Determination of nitrate and nitrite in vegetables by capillary electrophoresis with indirect detection

Abstract Nitrate and nitrite (and some other anions) were determined in vegetables by capillary electrophoresis (CE). The anions were extracted from the vegetables by mixing and diluting the samples with water at moderate temperature. The CE method is divided into two parts: a high-concentration-level method (for nitrate determination) and a low-concentration-level method (for nitrite determination). These CE methods were compared with a reference method (spectrophotometry after Jones reduction: official AOAC reference method for the determination of nitrates in foodstuffs). Parameters such as linearity, detection limit, quantification limit, precision and accuracy of the two techniques were investigated and compared. Both techniques resulted in acceptable linearity within their ranges. The detection limits of the CE methods were sufficiently low for the determination of the anions in vegetable samples. The precision and accuracy of the CE methods were comparable to those of the reference method. The precision was determined by evaluating the repeatability and the time-different intermediate precision, while the accuracy was investigated by comparing the slopes of the standard addition and external calibration lines and by evaluating the agreement between the results obtained with the CE and the reference spectrophotometric methods.

[1]  D. Massart,et al.  Comparison of capillary zone electrophoresis with high-performance liquid chromatography for the determination of additives in foodstuffs. , 1993, Journal of chromatography.

[2]  Kenneth Helrich,et al.  Official methods of analysis of the Association of Official Analytical Chemists , 1990 .

[3]  D. Massart,et al.  Prediction of the migration behaviour of anions in capillary ion analysis , 1994 .

[4]  W. R. Jones,et al.  Optimization of detection sensitivity in the capillary electrophoresis of inorganic anions , 1991 .

[5]  R. Lees,et al.  Laboratory handbook of methods of food analysis , 1971 .

[6]  W. R. Jones,et al.  Controlled changes of selectivity in the separation of ions by capillary electrophoresis , 1991 .

[7]  J. P. de Kleijn,et al.  Determination of nitrite and nitrate in meat products by high-performance liquid chromatography. , 1984, The Analyst.

[8]  D. Pietrzyk,et al.  Determination of nitrite and nitrate in water and food samples by ion interaction chromatography. , 1982, Analytical Chemistry.

[9]  P. Brown,et al.  Factors affecting the separation of inorganic metal cations by capillary electrophoresis , 1992 .

[10]  D. Massart,et al.  Problems in method-comparison studies , 1993 .

[11]  Johanna Smeyers-Verbeke,et al.  The quality coefficient as a tool in decisions about the quality of calibration in graphite furnace atomic absorption spectrometry , 1992 .

[12]  D. Massart,et al.  Determination of alkali and alkaline earth metals in real samples by capillary ion analysis , 1994 .

[13]  K. Ueda,et al.  Determination of nitrite, sulphate, bromide and nitrate in human serum by ion chromatography. , 1989, The Analyst.

[14]  J. Beckers,et al.  Effect of sample stacking on resolution, calibration graphs and pH in capillary zone electrophoresis , 1993 .

[15]  R. Lees Food analysis: Analytical and quality control methods for the food manufacturer and buyer , 1975 .

[16]  D. Massart,et al.  Method development and optimization for the determination of rare earth metal ions by capillary zone electrophoresis , 1993 .