Simultaneous optical mapping of transmembrane potential and wall motion in isolated, perfused whole hearts.

Optical mapping of cardiac propagation has traditionally been hampered by motion artifact, chiefly due to changes in photodetector-to-tissue registration as the heart moves. We have developed an optical mapping technique to simultaneously record electrical waves and mechanical contraction in isolated hearts. This allows removal of motion artifact from transmembrane potential (V(m)) recordings without the use of electromechanical uncoupling agents and allows the interplay of electrical and mechanical events to be studied at the whole organ level. Hearts are stained with the voltage-sensitive dye di-4-ANEPPS and ring-shaped markers are attached to the epicardium. Fluorescence, elicited on alternate frames by 450 and 505 nm light-emitting diodes, is recorded at 700 frames∕ per second by a camera fitted with a 605 ± 25 nm emission filter. Marker positions are tracked in software. A signal, consisting of the temporally interlaced 450 and 505 nm fluorescence, is collected from the pixels enclosed by each moving ring. After deinterlacing, the 505 nm signal consists of V(m) with motion artifact, while the 450 nm signal is minimally voltage-sensitive and contains primarily artifacts. The ratio of the two signals estimates V(m). Deformation of the tissue enclosed by each set of 3 rings is quantified using homogeneous finite strain.

[1]  Richard A. Gray,et al.  A Novel Approach to Dual Excitation Ratiometric Optical Mapping of Cardiac Action Potentials With Di-4-ANEPPS Using Pulsed LED Excitation , 2011, IEEE Transactions on Biomedical Engineering.

[2]  Distributed activation and deformation in ventricular epicardium: effects of ventricular pacing , 1993, Proceedings of the 15th Annual International Conference of the IEEE Engineering in Medicine and Biology Societ.

[3]  C. Baumgarten,et al.  Swelling-activated chloride channels in cardiac physiology and pathophysiology. , 2003, Progress in biophysics and molecular biology.

[4]  O. Berenfeld,et al.  Altered Right Atrial Excitation and Propagation in Connexin40 Knockout Mice , 2005, Circulation.

[5]  D. Gauthier,et al.  A fiber-based ratiometric optical cardiac mapping channel using a diffraction grating and split detector. , 2007, Biophysical journal.

[6]  R. Ideker,et al.  Effects of heart isolation, voltage-sensitive dye, and electromechanical uncoupling agents on ventricular fibrillation. , 2003, American journal of physiology. Heart and circulatory physiology.

[7]  G. Salama,et al.  Optical Mapping of Repolarization and Refractoriness From Intact Hearts , 1994, Circulation.

[8]  E. McVeigh,et al.  Novel Technique for Cardiac Electromechanical Mapping with Magnetic Resonance Imaging Tagging and an Epicardial Electrode Sock , 2003, Annals of Biomedical Engineering.

[9]  D L Farkas,et al.  Dual-wavelength ratiometric fluorescence measurements of membrane potential. , 1989, Biochemistry.

[10]  Benoit M. Dawant,et al.  Correction of motion artifact in cardiac optical mapping using image registration , 2005, IEEE Transactions on Biomedical Engineering.

[11]  Role of maximum rate of depolarization in predicting action potential duration during ventricular fibrillation. , 2007, American journal of physiology. Heart and circulatory physiology.

[12]  D. DeMets,et al.  Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure. , 2004, The New England journal of medicine.

[13]  N. Reichek,et al.  Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms. , 1989, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[14]  A Garfinkel,et al.  Effects of diacetyl monoxime and cytochalasin D on ventricular fibrillation in swine right ventricles. , 2001, American journal of physiology. Heart and circulatory physiology.

[15]  R. K. Justice,et al.  Ratiometry of transmembrane voltage-sensitive fluorescent dye emission in hearts. , 2000, American journal of physiology. Heart and circulatory physiology.

[16]  M. Weiner,et al.  Cardiac contractile dysfunction during mild coronary flow reductions is due to an altered calcium-pressure relationship in rat hearts. , 1992, The Journal of clinical investigation.

