Modal Current and Cumulative Sum Based Fault Detection Approach in Transmission Lines

Abstract In this paper, a simple and fast approach is suggested for fault detection in transmission lines. The proposed technique utilizes a modified cumulative sum approach for a modal current to identify faults. The modal current is derived by proper linear mixing of three-phase currents. Since different types of faults may occur in transmission lines, all three-phase currents should be considered during fault analysis. By converting three-phase currents to a modal current, the processing time is reduced and less memory is needed. In this paper, a modal current is processed instead of three-phase currents. The modified cumulative sum approach presented in this paper is capable of decreasing computational burdens on the digital relay and accelerating the fault detection procedure. The proposed fault detection technique is evaluated in four different systems. Moreover, some real recorded field data were deliberated in the efficiency assessment of the proposed method. The results denote high accuracy and quickness of the proposed approach. Furthermore, the performance of the proposed methodology is compared with some other similar methods from different aspects.

[1]  Almoataz Y. Abdelaziz,et al.  A directional protection scheme during single pole tripping , 2017 .

[2]  Mohammad Amin Jarrahi,et al.  Fault location methodology in DG based distribution networks , 2016, 2016 21st Conference on Electrical Power Distribution Networks Conference (EPDC).

[3]  Rudra Prakash Maheshwari,et al.  Protection of series compensated transmission line: Issues and state of art , 2014 .

[4]  Teymoor Ghanbari,et al.  Fault current limiter versus series reactor , 2017, 2017 IEEE International Conference on Environment and Electrical Engineering and 2017 IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe).

[5]  Satish M. Mahajan,et al.  Detection of Saturation and Reconstruction of the Secondary Current of a CT , 2010 .

[6]  Teymoor Ghanbari,et al.  A fault classification technique for transmission lines using an improved alienation coefficients technique , 2017 .

[7]  P. Dash,et al.  Transmission line distance relaying using a variable window short-time Fourier transform , 2008 .

[8]  Teymoor Ghanbari,et al.  Autocorrelation function-based technique for stator turn-fault detection of induction motor , 2016 .

[9]  Peter W. Sauer,et al.  Power System Dynamics and Stability , 1997 .

[10]  James S. Thorp,et al.  Computer Relaying for Power Systems , 2009 .

[11]  Haidar Samet,et al.  An EMD based fault type identification scheme in transmission line , 2016, 2016 24th Iranian Conference on Electrical Engineering (ICEE).

[12]  Manas Kumar Jena,et al.  Synchrophasors-Assisted IPII-Based Intelligent Relaying for Transmission Lines Including UPFC , 2015 .

[13]  H. Khorashadi-Zadeh,et al.  Transmission Line Fault Detection & Phase Selection using ANN , 2003 .

[14]  Rudra Prakash Maheshwari,et al.  Decision Tree Based Fault Classification Scheme for Protection of Series Compensated Transmission Lines , 2007 .

[15]  Almoataz Y. Abdelaziz,et al.  Critical aspects on wavelet transforms based fault identification procedures in HV transmission line , 2016 .

[16]  D. K. Mohanta,et al.  Fault Classification in Transmission Lines Using Wavelet Multiresolution Analysis , 2016, IEEE Potentials.

[17]  D. Guillen,et al.  Detection and classification of faults in transmission lines using the maximum wavelet singular value and Euclidean norm , 2015 .

[18]  A.K. Pradhan,et al.  A Cumulative Sum-Based Fault Detector for Power System Relaying Application , 2008, IEEE Transactions on Power Delivery.

[19]  H. P. Khincha,et al.  Intelligent Approach for Fault Diagnosis in Power Transmission Systems Using Support Vector Machines , 2007 .

[20]  Pradipta Kishore Dash,et al.  Distance protection of shunt compensated transmission line using a sparse S-transform , 2015 .

[21]  Xiang-Ning Lin,et al.  Novel design of a fast phase selector using correlation analysis , 2005, IEEE Transactions on Power Delivery.

