Enhancing liver tumor localization accuracy by prior-knowledge-guided motion modeling and a biomechanical model.

Background Pre-treatment liver tumor localization remains a challenging task for radiation therapy, mostly due to the limited tumor contrast against normal liver tissues, and the respiration-induced liver tumor motion. Recently, we developed a biomechanical modeling-based, deformation-driven cone-beam CT estimation technique (Bio-CBCT), which achieved substantially improved accuracy on low-contrast liver tumor localization. However, the accuracy of Bio-CBCT is still affected by the limited tissue contrast around the caudal liver boundary, which reduces the accuracy of the boundary condition that is fed into the biomechanical modeling process. In this study, we developed a motion modeling and biomechanical modeling-guided CBCT estimation technique (MM-Bio-CBCT), to further improve the liver tumor localization accuracy by incorporating a motion model into the CBCT estimation process. Methods MM-Bio-CBCT estimates new CBCT images through deforming a prior high-quality CT or CBCT volume. The deformation vector field (DVF) is solved by iteratively matching the digitally-reconstructed-radiographs (DRRs) of the deformed prior image to the acquired 2D cone-beam projections. Using the same solved DVF, the liver tumor volume contoured on the prior image can be transferred onto the new CBCT image for automatic tumor localization. To maximize the accuracy of the solved DVF, MM-Bio-CBCT employs two strategies for additional DVF optimization: (I) prior-knowledge-guided liver boundary motion modeling with motion patterns extracted from a prior 4D imaging set like 4D-CTs/4D-CBCTs, to improve the liver boundary DVF accuracy; and (II) finite-element-analysis-based biomechanical modeling of the liver volume to improve the intra-liver DVF accuracy. We evaluated the accuracy of MM-Bio-CBCT on both the digital extended-cardiac-torso (XCAT) phantom images and real liver patient images. The liver tumor localization accuracy of MM-Bio-CBCT was evaluated and compared with that of the purely intensity-driven 2D-3D deformation technique, the 2D-3D deformation technique with motion modeling, and the Bio-CBCT technique. Metrics including the DICE coefficient and the center-of-mass-error (COME) were assessed for quantitative evaluation. Results Using limited-view 20 projections for CBCT estimation, the average (± SD) DICE coefficients between the estimated and the 'gold-standard' liver tumors of the XCAT study were 0.57±0.31, 0.78±0.26, 0.83±0.21, and 0.89±0.11 for 2D-3D deformation, 2D-3D deformation with motion modeling, Bio-CBCT and MM-Bio-CBCT techniques, respectively. Using 20 projections for estimation, the patient study yielded average DICE results of 0.63±0.21, 0.73±0.13 and 0.78±0.12, and 0.83±0.09, correspondingly. The MM-Bio-CBCT localized the liver tumor to an average COME of ~2 mm for both the XCAT and the liver patient studies. Conclusions Compared to Bio-CBCT, MM-Bio-CBCT further improves the accuracy of liver tumor localization. MM-Bio-CBCT can potentially be used towards pre-treatment liver tumor localization and intra-treatment liver tumor location verification to achieve substantial radiotherapy margin reduction.

[1]  R. T. Ten Haken,et al.  Radiation-associated liver injury. , 2010, International journal of radiation oncology, biology, physics.

[2]  Robin Shandas,et al.  A microstructurally driven model for pulmonary artery tissue. , 2011, Journal of biomechanical engineering.

[3]  Benjamin J. Ellis,et al.  FEBio: finite elements for biomechanics. , 2012, Journal of biomechanical engineering.

[4]  J. Wang,et al.  Mooney-Rivlin biomechanical modeling of lung with Inhomogeneous material , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[5]  Weiguo Lu,et al.  A simple fixed-point approach to invert a deformation field. , 2007, Medical physics.

[6]  Xuejun Gu,et al.  Simultaneous motion estimation and image reconstruction (SMEIR) for 4D cone-beam CT , 2013, 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC).

[7]  Oliver Blanck,et al.  Lipiodol versus diaphragm in 4D-CBCT-guided stereotactic radiotherapy of hepatocellular carcinomas , 2016, Strahlentherapie und Onkologie.

[8]  Steve B. Jiang,et al.  On a PCA-based lung motion model , 2010, Physics in medicine and biology.

[9]  Timothy D. Solberg,et al.  Scatter correction for cone-beam computed tomography using moving blocker strips: a preliminary study. , 2010 .

[10]  Steve B. Jiang,et al.  Liver motion during cone beam computed tomography guided stereotactic body radiation therapy. , 2012, Medical physics.

