Survey of Harmonics in Non Linear Loads

The use of non linear loads is increasing day by day. This increasing use of non linear loads has created more distortions in current and voltage waveforms. This increased power quality disturbances has lead to various optimizations techniques and filter designs. Harmonic distortions are the major cause for power quality problems. For this analyzing the harmonics present in non linear loads is significant. Here a survey is made to show details of harmonics present in various non linear loads.

[1]  P.N. Enjeti,et al.  Three phase active harmonic rectifier (AHR) to improve utility input current THD in telecommunication power distribution system , 2003, Eighteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2003. APEC '03..

[2]  W. Kling,et al.  An analysis of diversity factors applied to harmonic emission limits for energy saving lamps , 2010, Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010.

[3]  V. Tipsuwanporn,et al.  Harmonics reduction system using active filter based on computer unit , 2005, 2005 IEEE/PES Transmission & Distribution Conference & Exposition: Asia and Pacific.

[4]  Pat Bodger,et al.  Power System Harmonics , 2003 .

[5]  P. Sicard,et al.  Characterization of neutral and line current harmonics in three-phase computer power systems , 2005, 31st Annual Conference of IEEE Industrial Electronics Society, 2005. IECON 2005..

[6]  P. Verde,et al.  Estimating the net harmonic currents produced by selected distributed single-phase loads: computers, televisions, and incandescent light dimmers , 2002, 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309).

[7]  Anne Ko Analysis of Harmonic Distortion in Non-linear Loads , 2011 .

[8]  W. M. Grady,et al.  Predicting the net harmonic currents produced by large numbers of distributed single-phase computer loads , 1995 .

[9]  Rahmat Allah HOOSHMAND,et al.  Optimal Design of TCR / FC in Electric Arc Furnaces for Power Quality Improvement in Power Systems , 2009 .

[10]  Rana A. Jabbar,et al.  Impacts of harmonics caused by Personal Computers on distribution transformers , 2009, 2009 Third International Conference on Electrical Engineering.

[11]  S. Perera,et al.  Harmonic Levels and Television Events , 2007, 2007 IEEE Power Engineering Society General Meeting.

[12]  Frangiskos V. Topalis,et al.  Harmonic distortion in electric power systems introduced by compact fluorescent lamps , 1999, PowerTech Budapest 99. Abstract Records. (Cat. No.99EX376).

[13]  R. K. Tripathi,et al.  Power quality control of unregulated non-linear loads , 2010, 2010 International Conference on Power, Control and Embedded Systems.

[15]  U. Grasselli,et al.  Harmonics monitoring survey on office LV appliances , 2010, Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010.

[16]  M. T. Correia de Barros,et al.  Harmonics and Flicker Analysis in Arc Furnace Power Systems , 2005 .

[17]  L. Cividino,et al.  Power factor, harmonic distortion; causes, effects and considerations , 1992, [Proceedings] Fourteenth International Telecommunications Energy Conference - INTELEC '92.

[18]  E. Gluskin High harmonic currents in fluorescent lamp circuits , 1988, Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting.

[19]  Zarko Janda,et al.  An improved current injection network for three-phase high-power-factor rectifiers that apply the third harmonic current injection , 2000, IEEE Trans. Ind. Electron..

[20]  J. S. Subjak,et al.  Harmonics-causes, effects, measurements and analysis-update , 1989, IEEE Record of Conference Papers on Cement Industry Technical Conference.

[21]  E. F. Fuchs,et al.  Sensitivity of Electrical Appliances to Harmonics and Fractional Harmonics of the Power System's Voltage. Part II: Television Sets, Induction Watthour Meters and Universal Machines , 1987, IEEE Transactions on Power Delivery.

[22]  M.I.A. Bakar Assessments for the impact of harmonic current distortion of non linear load in power system harmonics , 2008, 2008 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America.

[23]  E. M. Cherry,et al.  Detailed analysis of 3rd-harmonic tuning of television horizontal-deflection circuit , 1970 .

[24]  Prasad Enjeti,et al.  A new method to improve THD and reduce harmonics generated by a three phase diode rectifier type utility interface , 1994, Proceedings of 1994 IEEE Industry Applications Society Annual Meeting.

[25]  H. O. Aintablian,et al.  Harmonic currents generated by personal computers and their effects on the distribution system neutral current , 1993, Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting.

[26]  J.S. Subjak,et al.  Harmonics-causes, effects, measurements and analysis-update , 1989, Conference Record. Industrial and Commercial Power Systems Technical Conference.

[27]  Manuel Castro,et al.  Harmonics in Power Systems , 2009 .

[28]  Davide Fabiani,et al.  The effect of voltage distortion on ageing acceleration of insulation systems under partial discharge activity , 2001 .

[29]  I. E. Portugues,et al.  The influence of personal computer processing modes on line current harmonics , 2003 .

[30]  H. Sharma,et al.  Harmonic impacts of widespread use of CFL lamps on distribution systems , 2011, 2011 IEEE Power and Energy Society General Meeting.

[31]  Azah Mohamed,et al.  Analysis of harmonic emmision from dimmable compact fluorescent lamps , 2011, Proceedings of the 2011 International Conference on Electrical Engineering and Informatics.

[32]  H.S. Athab,et al.  A Cost Effective Method of Reducing Total Harmonic Distortion (THD) in Single-Phase Boost Rectifier , 2007, 2007 7th International Conference on Power Electronics and Drive Systems.