A stable and inexpensive wavelength reference for precise wavelength calibration of radial velocity spectrographs

We present a stable, inexpensive wavelength reference, based on a white-light interferometer for the use on current and future (arrays of) diffraction-limited radial velocity (RV) spectrographs. The primary aim of using an interferometer is to obtain a dense sinusoidal wavelength reference with spectral coverage between 450-650 nm. Its basic setup consists of an unbalanced fiber Mach-Zehnder interferometer (FMZI) that creates an interference pattern in the spectral domain due to superposition of phase delayed light, set by a fixed optical path-length difference (OPD). To achieve long-term stability, the interferometer is actively locked to a stable atomic line. The system operates in closed-loop using a thermo-optic modulator as the phase feedback component. We conducted stability measurements by superimposing the wavelength reference with thorium-argon (ThAr) emission lines and found the differential RMS shift to be ~5 m s-1 within 30 minute bins in an experiment lasting 5 hours.

[1]  Marc L. Salit,et al.  Wave numbers and Ar pressure-induced shifts of 198Hg atomic lines measured by Fourier transform spectroscopy , 2005 .

[2]  Robert K. Y. Chan,et al.  DESIGN NOTE: Single chip optical fibre interferometer thermal phase-quadrature controller , 1996 .

[3]  J. G. Ziegler,et al.  Optimum Settings for Automatic Controllers , 1942, Journal of Fluids Engineering.

[4]  Christian Schwab,et al.  Single Mode, Extreme Precision Doppler Spectrographs , 2012, Proceedings of the International Astronomical Union.

[5]  Suvrath Mahadevan,et al.  Development of a new, precise near-infrared Doppler wavelength reference: a fiber Fabry-Perot interferometer , 2013 .

[6]  Thomas G. Giallorenzi,et al.  Optical fiber sensor technology , 1982, 1985 International Electron Devices Meeting.

[7]  A. Ghasempour,et al.  A single-mode Echelle spectrograph: eliminating modal variation, enabling higher precision Doppler study , 2012, Other Conferences.

[8]  M. Salit,et al.  Investigation of single-factor calibration of the wave-number scale in Fourier-transform spectroscopy , 2004 .

[9]  C J Sansonetti,et al.  Wavelengths of spectral lines in mercury pencil lamps. , 1996, Applied optics.

[10]  D. Narayana Rao,et al.  Using interference in the frequency domain for precise determination of thickness and refractive indices of normal dispersive materials , 1995 .

[11]  Victor de HaanV. deHaan Mach–Zehnder fiber interferometer test of the anisotropy of the speed of light , 2009 .

[12]  G. Walker,et al.  PRECISION RADIAL VELOCITIES WITH AN ABSORPTION CELL. , 1979 .

[13]  S. Rashleigh,et al.  Bending-induced birefringence in single-mode fibers. , 1980, Optics letters.

[14]  Michel Mayor,et al.  ELODIE: A spectrograph for accurate radial velocity measurements , 1996 .