[11]  Steve B. Jiang,et al.  Single-Projection Based Volumetric Image Reconstruction and 3D Tumor Localization in Real Time for Lung Cancer Radiotherapy , 2010, MICCAI.

[12]  Chi-Wing Fu,et al.  H-DenseUNet: Hybrid Densely Connected UNet for Liver and Tumor Segmentation From CT Volumes , 2018, IEEE Transactions on Medical Imaging.

[13]  Fang-Fang Yin,et al.  Preliminary clinical evaluation of a 4D-CBCT estimation technique using prior information and limited-angle projections. , 2015, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[14]  T. Hong,et al.  Role and Future Directions of External Beam Radiotherapy for Primary Liver Cancer , 2017, Cancer control : journal of the Moffitt Cancer Center.

[15]  Xiaohu Guo,et al.  Sensitivity of tumor motion simulation accuracy to lung biomechanical modeling approaches and parameters , 2015, Physics in medicine and biology.

[16]  Steve B Jiang,et al.  Implementation and evaluation of various demons deformable image registration algorithms on a GPU. , 2010, Physics in medicine and biology.

[17]  Jing Wang,et al.  A Biomechanical Modeling Guided CBCT Estimation Technique , 2017, IEEE Transactions on Medical Imaging.

[18]  Maria Thor,et al.  Deformable image registration for contour propagation from CT to cone-beam CT scans in radiotherapy of prostate cancer , 2011, Acta oncologica.

[19]  J H Siewerdsen,et al.  Cone-beam computed tomography with a flat-panel imager: initial performance characterization. , 2000, Medical physics.

[20]  Adil Al-Mayah,et al.  Deformable image registration of heterogeneous human lung incorporating the bronchial tree. , 2010, Medical physics.

[21]  Bin Li,et al.  Incorporating biomechanical modeling and deep learning into a deformation-driven liver CBCT reconstruction technique , 2019, Medical Imaging.

[22]  R. Siddon Fast calculation of the exact radiological path for a three-dimensional CT array. , 1985, Medical physics.

[23]  Jialin Peng,et al.  Automatic 3D liver segmentation based on deep learning and globally optimized surface evolution , 2016, Physics in medicine and biology.

[24]  Jing Wang,et al.  High-quality four-dimensional cone-beam CT by deforming prior images. , 2013, Physics in medicine and biology.

[25]  Hui Yan,et al.  Development and clinical evaluation of a three-dimensional cone-beam computed tomography estimation method using a deformation field map. , 2012, International journal of radiation oncology, biology, physics.

[26]  Michael Velec,et al.  Effect of breathing motion on radiotherapy dose accumulation in the abdomen using deformable registration. , 2011, International journal of radiation oncology, biology, physics.

[27]  W. O'Dell,et al.  Modeling liver motion and deformation during the respiratory cycle using intensity-based nonrigid registration of gated MR images. , 2004, Medical physics.

[28]  Fang-Fang Yin,et al.  A technique for estimating 4D-CBCT using prior knowledge and limited-angle projections. , 2013, Medical physics.

[29]  Radhe Mohan,et al.  Audio-visual biofeedback for respiratory-gated radiotherapy: impact of audio instruction and audio-visual biofeedback on respiratory-gated radiotherapy. , 2006, International journal of radiation oncology, biology, physics.

[30]  Xuesong Lu,et al.  Fully automatic liver segmentation combining multi-dimensional graph cut with shape information in 3D CT images , 2018, Scientific Reports.

[31]  F. Yin,et al.  Scatter Reduction and Correction for Dual-Source Cone-Beam CT Using Prepatient Grids , 2016, Technology in cancer research & treatment.

[32]  J. Balter,et al.  Stereotactic body radiation therapy for primary and metastatic liver tumors. , 2013, Translational oncology.

[33]  N. Dubrawsky Cancer statistics , 1989, CA: a cancer journal for clinicians.

[34]  Wang Liang,et al.  A Unified Level Set Framework Combining Hybrid Algorithms for Liver and Liver Tumor Segmentation in CT Images , 2018, BioMed research international.

[35]  Bin Li,et al.  4D liver tumor localization using cone-beam projections and a biomechanical model. , 2019, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[36]  Hao Yan,et al.  A GPU tool for efficient, accurate, and realistic simulation of cone beam CT projections. , 2012, Medical physics.

[37]  S. French,et al.  Metastatic patterns of cancers: results from a large autopsy study. , 2009, Archives of pathology & laboratory medicine.

[38]  Stephen Breen,et al.  Biomechanical-based image registration for head and neck radiation treatment , 2010, Medical Imaging.

[39]  Heinz Handels,et al.  Patient-specific finite element modeling of respiratory lung motion using 4D CT image data. , 2009, Medical physics.