A new polymer gel for magnetic resonance imaging (MRI) radiation dosimetry.

New composition polymer gels, the N-vinylpyrrolidone argon (VIPAR) gels, were developed and investigated as MRI dosimeters. VIPAR gels were irradiated in the dose range of 0-12 Gy by a 6 MV x-ray linear accelerator and MR-scanned in a 1.5 T magnetic resonance imager. A linear relationship was found between absorbed dose and spin spin relaxation rate R2. The dose sensitivity was found to be approximately 0.1 s(-1) Gy(-1) for a gel composition of 4% w/w in N-vinylpyrrolidone, 4% w/w in N,N'-methylene-bisacrylamide, 5% w/w in gelatine type A and 87% w/w in water. This dose sensitivity was stable with time and did not deteriorate even when a boost radiation dose of 2.5 Gy was applied 15 days after the first irradiation. Good reproducibility of these results was observed when a new batch of gels was produced and used for corresponding measurements and analysis.

[1]  J. Rosiak Radiation formation of hydrogels for drug delivery , 1994 .

[2]  C Baldock,et al.  Experimental procedure for the manufacture and calibration of polyacrylamide gel (PAG) for magnetic resonance imaging (MRI) radiation dosimetry. , 1998, Physics in medicine and biology.

[3]  J. Gore,et al.  NMR relaxation enhancement in gels polymerized and cross-linked by ionizing radiation: a new approach to 3D dosimetry by MRI. , 1993, Magnetic resonance imaging.

[4]  J. Rosiak,et al.  Hydrogels for biomedical purposes , 1995 .

[5]  S. Webb,et al.  An investigation into the dosimetry of a nine-field tomotherapy irradiation using BANG-gel dosimetry. , 1998, Physics in medicine and biology.

[6]  I. Constable,et al.  Effect of crosslinked poly(1-vinyl-2-pyrrolidinone) gels on cell growth in static cell cultures. , 1997, Bio-medical materials and engineering.

[7]  S. Baccaro,et al.  Mechanical properties of polyvinylpyrrolidone (PVP) hydrogels undergoing radiation , 1995 .

[8]  J. Rødal,et al.  Measurement of dynamic wedge angles and beam profiles by means of MRI ferrous sulphate gel dosimetry , 1996, Physics in medicine and biology.

[9]  Measurement of radiation dose distributions by NMR imaging , 1984 .

[10]  Phantom dosimeters examined by NMR analysis: a promising technique for 3-D determinations of absorbed dose. , 1997, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[11]  L J Schreiner,et al.  Multiple-site fast exchange model for spin-lattice relaxation in the Fricke-gelatin dosimeter. , 1997, Medical physics.

[12]  J C Gore,et al.  Effects of crosslinking and temperature on the dose response of a BANG polymer gel dosimeter. , 1997, Physics in medicine and biology.

[13]  Radiation dosimetry using nuclear magnetic resonance: an introductory review. , 1990, Physics in medicine and biology.

[14]  J C Gore,et al.  Radiation therapy dosimetry using magnetic resonance imaging of polymer gels. , 1996, Medical physics.

[15]  I J Constable,et al.  Poly(1-vinyl-2-pyrrolidinone) hydrogels as vitreous substitutes: histopathological evaluation in the animal eye. , 1996, Journal of biomaterials science. Polymer edition.

[16]  T. Hellebust,et al.  Determination of 3D dose distribution from intracavitary brachytherapy of cervical cancer by MRI of irradiated ferrous sulphate gel. , 1997, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[17]  O Nalcioglu,et al.  Measurement of three-dimensional radiation dose distributions using MRI. , 1991, Radiation research.

[18]  J C Gore,et al.  Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeter , 1994, Physics in medicine and biology.

[19]  J. Gore,et al.  Measurement of radiation dose distributions by nuclear magnetic resonance (NMR) imaging. , 1984, Physics in medicine and biology.

[20]  M D Evans,et al.  Imaging of HDR brachytherapy dose distributions using NMR Fricke-gelatin dosimetry. , 1994, Magnetic resonance imaging.