Dynamic Daylight Performance Metrics for Sustainable Building Design

Abstract The objective of this document is to promote the use of dynamic daylight performance measures for sustainable building design. The paper initially explores the shortcomings of conventional, static daylight performance metrics which concentrate on individual sky conditions, such as the common daylight factor. It then provides a review of previously suggested dynamic daylight performance metrics, discussing the capability of these metrics to lead to superior daylighting designs and their accessibility to nonsimulation experts. Several example offices are examined to demonstrate the benefit of basing design decisions on dynamic performance metrics as opposed to the daylight factor.

[1]  C. Reinhart,et al.  Development and validation of a Radiance model for a translucent panel , 2006 .

[2]  G. W. Larson,et al.  Rendering with radiance - the art and science of lighting visualization , 2004, Morgan Kaufmann series in computer graphics and geometric modeling.

[3]  J. Mardaljevic Examples of Climate-Based Daylight Modelling , 2006 .

[4]  M Bodart,et al.  Design of a new single-patch sky and sun simulator , 2006 .

[5]  offices Reinhart Effects of Interior Design on the Daylight Availability in Open Plan Offices , 2002 .

[6]  Christoph F. Reinhart,et al.  Lightswitch-2002: a model for manual and automated control of electric lighting and blinds , 2004 .

[7]  Percy John Waldram A measuring diagram for daylight illumination for the measurement, predetermination and representation of natural lighting , 1950 .

[8]  T. Inoue,et al.  The development of an optimal control system for window shading devices based on investigations in office buildings , 1988 .

[9]  E. Ne'Eman,et al.  Critical minimum acceptable window size: a study of window design and provision of a view , 1970 .

[10]  Christoph F. Reinhart,et al.  Monitoring manual control of electric lighting and blinds , 2003 .

[11]  P. Tregenza The daylight factor and actual illuminance ratios , 1980 .

[12]  Francis Rubinstein,et al.  Comparison of control options in private offices in an advanced lighting controls testbed , 1999 .

[13]  Jan Asle Olseth,et al.  Observed and modelled hourly luminous efficacies under arbitrary cloudiness , 1989 .

[14]  John Mardaljevic Quantification of parallax errors in sky simulator domes for clear sky conditions , 2002 .

[15]  J. Veitch,et al.  A Room with a View: A Review of the Effects of Windows on Work and Well-Being , 2004 .

[16]  John Mardaljevic,et al.  Useful daylight illuminances: A replacement for daylight factors , 2006 .

[17]  John Mardaljevic,et al.  Simulation of annual daylighting profiles for internal illuminance , 2000 .

[18]  Christoph F. Reinhart,et al.  Findings from a survey on the current use of daylight simulations in building design , 2006 .

[19]  J. Timmer,et al.  Dynamic annual daylight simulations based on one-hour and one-minute means of irradiance data , 2002 .

[20]  M. P. Hattrup Daylighting practices of the architectural industry (baseline results of a national survey) , 1990 .

[21]  M S. Rea,et al.  Window blind occlusion: a pilot study , 1984 .

[22]  Claude Bédard,et al.  Decision support system for compliance checking with the model national energy code of Canada for buildings , 1999 .

[23]  Nicolas Morel,et al.  A field investigation of the intermediate light switching by users , 2006 .

[24]  Kumiko Toishi Daylighting in Museums , 1999 .

[25]  John Mardaljevic,et al.  Useful daylight illuminance: a new paradigm for assessing daylight in buildings , 2005 .