[22]  Vitor Hugo Ferreira,et al.  A survey on intelligent system application to fault diagnosis in electric power system transmission lines , 2016 .

[23]  Richard Gran,et al.  On the Convergence of Random Search Algorithms In Continuous Time with Applications to Adaptive Control , 1970, IEEE Trans. Syst. Man Cybern..

[24]  Reza Adhami,et al.  A Fault Detection and Classification Technique Based on Sequential Components , 2013, IEEE Transactions on Industry Applications.

[25]  Haidar Samet,et al.  Evaluation of digital metering methods used in protection and reactive power compensation of micro-grids , 2016 .

[26]  Aleena Swetapadma,et al.  A Finite-state Machine Based Approach for Fault Detection and Classification in Transmission Lines , 2016 .

[27]  Sukumar Brahma Iterative Fault Location Scheme for a Transmission Line Using Synchronized Phasor Measurements , 2007 .

[28]  Teymoor Ghanbari,et al.  High-speed directional protection based on cross correlation of Fourier transform components of voltage and current , 2016 .

[29]  Haidar Samet,et al.  An ANFIS-Based Fault Classification Approach in Double-Circuit Transmission Line Using Current Samples , 2015, IWANN.

[30]  Ujjaval J. Patel,et al.  Distance Relaying with Power Swing Detection based on Voltage and Reactive Power Sensitivity , 2015 .

[31]  P. B. Dutta Gupta,et al.  A fuzzy logic based fault classification approach using current samples only , 2007 .

[32]  Girish Kumar Singh,et al.  Statistical decision-tree based fault classification scheme for protection of power transmission lines , 2012 .

[33]  Rudra Prakash Maheshwari,et al.  A New Digital Relaying Scheme for Parallel Transmission Line , 2009 .

[34]  Kwok-Wing Chau,et al.  A new image thresholding method based on Gaussian mixture model , 2008, Appl. Math. Comput..

[35]  Subhojit Ghosh,et al.  Low cost microcontroller based fault detector, classifier, zone identifier and locator for transmission lines using wavelet transform and artificial neural network: A hardware co-simulation approach , 2016 .

[36]  N. Otsu A threshold selection method from gray level histograms , 1979 .

[37]  Erik Valdemar Cuevas Jiménez,et al.  A Comparison of Nature Inspired Algorithms for Multi-threshold Image Segmentation , 2013, Expert Syst. Appl..

[38]  Mladen Kezunovic,et al.  Transmission-Line Fault Analysis Using Synchronized Sampling , 2014, IEEE Transactions on Power Delivery.

[39]  F. Namdari,et al.  High-Speed Protection Scheme Based on Initial Current Traveling Wave for Transmission Lines Employing Mathematical Morphology , 2017, IEEE Transactions on Power Delivery.

[40]  Amin Ghaderi,et al.  High impedance fault detection: A review , 2017 .

[41]  F. V. Lopes,et al.  Two-Terminal Traveling-Wave-Based Transmission-Line Protection , 2017, IEEE Transactions on Power Delivery.

[42]  M. M. Eissa,et al.  New high-voltage directional and phase selection protection technique based on real power system data , 2012 .

[43]  Almoataz Y. Abdelaziz,et al.  A novel single end measuring system based fast identification scheme for transmission line faults , 2017 .

[44]  Anamika Yadav,et al.  Backup protection scheme for transmission line compensated with UPFC during high impedance faults and dynamic situations , 2017 .

[45]  Aurobinda Routray,et al.  A Moving Sum Approach for Fault Detection of Power Systems , 2006 .

[46]  Abdul Gafoor Shaik,et al.  A new wavelet based fault detection, classification and location in transmission lines , 2015 .

[47]  Siemens Aktiengesellschaft,et al.  Numerical Distance Protection: Principles and Applications , 1999 .

[48]  Teymoor Ghanbari,et al.  Passive islanding detection scheme based on autocorrelation function of modal current envelope for photovoltaic units , 2017 .