Tissue Equivalence Correction in Silicon Microdosimetry for Protons Characteristic of the LEO Space Environment

The tissue equivalence of solid state silicon detectors in proton radiation fields was determined to improve the radiation protection applications of silicon detectors in aviation and space missions. The study was performed by means of Geant4 simulations. Results are presented showing that a simple c( ~ 0.56) of linear dimensions is adequate to convert experimentally obtained microdosimetric energy deposition spectra in silicon to equivalent microdosimetric energy deposition spectra in water.

[1]  M. Shea,et al.  CREME96: A Revision of the Cosmic Ray Effects on Micro-Electronics Code , 1997 .

[2]  B. Mascialino,et al.  New Developments of the Goodness-of-Fit Statistical Toolkit , 2006, IEEE Transactions on Nuclear Science.

[3]  Anatoly Rosenfeld,et al.  Out-of-field dose equivalents delivered by proton therapy of prostate cancer. , 2007, Medical physics.

[4]  M. Zaider,et al.  Solid State Microdosimetry With Heavy Ions for Space Applications , 2007, IEEE Transactions on Nuclear Science.

[5]  M. Goitein,et al.  A new silicon detector for microdosimetry applications in proton therapy , 1999, 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019).

[6]  T. Koi,et al.  Ion Transport Simulation Using Geant4 Hadronic Physics , 2005 .

[7]  SOI microdosemetry for mixed field radiation protection , 2008 .

[8]  H. Burkhardt,et al.  Geant4 standard electromagnetic package for HEP applications , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[9]  I. Cornelius,et al.  Silicon Microdosimetry in Heterogeneous Materials: Simulation and Experiment , 2006, IEEE Transactions on Nuclear Science.

[10]  P. Bradley,et al.  Tissue equivalence correction for silicon microdosimetry detectors in boron neutron capture therapy. , 1998, Medical physics.

[11]  S. Guatelli,et al.  Geant4 Simulation in a Distributed Computing Environment , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[12]  S. Incerti,et al.  Geant4 developments and applications , 2006, IEEE Transactions on Nuclear Science.

[13]  N. Smirnov Table for Estimating the Goodness of Fit of Empirical Distributions , 1948 .

[14]  A. Heikkinen,et al.  Bertini intra-nuclear cascade implementation in Geant4 , 2003, nucl-th/0306008.

[15]  P. Bradley,et al.  The development of a Novel Silicon Microdosimeter for high LET radiation therapy , 2000 .

[16]  M. Zaider,et al.  Solid state microdosimetry. , 2001, Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms.

[17]  Marco Zaider,et al.  Microdosimetry and Its Applications , 1995 .

[18]  M. Pia,et al.  A goodness-of-fit statistical toolkit , 2004, IEEE Transactions on Nuclear Science.

[19]  A B Rosenfeld,et al.  Performance of silicon microdosimetry detectors in boron neutron capture therapy. , 1999, Radiation research.

[20]  M. Zaider,et al.  Microdosimetry simulations of solar protons within a spacecraft , 2005, IEEE Transactions on Nuclear Science.

[21]  M. Zaider,et al.  Solid state microdosimetry in hadron therapy. , 2002, Radiation protection dosimetry.

[22]  M. Carolan,et al.  Method of Monte Carlo simulation verification in hadron therapy with non-tissue equivalent detectors. , 2006, Radiation protection dosimetry.