On a Two-Unit Standby-Redundant System with Imperfect Switchover

A standby-redundant repairable system having only two units and an imperfect switchover is considered. The Lapace-Stieltjes transform of the distribution of the time to first system faflure (TFSF) and the mean TFSF are derived. Numerical comparisons of the mean TFSF with both perfect and imperfect switching are made. All time distributions, except repair of the main units, are exponential.