False arrhythmia alarm reduction in the intensive care unit using data fusion and machine learning

With aim of reducing the incidence of false critical arrhythmia alarms in intensive care units, a novel data fusion and machine learning algorithm is presented in this article. The 2015 PhysioNet/Computing in Cardiology Challenge database was used in this present algorithm, with each grouped as an asystole (AS), extreme bradycardia (EB), extreme tachycardia (ET), ventricular tachycardia (VT) or ventricular flutter/fibrillation (VF) arrhythmia alarm. A 10-second segment before the onset of the alarm was truncated from available signals, namely electrocardiogram (ECG), arterial blood pressure (ABP), and/or photoplethysmogram (PPG). By first assessing signal quality of available signals, a robust estimation of beat-to-beat intervals could then be derived. Features in heart rate variability (HRV) analysis and ECG parameters such as temporal statistical parameters, spectral analysis results, wavelet transformation coefficients, and complexity measurement etc were extracted and formed a vector. After feature selection through genetic algorithm (GA), a support vector machine (SVM) model was applied to conduct the classification of alarms for the specific arrhythmia type. The overall true positive rate (TPR) of classification algorithm is 93%, with the true negative rate (TNR) 94%. According to the method of performance evaluation in the 2015 Challenge, this algorithm achieved a gross score of 84.4.

[1]  Chih-Jen Lin,et al.  LIBSVM: A library for support vector machines , 2011, TIST.

[2]  A Deshmane,et al.  False arrhythmia alarm suppression using ECG, ABP, and photoplethysmogram , 2009 .

[3]  G. Clifford,et al.  Signal quality and data fusion for false alarm reduction in the intensive care unit. , 2012, Journal of electrocardiology.

[4]  D CliffordGari,et al.  Reducing false alarm rates for critical arrhythmias using the arterial blood pressure waveform , 2008 .

[5]  Qiao Li,et al.  The PhysioNet/Computing in Cardiology Challenge 2015: Reducing false arrhythmia alarms in the ICU , 2015, 2015 Computing in Cardiology Conference (CinC).

[6]  Gari D Clifford,et al.  Multimodal heart beat detection using signal quality indices , 2015, Physiological measurement.

[7]  R.G. Mark,et al.  A signal abnormality index for arterial blood pressure waveforms , 2006, 2006 Computers in Cardiology.

[8]  Mohammad Bagher Shamsollahi,et al.  Life-Threatening Arrhythmia Verification in ICU Patients Using the Joint Cardiovascular Dynamical Model and a Bayesian Filter , 2011, IEEE Transactions on Biomedical Engineering.

[9]  Daniel A Reuter,et al.  Patient monitoring alarms in the ICU and in the operating room , 2013, Critical Care.

[10]  Mohammed Saeed,et al.  Reducing false alarm rates for critical arrhythmias using the arterial blood pressure waveform , 2008, J. Biomed. Informatics.

[11]  Yoel Donchin,et al.  The hostile environment of the intensive care unit , 2002, Current opinion in critical care.

[12]  S. Lawless Crying wolf: False alarms in a pediatric intensive care unit , 1994, Critical care medicine.