Carbon monoxide from cookstoves in developing countries: 2. Exposure potentials

Abstract In this paper, we estimate carbon monoxide (CO) concentrations and exposures in a well-mixed, hypothetical village kitchen using measured CO emission factors and published typical values for house, fuel, and activity parameters. The estimate was made to compare CO exposure potentials for a range of no-flue fuel/stove combinations. Based upon this quantitative comparison, recommendations were made on CO exposure reduction by fuel/stove switching. If their house conditions and activity patterns are comparable to those typical values assumed in our estimation, people using biomass and coal cookstoves could have daily CO exposures greater than the exposure equivalents of health-based national standards and WHO guidelines.

[1]  Sumeet Saksena,et al.  Patterns of daily exposure to TSP and CO in the Garhwal Himalaya , 1992 .

[2]  Tara C. Kandpal,et al.  Comparison of CO, NO2 and HCHO emissions from biomass combustion in traditional and improved cookstoves , 1994 .

[3]  K. R. Smith,et al.  Indoor air pollution in developing countries. , 1990, World health statistics quarterly. Rapport trimestriel de statistiques sanitaires mondiales.

[4]  Paul J. Lioy,et al.  Assessing total human exposure to contaminants. A multidisciplinary approach , 1990 .

[5]  T. Kawamoto,et al.  Indoor pollution from heating. , 1996, Industrial health.

[6]  Kirk R. Smith,et al.  Indoor Smoke Exposures from Traditional and Improved Cookstoves: Comparisons among Rural Nepali Women , 1986 .

[7]  W. Ott,et al.  A quantitative definition of exposure and related concepts. , 1997, Journal of exposure analysis and environmental epidemiology.

[8]  K. R. Smith,et al.  Hydrocarbon emissions and health risks from cookstoves in developing countries. , 1996, Journal of exposure analysis and environmental epidemiology.

[9]  N. P. Leslie,et al.  Measurements of nitrous acid inside two research houses , 1990 .

[10]  Ken R. Smith Fuel Combustion, Air Pollution Exposure, and Health: The Situation in Developing Countries , 1993 .

[11]  John Zhang,et al.  Carbon monoxide from cookstoves in developing countries: 1. Emission factors , 1999 .

[12]  D. Swift,et al.  Air pollutants and the respiratory tract , 2005 .

[13]  K. R. Smith Indoor Air Quality and the Pollution Transition , 1990 .

[14]  Sandeep Shah,et al.  Characterization and problems of indoor pollution due to cooking stove smoke , 1993 .

[15]  B. Warren Lung Biology in Health and Disease Series , 1993 .

[16]  Kirk R. Smith,et al.  Air pollution and rural biomass fuels in developing countries: A pilot village study in India and implications for research and policy☆ , 1983 .

[17]  Ken R. Smith Biofuels, Air Pollution, and Health , 1988 .

[18]  Michael G. Apte,et al.  Air pollution and the energy ladder in asian cities , 1994 .

[19]  Chandra Venkataraman,et al.  Thermal Performance and Emission Characteristics of Unvented Biomass-burning Cookstoves: A Proposed Standard Method for Evaluation , 1987 .

[20]  Paul J Lioy,et al.  Typical Household Vacuum Cleaners: The Collection Efficiency and Emissions Characteristics for Fine Particles. , 1999, Journal of the Air & Waste Management Association.

[21]  Hans Stymne,et al.  Measuring ventilation rates in the Swedish housing stock , 1994 .

[22]  John Doull,et al.  VIRAL DISEASES: A SYMPOSIUM , 1976, The Ulster Medical Journal.