 MHz: A comparison with PVDF needle and membrane hydrophones , 2000, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  Paul C. Beard,et al.  2D line-scan photoacoustic imaging of absorbers in a scattering tissue phantom , 2001, SPIE BiOS.

[8]  H. Weber,et al.  Optoacoustic imaging using a three-dimensional reconstruction algorithm , 2001 .

[9]  H. Weber,et al.  Temporal backward projection of optoacoustic pressure transients using fourier transform methods. , 2001, Physics in medicine and biology.

[10]  H Schmidt-Kloiber,et al.  Optoacoustic tomography: time-gated measurement of pressure distributions and image reconstruction. , 2001, Applied optics.

[11]  Roy G. M. Kolkman,et al.  Photoacoustic monitoring and imaging of blood vessels in tissue , 2002, SPIE BiOS.

[12]  Zhongping Chen,et al.  Clinical testing of a photoacoustic probe for port wine stain depth determination , 2002, Lasers in surgery and medicine.

[13]  Paul C. Beard Photoacoustic imaging of blood vessel equivalent phantoms , 2002, SPIE BiOS.

[14]  Alexander A. Oraevsky,et al.  Optoacoustic imaging of blood for visualization and diagnostics of breast cancer , 2002, SPIE BiOS.