In vivo strain measurements from hardware and lamina during spine fusion.

Currently, spine fusion is determined using radiography and clinical evaluation. There are discrepancies between radiographic evidence and direct measurements of fusion, such as operative exploration and biomechanical or histological measurements. In order to facilitate the rapid return of patients to normal activities, a monitoring technique to accurately detect fusion in vivo and to prevent overload during the postoperative period would be useful. The objectives of this study were to develop an implantable monitoring system consisting of CPC-coated strain gauges and a radio transmitter to detect the onset of fusion and measure strain during postsurgical activities. A patient underwent anterior release and fusion, followed by posterior instrumentation and fusion with segmental spinal instrumentation. Four strain gauges were placed during surgery. One was attached to the left-side rod and one to each of the lamina at T9, T10, and T11. An externally powered implanted radio transmitter attached to the gauges was placed in a subcutaneous pouch. Strains were monitored weekly and tabulated during various activities for 7 months. Peak strains during twisting and bending were tabulated to detect the onset of fusion. Strains were also recorded during activities such as climbing off an examination table, rising from a chair, and climbing stairs. Strains collected from the left rod indicated that, immediately postoperatively, it was loaded at acceptable levels. The largest and most consistent strain changes measured from the lamina were recorded during twisting.

[1]  R B Ashman,et al.  Effect of Spinal Construct Stiffness on Early Fusion Mass Incorporation Experimental Study , 1990, Spine.

[2]  D. Nagel,et al.  Biochemistry of fusion mass consolidation in the sheep spine , 1988, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[3]  J. Szivek,et al.  Long-term measurement of bone strain in vivo: the rat tibia. , 2001, Journal of biomedical materials research.

[4]  R. Jackson,et al.  Enhancement of Lumbar Spine Fusion by Use of Translaminar Facet Joint Screws , 1989, Spine.

[5]  M M Panjabi,et al.  Biomechanical Evaluation of Spinal Fixation Devices: II. Stability Provided by Eight Internal Fixation Devices , 1988, Spine.

[6]  J. Szivek,et al.  In vivo strain measurements collected using calcium phosphate ceramic-bonded strain gauges. , 1997, Journal of investigative surgery : the official journal of the Academy of Surgical Research.

[7]  H. Lipscomb,et al.  Spinal Bone Density Following Spinal Fusion , 1989, Spine.

[8]  J. Szivek,et al.  Interface strength studies of calcium phosphate ceramic coated strain gauges. , 1998, Journal of biomedical materials research.

[9]  A. E. Brodsky,et al.  Correlation of Radiologic Assessment of Lumbar Spine Fusions with Surgical Exploration , 1991, Spine.

[10]  S. Esses,et al.  Operative Treatment of Spinal Fractures with the AO Internal Fixator , 1991, Spine.

[11]  R. Jacobs,et al.  Internal fixation in lumbosacral spine fusion. A biomechanical and clinical study. , 1986, Clinical orthopaedics and related research.

[12]  A Rohlmann,et al.  Monitoring In Vivo Implant Loads With a Telemeterized Internal Spinal Fixation Device , 2000, Spine.

[13]  F. P. Magee,et al.  In vivo strain analysis of the greyhound femoral diaphysis. , 1992, Journal of investigative surgery : the official journal of the Academy of Surgical Research.

[14]  A. Patwardhan,et al.  A follower load increases the load-carrying capacity of the lumbar spine in compression. , 1999, Spine.

[15]  M. Hongo,et al.  Surface strain distribution on thoracic and lumbar vertebrae under axial compression. The role in burst fractures. , 1999, Spine.

[16]  K. Gill,et al.  Can lumbar spine radiographs accurately determine fusion in postoperative patients? Correlation of routine radiographs with a second surgical look at lumbar fusions. , 1993, Spine.

[17]  T. Dishongh,et al.  Evaluation of factors affecting bonding rate of calcium phosphate ceramic coatings for in vivo strain gauge attachment. , 1996, Journal of biomedical materials research.

[18]  B. Cunningham,et al.  The Effect of Spinal Implant Rigidity on Vertebral Bone Density A Canine Mode , 1991, Spine.

[19]  K. Kaneda,et al.  Maturation of the Posterolateral Spinal Fusion and Its Effect on Load-Sharing of Spinal Instrumentation. An In Vivo Sheep Model* , 1997, The Journal of bone and joint surgery. American volume.

[20]  John A Szivek,et al.  An Implantable Strain Measurement System Designed to Detect Spine Fusion: Preliminary Results From a Biomechanical In Vivo Study , 2002, Spine.

[21]  M M Panjabi,et al.  Biomechanical Evaluation of Spinal Fixation Devices: I. A Conceptual Framework , 1988, Spine.

[22]  F. P. Magee,et al.  Preliminary development of a hydroxyapatite-backed strain gauge. , 1990, Journal of applied biomaterials : an official journal of the Society for Biomaterials.

[23]  E. Koeneman,et al.  An Apparatus for Applying Pure Nonconstraining Moments to Spine Segments In Vitro , 1995, Spine.

[24]  B. Cunningham,et al.  1989 Volvo Award in Basic Science: Device-Related Osteoporosis with Spinal Instrumentation , 1989, Spine.

[25]  J. Szivek,et al.  Bone bonding strength of calcium phosphate ceramic coated strain gauges. , 1999, Journal of biomedical materials research.