[17]  Lance B Becker,et al.  Resuscitation after cardiac arrest: a 3-phase time-sensitive model. , 2002, JAMA.

[18]  P Suetens,et al.  Regional strain and strain rate measurements by cardiac ultrasound: principles, implementation and limitations. , 2000, European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology.

[19]  I. Efimov,et al.  Application of blebbistatin as an excitation-contraction uncoupler for electrophysiologic study of rat and rabbit hearts. , 2007, Heart rhythm.

[20]  Gavin D Perkins,et al.  European Resuscitation Council Guidelines for Resuscitation 2010 Section 4. Adult advanced life support. , 2010, Resuscitation.

[21]  Frederick J Vetter,et al.  Optical Action Potential Upstroke Morphology Reveals Near-Surface Transmural Propagation Direction , 2005, Circulation research.

[22]  G. Salama,et al.  Optical Imaging of the Heart , 2004, Circulation research.

[23]  W. L. Wilcock,et al.  Properties of All-Dielectric Interference Filters. II. Filters in Parallel Beams of Light Incident Obliquely and in Convergent Beams , 1959 .

[24]  M. Weiner,et al.  Suppression of motion artifacts in fluorescence spectroscopy of perfused hearts. , 1992, The American journal of physiology.

[25]  G Mirra,et al.  An experimental model of sudden death due to low-energy chest-wall impact (commotio cordis) , 1998, The New England journal of medicine.

[26]  A D McCulloch,et al.  Nonhomogeneous analysis of epicardial strain distributions during acute myocardial ischemia in the dog. , 1993, Journal of biomechanics.

[27]  Toshiaki Hisada,et al.  Structural Heterogeneity in the Ventricular Wall Plays a Significant Role in the Initiation of Stretch-Induced Arrhythmias in Perfused Rabbit Right Ventricular Tissues and Whole Heart Preparations , 2010, Circulation research.

[28]  J. Vomdahl,et al.  Electromechanical mapping of the heart. , 2000 .

[29]  Ivo Provaznik,et al.  Characteristics of motion artifacts in cardiac optical mapping studies , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[30]  R. Stewart,et al.  Myocardial microvascular permeability, interstitial oedema, and compromised cardiac function. , 2010, Cardiovascular research.

[31]  L. Axel,et al.  MR imaging of motion with spatial modulation of magnetization. , 1989, Radiology.

[32]  L. Waldman,et al.  Technique for Measuring Regional Two‐Dimensional Finite Strains in Canine Left Ventricle , 1988, Circulation research.

[33]  S. Quintana,et al.  European Resuscitation Council guidelines for resuscitation 2005. , 2006, Resuscitation.

[34]  Viatcheslav Gurev,et al.  Models of stretch-activated ventricular arrhythmias. , 2010, Journal of electrocardiology.

[35]  M. Fogel,et al.  Diastolic biomechanics in normal infants utilizing MRI tissue tagging. , 2000, Circulation.

[36]  A D McCulloch,et al.  Left ventricular epicardial deformation in isolated arrested dog heart. , 1987, The American journal of physiology.

[37]  F. Prinzen,et al.  Relation between regional electrical activation time and subepicardial fiber strain in the canine left ventricle , 1993, Pflügers Archiv.

[38]  Martyn P. Nash,et al.  Modeling cardiac mechano-electrical feedback using reaction-diffusion-mechanics systems , 2009 .

[39]  Robert W. Mills,et al.  Ventricular Filling Slows Epicardial Conduction and Increases Action Potential Duration in an Optical Mapping Study of the Isolated Rabbit Heart , 2003, Journal of cardiovascular electrophysiology.

[40]  A. Savitzky,et al.  Smoothing and Differentiation of Data by Simplified Least Squares Procedures. , 1964 .

[41]  K. Koch,et al.  Electromechanical mapping of the heart. , 2000, Current opinion in cardiology.