Dynamic core length in saturated core fault current limiters

A saturated core fault current limiter (SCFCL) is a non-linear core-reactor where the core is saturated by an external superconducting DC bias source to achieve a low core permeability at nominal AC currents. Fault current levels in the AC coils de-saturate the core and transform it to a higher permeability state, hence limiting the fault current. In this work we describe the transition between saturated and de-saturated states in three SCFCL configurations. The ‘effective core length’, Leff, of the SCFCL, defined as the length of the de-saturated AC core limb, is introduced for exploring this transition as a function of the current, I, in the AC coil. Practically, Leff allows one to see the SCFCL as an inductor with a variable core length, allowing calculations of the impedance of the SCFCL over the whole range of operating currents. The Leff(I) curve is further used to calculate the dynamics of the demagnetization factor in a SCFCL. We show that the strong change in the magnetic induction of a SCFCL at high current is the result of both increasing the effective core length and decreasing the demagnetization factor. The method and results presented here serve as an important tool for comparing between various SCFCL concepts not only by comparing their impedance values at the extreme fault and nominal current conditions but also by providing an insight into the full de-saturation process.

[1]  Y. Wolfus,et al.  Dynamic Desaturation Process in Saturated Cores Fault Current Limiters , 2012, IEEE Transactions on Applied Superconductivity.

[2]  A. Abramovitz,et al.  Survey of Solid-State Fault Current Limiters , 2012, IEEE Transactions on Power Electronics.

[3]  F. Moriconi,et al.  Development and Deployment of Saturated-Core Fault Current Limiters in Distribution and Transmission Substations , 2011, IEEE Transactions on Applied Superconductivity.

[4]  Karen Willcox,et al.  Kinetics and kinematics for translational motions in microgravity during parabolic flight. , 2009, Aviation, space, and environmental medicine.

[5]  Michael Conlon,et al.  Fault current level issues for urban distribution network with high penetration of distributed generation , 2009, 2009 6th International Conference on the European Energy Market.

[6]  Zvi Bar-Haim,et al.  Fault current limiter (FCL) with saturated by superconducting coils cores , 2005 .

[7]  N. Pundak,et al.  Saturated Cores FCL—A New Approach , 2007, IEEE Transactions on Applied Superconductivity.

[8]  G. Fève,et al.  A coherent RC circuit , 2012, Reports on progress in physics. Physical Society.

[9]  Mathias Noe,et al.  High-temperature superconductor fault current limiters: concepts, applications, and development status , 2007 .

[10]  B. Raju,et al.  A Current Limiting Device Using Superconducting D.C. Bias Applications and Prospects , 1982, IEEE Transactions on Power Apparatus and Systems.

[11]  Youguang Guo,et al.  Analysis of Transient Overvoltage in 220 kV Saturated Core HTS FCL , 2011, IEEE Transactions on Magnetics.

[12]  Enric Pardo,et al.  Demagnetizing factors of rectangular prisms and ellipsoids , 2002 .

[13]  Franco Moriconi,et al.  An innovative compact saturable-core HTS Fault Current Limiter - development, testing and application to transmission class networks , 2010, IEEE PES General Meeting.