Chronic and low charge injection wireless intraneural stimulation in vivo

Functional stability and in-vivo reliability are significant factors determining the longevity of a neural interface. In this ongoing study, we test the performance of a wireless floating microelectrode array (WFMA) over a period of 143 days. The topography of the microelectrodes has allowed for selective stimulation of different fascicles of the rat sciatic nerve. We confirmed that motor evoked thresholds remain stable over time and that the nerve stimulation charges were within tissue safety limits. Importantly, motor evoked responses were elicited at threshold currents in fully awake animals without causing pain or discomfort. These data validate the use of the WFMA system for intraneural interfacing of peripheral nerves for neuroprosthetic and bioelectronics medical applications.

[1]  Philip R. Troyk,et al.  In-vivo tests of a 16-channel implantable wireless neural stimulator , 2015, 2015 7th International IEEE/EMBS Conference on Neural Engineering (NER).

[2]  Philip R. Troyk,et al.  Potential-biased, asymmetric waveforms for charge-injection with activated iridium oxide (AIROF) neural stimulation electrodes , 2006, IEEE Transactions on Biomedical Engineering.

[3]  Rajmohan Bhandari,et al.  Long-term reliability of Al2O3 and Parylene C bilayer encapsulated Utah electrode array based neural interfaces for chronic implantation , 2014, Journal of neural engineering.

[4]  Patrick A Tresco,et al.  The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skull. , 2007, Journal of biomedical materials research. Part A.

[5]  S. Cogan Neural stimulation and recording electrodes. , 2008, Annual review of biomedical engineering.

[6]  King Chung,et al.  Challenges and Recent Developments in Hearing Aids , 2004, Trends in amplification.

[7]  Philip R. Troyk,et al.  Accelerated-stress reliability evaluation for an encapsulated wireless cortical stimulator , 2014, 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[8]  Mario I. Romero-Ortega,et al.  Chronic sensory-motor activity in behaving animals using regenerative multi-electrode interfaces , 2014, 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[9]  K.J. Otto,et al.  In vitro and in vivo testing of a wireless multichannel stimulating telemetry microsystem , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[10]  S.F. Cogan,et al.  Sputtered iridium oxide films (SIROFs) for low-impedance neural stimulation and recording electrodes , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[11]  P.R. Troyk,et al.  A Multifunctional Neural Electrode Stimulation ASIC using NeuroTalkTM Interface , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[12]  Florian Solzbacher,et al.  Long term in vitro functional stability and recording longevity of fully integrated wireless neural interfaces based on the Utah Slant Electrode Array , 2011, Journal of neural engineering.