Servo-control of plasma position in Cleo-Tokamak
暂无分享,去创建一个
A system for servo-control of the plasma position in a tokamak discharge is described. Measurements of the stability boundary of the servo-loop in the Cleo-Tokamak apparatus are presented and compared with a theoretical model. They show reasonable agreement. Using servo-control, the discharge time was extended from 110 ms to nearly 200 ms, and the plasma remained within ±10 mm of the centre of the vacuum vessel for up to 140 ms. The instability caused by a deliberately applied vertical field with positive gradient was stabilized.
[1] S. Mirnov,et al. Investigation of the instabilities of the plasma string in the Tokamak-3 system by means of a correlation method , 1971 .
[2] J. Junker. Toroidal Plasma Confinement , 1973 .
[3] 青野 修. M.A. Leontovich編: Reviews of Plasma Physics vol.2, Consultants Bureau, New York, 1966, 297頁, 15×23cm, 5,000円 , 1967 .