Uma Contribuição aos Sistemas de Monitoramento de Integridade Estrutural Baseados na Impedância Eletromecânica

The electromechanical (E/M) impedance technique has been widely studied for the development of Structural Health Monitoring (SHM) systems in various applications. Although there are many studies indicating the effectiveness and feasibility of this technique, some practical issues in real applications yet should be investigated. The electrical impedance measurement, basic stage of the technique, is usually performed by bulky, heavy and expensive instruments; these features are prohibitive for many applications. The selection of the frequency range in which the electrical impedance must be measured to ensure good sensitivity for damage detection is performed by trial and error methods or by methodologies that use measured data in a considerable amount of tests. Furthermore, the design of the transducer is done without theoretical basis, regardless the characteristics of the host structure. In this work, a fast, versatile and low-cost electrical impedance measurement system was developed; the proposed system successfully replaces the conventional instruments. From an equivalent electromechanical circuit, the transducer loading effect due to the host structure was analyzed. The analysis of the loading effect allows the correct design of the transducer according to the host structure for ensure a good performance of the system. The electromechanical circuit was also used to theoretically determine the frequency ranges in which the transducer has good sensitivity and assist in the selection of the suitable frequency range for structural damage detection. All proposed methodologies were validated by experimental tests on aluminum structures and there was a good match between the theoretical and practical results.

[1]  Rune Brincker,et al.  Vibration Based Inspection of Civil Engineering Structures , 1993 .

[2]  Piervincenzo Rizzo,et al.  Influence of the excitation frequency in the electromechanical impedance method for SHM applications , 2009, Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[3]  Daniel J. Inman,et al.  Feasibility of using impedance‐based damage assessment for pipeline structures , 2001 .

[4]  Daniel J. Inman,et al.  Electro-Mechanical Impedance-Based Wireless Structural Health Monitoring Using PCA-Data Compression and k-means Clustering Algorithms , 2008 .

[5]  Victor Giurgiutiu,et al.  A Low-Cost and Field Portable Electromechanical (E/M) Impedance Analyzer for Active Structural Health Monitoring , 2005 .

[6]  A. Ballato,et al.  Modeling piezoelectric and piezomagnetic devices and structures via equivalent networks , 2001, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  Hoon Sohn,et al.  Overview of Piezoelectric Impedance-Based Health Monitoring and Path Forward , 2003 .

[8]  B. Auld,et al.  Multilayer Impedance Matching Schemes for Broadbanding of Water Loaded Piezoelectric Transducers and High Q Electric Resonators , 1975, IEEE Transactions on Sonics and Ultrasonics.

[9]  Dong Sam Ha,et al.  A system-on-board approach for impedance-based structural health monitoring , 2007, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[10]  Suresh Bhalla,et al.  Influence of structure-actuator interactions and temperature on piezoelectric mechatronic signatures for NDE , 2003, Other Conferences.

[11]  Victor Giurgiutiu,et al.  Recent advancements in the electromechanical (E/M) impedance method for structural health monitoring and NDE , 1998, Smart Structures.

[12]  Craig A. Rogers,et al.  Coupled Electro-Mechanical Analysis of Adaptive Material Systems — Determination of the Actuator Power Consumption and System Energy Transfer , 1994 .

[13]  Yaowen Yang,et al.  Sensitivity of PZT Impedance Sensors for Damage Detection of Concrete Structures , 2008, Sensors.

[14]  G. Kossoff The Effects of Backing and Matching on the Performance of Piezoelectric Ceramic Transducers , 1966, IEEE Transactions on Sonics and Ultrasonics.

[15]  Charles R. Farrar,et al.  Sensor Self-diagnosis Using a Modified Impedance Model for Active Sensing-based Structural Health Monitoring , 2009 .

[16]  Daniel J. Inman,et al.  Improving Accessibility of the Impedance-Based Structural Health Monitoring Method , 2004 .

[17]  M. D. da Cunha,et al.  FEM/BEM impedance and power analysis measured LGS SH-SAW devices , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[18]  Constantinos Soutis,et al.  Damage detection in composite materials using frequency response methods , 2002 .

[20]  Daniel J. Inman,et al.  Frequency Range Selection for Impedance-Based Structural Health Monitoring , 2007 .

[21]  J. V. Filho,et al.  Transducer loading effect on the performance of PZT-based SHM systems , 2010, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[22]  Jozue Vieira Filho,et al.  Experimental analysis of the effect of the structure area on the PZT-based SHM systems , 2009 .

[23]  J. V. Filho,et al.  Optimal Frequency Range Selection for PZT Transducers in Impedance-Based SHM Systems , 2010, IEEE Sensors Journal.

[24]  Gary Cloud,et al.  The application of interferometric techniques to the nondestructive inspection of fiber-reinforced materials , 1993 .

[25]  C. Liang,et al.  Truss Structure Integrity Identification Using PZT Sensor-Actuator , 1995 .

[26]  Yaowen Yang,et al.  Influence of loading on the electromechanical admittance of piezoceramic transducers , 2007 .

[27]  Don Berlincourt,et al.  3 – Piezoelectric and Piezomagnetic Materials and Their Function in Transducers , 1964 .

[28]  W. P. Mason Electromechanical transducers and wave filters , 1942 .

[29]  Peter Cawley,et al.  The impedance method of non-destructive inspection , 1984 .

[30]  Victor Giurgiutiu,et al.  Modeling and testing of PZT and PVDF piezoelectric wafer active sensors , 2006 .

[31]  José Viterbo Filho,et al.  A New Impedance Measurement System for PZT-Based Structural Health Monitoring , 2009, IEEE Transactions on Instrumentation and Measurement.

[32]  Hoon Sohn,et al.  A review of structural health monitoring literature 1996-2001 , 2002 .

[33]  Charles R. Farrar,et al.  Piezoelectric Active Sensor Self-Diagnostics Using Electrical Admittance Measurements , 2006 .

[34]  Shirui Wang,et al.  A Circuit Design for Impedance-based Structural Health Monitoring , 2008 .

[35]  Richard E. Martin,et al.  Damage Assessment of Aerospace Structural Components by Impedance Based Health Monitoring , 2005 .